{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,26]],"date-time":"2026-06-26T05:27:35Z","timestamp":1782451655619,"version":"3.54.5"},"reference-count":18,"publisher":"SAGE Publications","issue":"3","license":[{"start":{"date-parts":[[2022,9,16]],"date-time":"2022-09-16T00:00:00Z","timestamp":1663286400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"funder":[{"DOI":"10.13039\/100020501","name":"penumbra","doi-asserted-by":"crossref","award":["n\/a"],"award-info":[{"award-number":["n\/a"]}],"id":[{"id":"10.13039\/100020501","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Interv Neuroradiol"],"published-print":{"date-parts":[[2024,6]]},"abstract":"<jats:sec>\n                    <jats:title>Introduction<\/jats:title>\n                    <jats:p>The purpose of this study was to report our initial experience of using a large-bore (0.096\u2033 inner diameter) access catheter in neurovascular interventions.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Data were retrospectively collected from 5 sites in the US for neurovascular procedures performed using a large-bore access catheter. The effectiveness outcome was technical success, defined as the access catheter's successfully reaching its target vessel without conversion to direct carotid puncture or to a smaller-bore access catheter and successfully completing the intended neurointervention.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>One hundred and thirteen procedures performed in 112 patients were included in this study. The mean age of the patients was 67.5 years (SD 16.2), and about half (49.1%) were female. The most common primary access sites were the femoral (64.6%) or radial (32.7%) artery. Challenging anatomic variations included severe vessel tortuosity (26\/81, 32.1%), type II aortic arch (17\/88, 19.3%), type III aortic arch (14\/88, 15.9%), bovine arch (16\/104, 15.4%), severe angle (&lt;30\u00b0) between the subclavian and target vessel (11\/74, 14.9%), and subclavian loop (7\/79, 8.9%). The median access time to branch view was 18 min (IQR 11-28, N\u2009=\u200975). The technical success rate was 94.7%. Two dissections (1.8%) were related to the large-bore access catheter. Access site complications occurred in 2 patients (1.8%). Four additional symptomatic periprocedural complications not related to the large-bore access catheter occurred (7.1%).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>For neurovascular interventions, a 0.096\u2033 inner diameter access catheter could be used with both femoral and radial arterial approaches, had a high technical success rate, and had a low rate of periprocedural complications.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/15910199221127074","type":"journal-article","created":{"date-parts":[[2022,9,17]],"date-time":"2022-09-17T00:56:45Z","timestamp":1663376205000},"page":"372-379","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":5,"title":["Initial experience of using a large-bore (0.096\u2033 inner diameter) access catheter in neurovascular interventions"],"prefix":"10.1177","volume":"30","author":[{"given":"Robert M","family":"Starke","sequence":"first","affiliation":[{"name":"Department of Neurological Surgery, University of Miami, Miami, FL, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0511-806X","authenticated-orcid":false,"given":"Isaac Josh","family":"Abecassis","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, University of Louisville, Louisville, KY, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vasu","family":"Saini","sequence":"additional","affiliation":[{"name":"Department of Neurology, University of Miami, Miami, FL, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3234-9541","authenticated-orcid":false,"given":"Charles C","family":"Matouk","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery and Department of Radiology & Biomedical Imaging, Yale University, New Haven, CT, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7148-7616","authenticated-orcid":false,"given":"Ameer E","family":"Hassan","sequence":"additional","affiliation":[{"name":"Department of Neurology and Radiology, University of Texas Rio Grande Valley at Valley Baptist Medical Center, Harlingen, TX, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Adnan H","family":"Siddiqui","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, University at Buffalo Neurosurgery, Inc., Buffalo, NY, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Donald F","family":"Frei","sequence":"additional","affiliation":[{"name":"Radiology Imaging Associates, Englewood, CO, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2022,9,16]]},"reference":[{"key":"bibr1-15910199221127074","doi-asserted-by":"publisher","DOI":"10.1177\/19714009211036691"},{"key":"bibr2-15910199221127074","unstructured":"Endovascular Today. Guiding Catheters, https:\/\/evtoday.com\/device-guide\/us\/guiding-catheters (accessed 27 October 2021)."},{"key":"bibr3-15910199221127074","unstructured":"Penumbra Inc. Benchmark BMX96 access system indication for use, https:\/\/www.penumbrainc.com\/neuro-device\/benchmark-bmx96-access-system\/ (accessed 27 October 2021)."},{"key":"bibr4-15910199221127074","unstructured":"Asahi Intec USA Inc. Asahi Fubuki Neurovascular Guide Catheter \/ Neurovascular Guide Catheter Dilator Kit Instructions for Use, https:\/\/asahi-inteccusa-medical.com\/wp-content\/uploads\/2019\/08\/AMK-DT501-Ver.1.00-ASAHI-FUBUKI_US.DOC.pdf (accessed 27 October 2021)."},{"key":"bibr5-15910199221127074","unstructured":"MIVI Neuroscience Inc. Super 90 8F Guide Catheter, https:\/\/www.mivineuro.com\/mi-axus-super-90-guide-catheter (accessed 27 October 2021)."},{"key":"bibr6-15910199221127074","unstructured":"Stryker Corp. AXS infinity LS plus long sheath indications for use. https:\/\/www.stryker.com\/content\/dam\/stryker\/neurovascular\/products\/axs-infinity-ls-plus\/resources\/AXS-Infinity-LS-Plus_DFU_US_Jun18.pdf (accessed 30 December 2021)."},{"key":"bibr7-15910199221127074","doi-asserted-by":"publisher","DOI":"10.1016\/j.ahj.2008.09.010"},{"key":"bibr8-15910199221127074","doi-asserted-by":"publisher","DOI":"10.3389\/fneur.2021.578446"},{"key":"bibr9-15910199221127074","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2017-013184"},{"key":"bibr10-15910199221127074","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A6748"},{"key":"bibr11-15910199221127074","doi-asserted-by":"publisher","DOI":"10.1177\/19714009211041520"},{"key":"bibr12-15910199221127074","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2020-016448"},{"key":"bibr13-15910199221127074","doi-asserted-by":"publisher","DOI":"10.1016\/j.wneu.2018.08.207"},{"key":"bibr14-15910199221127074","doi-asserted-by":"publisher","DOI":"10.1016\/j.clineuro.2021.106510"},{"key":"bibr15-15910199221127074","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2021-017739"},{"key":"bibr16-15910199221127074","doi-asserted-by":"publisher","DOI":"10.1161\/STROKEAHA.119.025811"},{"key":"bibr17-15910199221127074","doi-asserted-by":"publisher","DOI":"10.1177\/1591019920950889"},{"key":"bibr18-15910199221127074","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2021.104459"}],"container-title":["Interventional Neuroradiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/15910199221127074","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/15910199221127074","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/15910199221127074","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T10:59:20Z","timestamp":1777460360000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/15910199221127074"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,9,16]]},"references-count":18,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2024,6]]}},"alternative-id":["10.1177\/15910199221127074"],"URL":"https:\/\/doi.org\/10.1177\/15910199221127074","relation":{},"ISSN":["1591-0199","2385-2011"],"issn-type":[{"value":"1591-0199","type":"print"},{"value":"2385-2011","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,9,16]]}}}