{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,2]],"date-time":"2026-05-02T14:03:22Z","timestamp":1777730602735,"version":"3.51.4"},"reference-count":29,"publisher":"SAGE Publications","issue":"1","license":[{"start":{"date-parts":[[2020,7,7]],"date-time":"2020-07-07T00:00:00Z","timestamp":1594080000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Interv Neuroradiol"],"published-print":{"date-parts":[[2021,2]]},"abstract":"<jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>PulseRider is a novel self-expanding nickel-titanium (nitinol) stent for treatment of wide-necked aneurysms, which is commonly located at the arterial branches in the brain. This systematic review and meta-analysis aims to assess the efficacy and safety of PulseRider for treatment of wide-necked intracranial aneurysm.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Method<\/jats:title>\n                    <jats:p>We performed a systematic literature search on articles that evaluate the efficacy and safety of PulseRider-assisted coiling of the wide-necked aneurysm from several electronic databases. The primary endpoint was adequate occlusion, defined as Raymond-Roy Class I\u2009+\u2009Raymond-Roy Class II upon immediate angiography and at six-month follow-up.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>There were a total of 157 subjects from six studies. The rate of adequate occlusion on immediate angiography was 90% (95% CI, 85%\u201394%) and 91% (95% CI, 85%\u201396%) at six-month follow-up. Of these, Raymond-Roy Class I can be observed in 48% (95% CI, 41%\u201356%) of aneurysms immediately after coiling, and 64% (95% CI, 55%\u201372%) of aneurysms on six-month follow-up. Raymond-Roy Class II was found in 30% (95% CI, 23%\u201337%) of aneurysms immediately after coiling, and 25% (17\u201333) after six-month follow-up. Complications occur in 5% (95% CI, 1%\u20138%) of the patients. There were three intraoperative aneurysm rupture, three thrombus formation, three procedure-related posterior cerebral artery strokes, one vessel dissection, and one delayed device thrombosis. There was no procedure\/device-related death.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>PulseRider-assisted coiling for treatment of patients with wide-necked aneurysm reached 90% adequate occlusion rate that rises up to 91% at sixth month with 5% complication rate.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/1591019920940521","type":"journal-article","created":{"date-parts":[[2020,7,8]],"date-time":"2020-07-08T01:09:27Z","timestamp":1594170567000},"page":"60-67","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":28,"title":["Efficacy and safety of PulseRider for treatment of wide-necked intracranial aneurysm\u2014A systematic review and meta-analysis"],"prefix":"10.1177","volume":"27","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3998-6551","authenticated-orcid":false,"given":"Raymond","family":"Pranata","sequence":"first","affiliation":[{"name":"Faculty of Medicine, Universitas Pelita Harapan, Tangerang, Indonesia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Emir","family":"Yonas","sequence":"additional","affiliation":[{"name":"Faculty of Medicine, Universitas YARSI, Jakarta, Indonesia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rachel","family":"Vania","sequence":"additional","affiliation":[{"name":"Faculty of Medicine, Universitas Pelita Harapan, Tangerang, Indonesia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Prijo","family":"Sidipratomo","sequence":"additional","affiliation":[{"name":"Department of Radiology, Faculty of Medicine, Universitas Indonesia, Dr. Cipto Mangunkusumo Hospital, Jakarta, Indonesia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Julius","family":"July","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Medical Faculty, Pelita Harapan University, Tangerang, Indonesia"},{"name":"Neuroscience Centre Siloam Hospital, Tangerang, Indonesia"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2020,7,7]]},"reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2017-013223"},{"key":"e_1_3_2_3_2","first-page":"762389","article-title":"Y-stenting for bifurcation aneurysm coil embolization: what is the risk?","volume":"2014","author":"Spiotta AM","year":"2014","unstructured":"Spiotta AM, Lena J, Chaudry MI, et\u00a0al. Y-stenting for bifurcation aneurysm coil embolization: what is the risk? Stroke Res Treat 2014; 2014: 762389.","journal-title":"Stroke Res Treat"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A5900"},{"key":"e_1_3_2_5_2","article-title":"Early postmarket results with PulseRider for treatment of wide-necked intracranial aneurysms: a multicenter experience","author":"Srinivasan VM","unstructured":"Srinivasan VM, Srivatsan A, Spiotta AM, et\u00a0al. Early postmarket results with PulseRider for treatment of wide-necked intracranial aneurysms: a multicenter experience. J Neurosurg. Epub ahead of print 8 November 2019. DOI: 10.3171\/2019.5.JNS1931.","journal-title":"J Neurosurg"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A5599"},{"key":"e_1_3_2_7_2","first-page":"70","article-title":"Wide-necked cerebral artery aneurysms: where do we stand?","author":"McPheeters MJ","year":"2019","unstructured":"McPheeters MJ, Vakharia K, Munich SA, et\u00a0al. Wide-necked cerebral artery aneurysms: where do we stand? Endovasc Today 2019; 70\u201379.","journal-title":"Endovasc Today"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.wneu.2016.12.065"},{"key":"e_1_3_2_9_2","article-title":"Y-stenting versus PulseRider-assisted coiling in the treatment of wide-neck bifurcation aneurysms: role of anatomical features on midterm results","author":"Limbucci N","unstructured":"Limbucci N, Cirelli C, Valente I, et\u00a0al. Y-stenting versus PulseRider-assisted coiling in the treatment of wide-neck bifurcation aneurysms: role of anatomical features on midterm results. Neurosurgery. Epub ahaed of print 3 December 2019. DOI: 10.1093\/neuros\/nyz490.","journal-title":"Neurosurgery"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.3171\/2016.2.JNS152334"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.wneu.2019.04.177"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A3696"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1177\/1591019915590070"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1179\/1743132813Y.0000000234"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A3538"},{"key":"e_1_3_2_16_2","article-title":"Long-term outcomes of wide-necked intracranial bifurcation aneurysms treated with T-stent\u2013assisted coiling","author":"Aydin K","unstructured":"Aydin K, Stracke CP, Barburoglu M, et\u00a0al. Long-term outcomes of wide-necked intracranial bifurcation aneurysms treated with T-stent\u2013assisted coiling. J Neurosurg. Epub ahead of print 6 December 2019. DOI: 10.3171\/2019.9.JNS191733.","journal-title":"J Neurosurg"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1227\/NEU.0000000000000015"},{"key":"e_1_3_2_18_2","doi-asserted-by":"crossref","unstructured":"Pranata R Yonas E Deka H et\u00a0al. Stent-assisted coiling of intracranial aneurysms using a nitinol-based stent (Neuroform Atlas): a systematic review and meta-analysis. Cardiovasc Intervent Radiol 2020; 43(7): 1049\u20131061.","DOI":"10.1007\/s00270-020-02502-9"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2017-013602"},{"key":"e_1_3_2_20_2","doi-asserted-by":"crossref","unstructured":"Zhang S-M Liu L-X Ren P-W et\u00a0al. Effectiveness safety and risk factors of woven endobridge device in the treatment of wide-neck intracranial aneurysms: systematic review and meta-analysis. World Neurosurg 2020; 136: e1\u2013e23.","DOI":"10.1016\/j.wneu.2019.08.023"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.wneu.2019.03.003"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00062-018-0680-6"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.4103\/sni.sni_297_18"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1177\/1591019919858000"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00270-018-2036-7"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00270-019-02307-5"},{"key":"e_1_3_2_27_2","doi-asserted-by":"crossref","unstructured":"Bhogal P Lenz-Habijan T Bannewitz C et\u00a0al. The pCONUS HPC: 30-day and 180-day in vivo biocompatibility results. Cardiovasc Intervent Radiol 2019; 42(7): 1008\u20131015.","DOI":"10.1007\/s00270-019-02202-z"},{"key":"e_1_3_2_28_2","doi-asserted-by":"crossref","unstructured":"Aguilar Perez M AlMatter M Hellstern V et\u00a0al. Use of the pCONus HPC as an adjunct to coil occlusion of acutely ruptured aneurysms: early clinical experience using single antiplatelet therapy. J Neurointerv Surg. Epub ahead of print 2020. DOI: 10.1136\/neurintsurg-2019-0157","DOI":"10.1136\/neurintsurg-2019-015746"},{"key":"e_1_3_2_29_2","doi-asserted-by":"publisher","DOI":"10.3171\/2016.10.JNS161731"},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.1136\/bmjopen-2017-020966"}],"container-title":["Interventional Neuroradiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/1591019920940521","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/1591019920940521","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/1591019920940521","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T10:59:03Z","timestamp":1777460343000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/1591019920940521"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,7,7]]},"references-count":29,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,2]]}},"alternative-id":["10.1177\/1591019920940521"],"URL":"https:\/\/doi.org\/10.1177\/1591019920940521","relation":{},"ISSN":["1591-0199","2385-2011"],"issn-type":[{"value":"1591-0199","type":"print"},{"value":"2385-2011","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,7,7]]}}}