{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,8]],"date-time":"2026-08-08T05:42:38Z","timestamp":1786167758448,"version":"build-2736575974"},"reference-count":38,"publisher":"SAGE Publications","issue":"4","license":[{"start":{"date-parts":[[2024,6,14]],"date-time":"2024-06-14T00:00:00Z","timestamp":1718323200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Interv Neuroradiol"],"published-print":{"date-parts":[[2026,8]]},"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Intracranial dissecting aneurysms present a challenging subset linked to considerable morbidity and mortality, necessitating effective therapeutic strategies to prevent complications. Traditional treatments face technical limitations, while emerging endovascular modalities like stent-assisted coiling, multiple stenting, and flow-diverting devices (FDDs) offer promise in reducing periprocedural risks and enhancing patient outcomes. The aim of this study is to compare the safety and efficacy outcomes of endovascular treatment for intracranial dissecting aneurysms using FDDs versus stents (with or without coiling).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A systematic review and meta-analysis were conducted following established guidelines. The search included PubMed, Scopus, Web of Science, and Embase databases up to July 30, 2023. Eligible studies reporting outcomes of interest in both FDD and stent-treated groups were included, and the data was extracted and analyzed using STATA software.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Six studies were analyzed, involving 131 patients in the FDD group and 199 patients in the stent group. The pooled rates for favorable functional outcomes (86.8% vs. 86%), mortality (3.9% vs. 6%), adequate occlusion (79.7% vs. 86.3%), aneurysm recurrence (1.3% vs. 13.3%), in-stent stenosis\/thrombosis (7% vs. 6.9%), ischemic events\/infarctions (6.7% vs. 7.8%), retreatment (7% vs. 8.6%), and technical success (100% vs. 98.7%) were comparable in individuals treated with FDDs and stents (p\u2009&gt;\u20090.05 in all cases). Additionally, complete occlusion rates were not significantly different between FDD (62.7%) and stent-treated patients (75.2%) (p\u2009=\u20090.06). However, after excluding one study in a leave-one-out analysis of the random effects meta-analysis, a significant difference in the pooled rates of this outcome was observed between the FDD (59.2%) and stent (75.2%) groups (p\u2009=\u20090.034).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>FDDs present a promising approach for the treatment of intracranial dissecting aneurysms, yielding outcomes that are roughly comparable to stent-based methods. However, the absence of randomized trials and data limitations highlight the need for further research to enhance treatment strategies.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/15910199241262070","type":"journal-article","created":{"date-parts":[[2024,6,14]],"date-time":"2024-06-14T04:12:30Z","timestamp":1718338350000},"page":"1669-1679","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":8,"title":["Comparative meta-analysis of endovascular strategies for intracranial dissecting aneurysms: Flow diverters versus stents with or without coiling"],"prefix":"10.1177","volume":"32","author":[{"given":"Melika","family":"Amoukhteh","sequence":"first","affiliation":[{"name":"Mayo Clinic"},{"name":"Department of Radiology, Keck School of Medicine, University of Southern California (USC), Los Angeles, CA, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0529-5341","authenticated-orcid":false,"given":"Amir","family":"Hassankhani","sequence":"additional","affiliation":[{"name":"Mayo Clinic"},{"name":"Department of Radiology, Keck School of Medicine, University of Southern California (USC), Los Angeles, CA, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Payam","family":"Jannatdoust","sequence":"additional","affiliation":[{"name":"Mayo Clinic"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Parya","family":"Valizadeh","sequence":"additional","affiliation":[{"name":"Mayo Clinic"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5629-3023","authenticated-orcid":false,"given":"Sherief","family":"Ghozy","sequence":"additional","affiliation":[{"name":"Mayo Clinic"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6243-9495","authenticated-orcid":false,"given":"Cem","family":"Bilgin","sequence":"additional","affiliation":[{"name":"Mayo Clinic"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8495-0040","authenticated-orcid":false,"given":"David F","family":"Kallmes","sequence":"additional","affiliation":[{"name":"Mayo Clinic"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2024,6,14]]},"reference":[{"key":"e_1_3_3_2_2","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2020-017089"},{"key":"e_1_3_3_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.wneu.2023.04.040"},{"key":"e_1_3_3_4_2","doi-asserted-by":"publisher","DOI":"10.1177\/159101991001600206"},{"key":"e_1_3_3_5_2","doi-asserted-by":"publisher","DOI":"10.1136\/jnnp-2015-312020"},{"key":"e_1_3_3_6_2","doi-asserted-by":"publisher","DOI":"10.2174\/1573405613666170403102235"},{"key":"e_1_3_3_7_2","doi-asserted-by":"publisher","DOI":"10.1177\/1971400919861406"},{"key":"e_1_3_3_8_2","doi-asserted-by":"publisher","DOI":"10.3389\/fneur.2022.919866"},{"key":"e_1_3_3_9_2","doi-asserted-by":"publisher","DOI":"10.21037\/qims-22-970"},{"key":"e_1_3_3_10_2","doi-asserted-by":"publisher","DOI":"10.3389\/fneur.2022.914878"},{"key":"e_1_3_3_11_2","doi-asserted-by":"publisher","DOI":"10.1080\/17434440.2019.1575725"},{"key":"e_1_3_3_12_2","doi-asserted-by":"publisher","DOI":"10.1177\/1591019919830215"},{"key":"e_1_3_3_13_2","first-page":"321","article-title":"Endovascular management of carotid and vertebral artery dissections with new generation double-mesh stent and protection systems\u2014single-center early and midterm results","volume":"15","author":"Latacz P","year":"2019","unstructured":"Latacz P, Simka M, Brzegowy P, et al. Endovascular management of carotid and vertebral artery dissections with new generation double-mesh stent and protection systems\u2014single-center early and midterm results. Postepy Kardiol Interwencyjnej 2019; 15: 321\u2013327.","journal-title":"Postepy Kardiol Interwencyjnej"},{"key":"e_1_3_3_14_2","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pmed.1000097"},{"key":"e_1_3_3_15_2","doi-asserted-by":"publisher","DOI":"10.1177\/159101991001600204"},{"key":"e_1_3_3_16_2","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2014-011258"},{"key":"e_1_3_3_17_2","doi-asserted-by":"crossref","unstructured":"Tufanaru C Munn Z Aromataris E et al. Chapter 3: systematic reviews of effectiveness. In: Aromataris E Munn Z (eds). JBI Manual for Evidence Synthesis. 2020. Available at: https:\/\/synthesismanual.jbi.global","DOI":"10.46658\/JBIRM-17-03"},{"key":"e_1_3_3_18_2","volume-title":"GRADE handbook for grading quality of evidence and strength of recommendations. Updated October 2013","author":"Sch\u00fcnemann H","year":"2013","unstructured":"Sch\u00fcnemann H, Bro\u017cek J, Guyatt G, et al. GRADE handbook for grading quality of evidence and strength of recommendations. Updated October 2013. The GRADE Working Group, 2013. Available at: https:\/\/guidelinedevelopment.org\/handbook."},{"key":"e_1_3_3_19_2","unstructured":"GRADEpro GDT: GRADEpro Guideline development tool [Software]. McMaster University and Evidence Prime 2024. Available at: https:\/\/gradepro.org."},{"key":"e_1_3_3_20_2","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.327.7414.557"},{"key":"e_1_3_3_21_2","article-title":"Chapter 13: assessing risk of bias due to missing results in a synthesis. In: Higgins JPT, Thomas J, Chandler J, Cumpston M, Li T, Page MJ, Welch VA (eds.). Cochrane Handbook for Systematic Reviews of Interventions version 6.4 (updated August 2023)","author":"Page MJ","year":"2023","unstructured":"Page MJ, Higgins JPT, Sterne JAC. Chapter 13: assessing risk of bias due to missing results in a synthesis. In: Higgins JPT, Thomas J, Chandler J, Cumpston M, Li T, Page MJ, Welch VA (eds.). Cochrane Handbook for Systematic Reviews of Interventions version 6.4 (updated August 2023). Cochrane 2023. Available from: www.training.cochrane.org\/handbook","journal-title":"Cochrane"},{"key":"e_1_3_3_22_2","doi-asserted-by":"publisher","DOI":"10.3171\/jns.1997.87.2.0141"},{"key":"e_1_3_3_23_2","doi-asserted-by":"publisher","DOI":"10.3171\/JNS\/2008\/108\/6\/1104"},{"key":"e_1_3_3_24_2","doi-asserted-by":"publisher","DOI":"10.1227\/01.neu.0000306110.55174.30"},{"key":"e_1_3_3_25_2","first-page":"1861","article-title":"Saccular aneurysms on straight and curved vessels are subject to different hemodynamics: implications of intravascular stenting","volume":"27","author":"Meng H","year":"2006","unstructured":"Meng H, Wang Z, Kim M, et al. Saccular aneurysms on straight and curved vessels are subject to different hemodynamics: implications of intravascular stenting. AJNR Am J Neuroradiol 2006; 27: 1861\u20131865.","journal-title":"AJNR Am J Neuroradiol"},{"key":"e_1_3_3_26_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.wneu.2016.11.118"},{"key":"e_1_3_3_27_2","doi-asserted-by":"publisher","DOI":"10.1177\/15910199221095972"},{"key":"e_1_3_3_28_2","doi-asserted-by":"publisher","DOI":"10.1179\/016164102101200014"},{"key":"e_1_3_3_29_2","doi-asserted-by":"publisher","DOI":"10.1177\/15910199221091645"},{"key":"e_1_3_3_30_2","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2016-012969"},{"key":"e_1_3_3_31_2","doi-asserted-by":"publisher","DOI":"10.1093\/neuros\/nyz324"},{"key":"e_1_3_3_32_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.wneu.2018.06.029"},{"key":"e_1_3_3_33_2","doi-asserted-by":"publisher","DOI":"10.3171\/2009.2.JNS081418"},{"key":"e_1_3_3_34_2","doi-asserted-by":"publisher","DOI":"10.3171\/2013.7.JNS122178"},{"key":"e_1_3_3_35_2","doi-asserted-by":"publisher","DOI":"10.3171\/2017.3.FOCUS1742"},{"key":"e_1_3_3_36_2","doi-asserted-by":"publisher","DOI":"10.1177\/15910199231207550"},{"key":"e_1_3_3_37_2","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2018-014363"},{"key":"e_1_3_3_38_2","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.a.36514"},{"key":"e_1_3_3_39_2","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2020-016294"}],"container-title":["Interventional Neuroradiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/15910199241262070","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/15910199241262070","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/15910199241262070","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,8]],"date-time":"2026-08-08T04:49:36Z","timestamp":1786164576000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/15910199241262070"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,6,14]]},"references-count":38,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2026,8]]}},"alternative-id":["10.1177\/15910199241262070"],"URL":"https:\/\/doi.org\/10.1177\/15910199241262070","relation":{},"ISSN":["1591-0199","2385-2011"],"issn-type":[{"value":"1591-0199","type":"print"},{"value":"2385-2011","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,6,14]]}}}