{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T06:02:00Z","timestamp":1792735320777,"version":"4.5.0"},"reference-count":22,"publisher":"SAGE Publications","issue":"4","license":[{"start":{"date-parts":[[2024,2,28]],"date-time":"2024-02-28T00:00:00Z","timestamp":1709078400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"},{"start":{"date-parts":[[2024,2,28]],"date-time":"2024-02-28T00:00:00Z","timestamp":1709078400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Interv Neuroradiol"],"published-print":{"date-parts":[[2026,8]]},"abstract":"<jats:sec>\n                    <jats:title>Introduction<\/jats:title>\n                    <jats:p>Superbore 0.088\u2033 catheters provide a platform for optimizing aspiration efficiency and flow control during stroke mechanical thrombectomy procedures. New superbore catheters have the distal flexibility necessary to navigate complex neurovascular anatomy while providing the proximal support of traditional 8F catheters. The safety and feasibility of Zoom 88\u2122 superbore angled-tip catheters in the middle cerebral artery (MCA) segments smaller than the catheter diameter have not been previously described.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Twenty consecutive cases of acute MCA mechanical thrombectomy were retrospectively identified from the senior authors\u2019 prospectively maintained Institutional Review Board-approved database, in which the Zoom 88 (Imperative Care, Campbell, CA) catheter was successfully navigated to at least the M1 segment. Patient demographics, procedural details, and periprocedural information were analyzed. Rates and averages (standard errors) are generally reported.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>The average National Institutes of Health Stroke Scale at presentation and age were 15\u2009\u00b1\u20092 and 73\u2009\u00b1\u20093 years, respectively. The M1 and M2 occlusions were evenly distributed. The average M1 measurements before thrombectomy ranged from 2.36\u2009\u00b1\u20090.07\u2005mm proximally to 2.00\u2009\u00b1\u20090.11\u2005mm distally, and after thrombectomy, they ranged from 2.34\u2009\u00b1\u20090.07\u2005mm proximally to 1.97\u2009\u00b1\u20090.10\u2005mm distally. First-pass modified thrombolysis in cerebral infarction (mTICI) 2C\/3 recanalization was achieved in 40% of cases, and final mTICI 2C\/3 recanalization was achieved in 90% of cases. A single case of mild vasospasm was managed with verapamil. No hemorrhagic or periprocedural complications were noted.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Superbore 0.088\u2033 catheters with flexible distal segments can be safely navigated to the MCA to augment mechanical thrombectomy even when the MCA segment is smaller than the catheter.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/15910199241229198","type":"journal-article","created":{"date-parts":[[2024,2,28]],"date-time":"2024-02-28T22:17:05Z","timestamp":1709158625000},"page":"1881-1887","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":15,"title":["Feasibility of super-bore 0.088\u2033 mechanical thrombectomy in M1 vessels smaller than 8 French: Experience in 20 consecutive cases"],"prefix":"10.1177","volume":"32","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1075-0764","authenticated-orcid":false,"given":"Jessica K","family":"Campos","sequence":"first","affiliation":[{"name":"University of California Irvine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5773-1619","authenticated-orcid":false,"given":"Benjamen M","family":"Meyer","sequence":"additional","affiliation":[{"name":"University of Arizona, College of Medicine, Tucson, AZ, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Muhammad Waqas","family":"Khan","sequence":"additional","affiliation":[{"name":"Carondelet Neurological Institute, St. Joseph's Hospital, Tucson, AZ, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fahad J","family":"Laghari","sequence":"additional","affiliation":[{"name":"Carondelet Neurological Institute, St. Joseph's Hospital, Tucson, AZ, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David A","family":"Zarrin","sequence":"additional","affiliation":[{"name":"University of California Los Angeles, David Geffen School of Medicine, Los Angeles, CA, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jonathan","family":"Collard de Beaufort","sequence":"additional","affiliation":[{"name":"College of Arts and Science, Syracuse University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gizal","family":"Amin","sequence":"additional","affiliation":[{"name":"Carondelet Neurological Institute, St. Joseph's Hospital, Tucson, AZ, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kiarash","family":"Golshani","sequence":"additional","affiliation":[{"name":"University of California Irvine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthew T","family":"Bender","sequence":"additional","affiliation":[{"name":"University of Rochester"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Geoffrey P","family":"Colby","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, University of California Los Angeles, Los Angeles, CA, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Li-Mei","family":"Lin","sequence":"additional","affiliation":[{"name":"Carondelet Neurological Institute, St. Joseph's Hospital, Tucson, AZ, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexander L","family":"Coon","sequence":"additional","affiliation":[{"name":"Carondelet Neurological Institute, St. Joseph's Hospital, Tucson, AZ, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2024,2,28]]},"reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.5114\/amsad.2021.107820"},{"key":"e_1_3_2_3_2","first-page":"1","volume-title":"StatPearls [Internet]","author":"Baig MU","year":"2023","unstructured":"Baig MU, Bodle J. Thrombolytic therapy. [Updated 2022 Sep 8]. In: StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2023. 1\u20138. Available from: https:\/\/www.ncbi.nlm.nih.gov\/books\/NBK557411\/."},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.3389\/fneur.2021.759759"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1177\/15910199231170283"},{"key":"e_1_3_2_6_2","first-page":"486","article-title":"The penumbra 5MAX ACE catheter is safe, efficient, and cost saving as a primary mechanical thrombectomy device for large vessel occlusions in acute ischemic stroke","volume":"16","author":"Vidal GA","year":"2016","unstructured":"Vidal GA, Milburn JM. The penumbra 5MAX ACE catheter is safe, efficient, and cost saving as a primary mechanical thrombectomy device for large vessel occlusions in acute ischemic stroke. Ochsner J 2016; 16: 486\u2013491.","journal-title":"Ochsner J"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.wneu.2019.06.120"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1177\/15910199221107438"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.4103\/0972-2327.144289"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1161\/STROKEAHA.111.670463"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1177\/15910199221084481"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2014-011298"},{"key":"e_1_3_2_13_2","article-title":"Impact of aspiration catheter size on clinical outcomes in aspiration thrombectomy [published online ahead of print, 2022 Aug 2]","volume":"15","author":"Schartz D","year":"2023","unstructured":"Schartz D, Ellens N, Kohli GS, et al. Impact of aspiration catheter size on clinical outcomes in aspiration thrombectomy [published online ahead of print, 2022 Aug 2]. J Neurointerv Surg. 2023;15:e111\u2013e116.","journal-title":"J Neurointerv Surg"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1055\/s-0029-1242200"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2011-010256"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A6132"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2017-013184"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1177\/15910199221084483"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2021-017341"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2020-016780.rep"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1177\/1591019920982219"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2022-018806"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(19)30297-1"}],"container-title":["Interventional Neuroradiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/15910199241229198","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/15910199241229198","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/15910199241229198","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,8]],"date-time":"2026-08-08T04:46:29Z","timestamp":1786164389000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/15910199241229198"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,2,28]]},"references-count":22,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2026,8]]}},"alternative-id":["10.1177\/15910199241229198"],"URL":"https:\/\/doi.org\/10.1177\/15910199241229198","relation":{},"ISSN":["1591-0199","2385-2011"],"issn-type":[{"value":"1591-0199","type":"print"},{"value":"2385-2011","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,2,28]]}}}