{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,2]],"date-time":"2026-05-02T13:57:30Z","timestamp":1777730250072,"version":"3.51.4"},"reference-count":7,"publisher":"SAGE Publications","issue":"4","license":[{"start":{"date-parts":[[2018,3,21]],"date-time":"2018-03-21T00:00:00Z","timestamp":1521590400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Interv Neuroradiol"],"published-print":{"date-parts":[[2018,8]]},"abstract":"<jats:sec>\n                    <jats:title>Background and purpose<\/jats:title>\n                    <jats:p>In our previous study, we established the utility of 8-F balloon guide catheters for anterior circulation aneurysms. This study aims to assess the efficacy of the proximal flow control method using 8-F balloon guide catheters for coil deployment into the aneurysms as a novel adjunctive technique for aneurysmal coil embolisation along with local balloon neck remodeling, stent assist and double catheter techniques.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and methods<\/jats:title>\n                    <jats:p>We retrospectively analysed patients who underwent endovascular coiling of anterior circulation aneurysms between August 2013 and December 2017.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Of 206 patients enrolled in this study, the balloon of the guiding catheter was inflated to assist coil deployment in 43 patients (20.9%). In addition, the proximal flow control method found utility in cases with small aneurysms and relatively narrow-necked internal carotid artery. We observed no intraprocedural complications in this study.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>This technique enabled secure coil deployment without navigating another microcatheter or balloon catheter around the aneurysms.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/1591019918763614","type":"journal-article","created":{"date-parts":[[2018,3,22]],"date-time":"2018-03-22T01:14:19Z","timestamp":1521681259000},"page":"375-378","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":11,"title":["Efficacy of the proximal balloon flow control method for endovascular coil embolisation as a novel adjunctive technique: A retrospective analysis"],"prefix":"10.1177","volume":"24","author":[{"given":"Tomotaka","family":"Ohshima","sequence":"first","affiliation":[{"name":"Neuroendovascular Therapy Center, <!---->Aichi Medical University<!---->, Nagakute, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shigeru","family":"Miyachi","sequence":"additional","affiliation":[{"name":"Neuroendovascular Therapy Center, <!---->Aichi Medical University<!---->, Nagakute, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Naoki","family":"Matsuo","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, <!---->Aichi Medical University<!---->, Nagakute, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Reo","family":"Kawaguchi","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, <!---->Aichi Medical University<!---->, Nagakute, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Aichi","family":"Niwa","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, <!---->Aichi Medical University<!---->, Nagakute, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ryuya","family":"Maejima","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, <!---->Aichi Medical University<!---->, Nagakute, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Taiki","family":"Isaji","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, <!---->Aichi Medical University<!---->, Nagakute, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masakazu","family":"Takayasu","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, <!---->Aichi Medical University<!---->, Nagakute, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2018,3,21]]},"reference":[{"key":"e_1_3_3_2_2","first-page":"21","article-title":"The \u201cremodeling technique\u201d in the treatment of wide neck intracranial aneurysms. Angiographic results and clinical follow-up in 56 cases","volume":"3","author":"Moret J","year":"1997","unstructured":"Moret J, Cognard C, Weil A, et al. The \u201cremodeling technique\u201d in the treatment of wide neck intracranial aneurysms. Angiographic results and clinical follow-up in 56 cases. Interv Neuroradiol J Peritherapeutic Neuroradiol Surg Proced Relat Neurosci 1997; 3: 21\u201335.","journal-title":"Interv Neuroradiol J Peritherapeutic Neuroradiol Surg Proced Relat Neurosci"},{"key":"e_1_3_3_3_2","first-page":"1359","article-title":"Endovascular occlusion of wide-necked aneurysms with a new intracranial microstent (Neuroform) and detachable coils","volume":"54","author":"Benitez RP","year":"2004","unstructured":"Benitez RP, Silva MT, Klem J, et al. Endovascular occlusion of wide-necked aneurysms with a new intracranial microstent (Neuroform) and detachable coils. Neuroradiology 2004; 54: 1359\u20131367.","journal-title":"Neuroradiology"},{"key":"e_1_3_3_4_2","first-page":"1176","article-title":"Double microcatheter technique for detachable coil treatment of large, wide-necked intracranial aneurysms","volume":"19","author":"Baxter BW","year":"1998","unstructured":"Baxter BW, Rosso D, Lownie SP. Double microcatheter technique for detachable coil treatment of large, wide-necked intracranial aneurysms. AJNR Am J Neuroradiol 1998; 19: 1176\u20131178.","journal-title":"AJNR Am J Neuroradiol"},{"key":"e_1_3_3_5_2","first-page":"435","article-title":"8-F Balloon guide catheter for embolization of anterior circulation aneurysms: an institutional experience in 152 patients","volume":"79","author":"Ohshima T","year":"2017","unstructured":"Ohshima T, Dash C, Belayev A, et al. 8-F Balloon guide catheter for embolization of anterior circulation aneurysms: an institutional experience in 152 patients. Nagoya J Med Sci 2017; 79: 435\u2013441.","journal-title":"Nagoya J Med Sci"},{"key":"e_1_3_3_6_2","first-page":"1498","article-title":"Procedural complications of coiling of ruptured intracranial aneurysms: incidence and risk factors in a consecutive series of 681 patients","volume":"27","author":"van Rooij WJ","year":"2006","unstructured":"van Rooij WJ, Sluzewski M, Beute GN, et al. Procedural complications of coiling of ruptured intracranial aneurysms: incidence and risk factors in a consecutive series of 681 patients. AJNR Am J Neuroradiol 2006; 27: 1498\u20131501.","journal-title":"AJNR Am J Neuroradiol"},{"key":"e_1_3_3_7_2","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2012-010351"},{"key":"e_1_3_3_8_2","doi-asserted-by":"publisher","DOI":"10.1161\/STROKEAHA.113.002407"}],"container-title":["Interventional Neuroradiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/1591019918763614","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/1591019918763614","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/1591019918763614","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T10:57:58Z","timestamp":1777460278000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/1591019918763614"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,3,21]]},"references-count":7,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2018,8]]}},"alternative-id":["10.1177\/1591019918763614"],"URL":"https:\/\/doi.org\/10.1177\/1591019918763614","relation":{},"ISSN":["1591-0199","2385-2011"],"issn-type":[{"value":"1591-0199","type":"print"},{"value":"2385-2011","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,3,21]]}}}