{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,21]],"date-time":"2026-07-21T20:30:42Z","timestamp":1784665842088,"version":"3.55.0"},"reference-count":6,"publisher":"SAGE Publications","issue":"6","license":[{"start":{"date-parts":[[2024,9,28]],"date-time":"2024-09-28T00:00:00Z","timestamp":1727481600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Interv Neuroradiol"],"published-print":{"date-parts":[[2024,12]]},"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Cardiac implantable electronic device (CIED) generally excludes patients from undergoing fixed, high-field magnetic resonance imaging (MRI). Acute ischemic stroke patients undergo MRI as a standard part of an assessment of infarct burden. The use of a portable MRI scanner may be useful in patients who have contraindications to high-field MRI. We present the first case of a patient with a CIED who required an endovascular thrombectomy (EVT) for large vessel occlusion. She underwent a low-field MRI in the operating room with the Hyperfine portable system.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Case<\/jats:title>\n                    <jats:p>The patient is an 80-year-old female status post-CIED, on Eliquis who presented with an acute ischemic stroke. Her National Institutes of Health Stroke Scale (NIHSS) of 8. Imaging demonstrated a left M2 occlusion on computed tomography angiogram (CTA) of the head and neck. No lytics were used due to concomitant gastrointestinal bleed. While, admitted, her NIHSS increased to 15. A subsequent CTA demonstrated a left internal carotid artery terminus and M1 occlusion. She underwent EVT with thrombolysis in cerebral infarction (TICI) 3 revascularization. An MRI was performed intraoperatively using a Hyperfine system, which is a low-field, portable MRI, to assess infarct volume.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Hyperfine Swoop brain MRI may be safe for use in patients with contraindications to high-field MRI scans. Continued technological refinement will improve the quality of diffusion-weighted imaging. Larger studies will be required to generalize Hyperfine MRI-based imaging for patients with devices that exclude them from high-field imaging.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/15910199241286756","type":"journal-article","created":{"date-parts":[[2024,9,28]],"date-time":"2024-09-28T09:33:28Z","timestamp":1727516008000},"page":"862-865","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":3,"title":["Utilizing a portable magnetic resonance imaging (MRI) in the setting of an acute ischemic stroke in a patient with a cardiac implantable electronic device"],"prefix":"10.1177","volume":"30","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9735-7211","authenticated-orcid":false,"given":"Mayur S.","family":"Patel","sequence":"first","affiliation":[{"name":"Department of Neurosurgery, The Ohio State University Wexner Medical Center, Columbus, OH, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nicholas","family":"Mannix","sequence":"additional","affiliation":[{"name":"Department of Neurology, The Ohio State University Wexner Medical Center, Columbus, OH, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Arianna","family":"Carfora","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, The Ohio State University Wexner Medical Center, Columbus, OH, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shahid M.","family":"Nimjee","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, The Ohio State University Wexner Medical Center, Columbus, OH, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2024,9,28]]},"reference":[{"key":"bibr1-15910199241286756","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.23595"},{"key":"bibr2-15910199241286756","volume-title":"Pacemaker","author":"Puette JA","year":"2024"},{"key":"bibr3-15910199241286756","doi-asserted-by":"crossref","first-page":"12","DOI":"10.25259\/SNI_1002_2022","volume":"14","author":"Altaf A","year":"2023","journal-title":"Surg Neurol Int"},{"key":"bibr4-15910199241286756","doi-asserted-by":"publisher","DOI":"10.1161\/STROKEAHA.122.040073"},{"key":"bibr5-15910199241286756","first-page":"670","volume":"43","author":"Chetcuti K","year":"2022","journal-title":"AJNR Am J Neuroradiol"},{"key":"bibr6-15910199241286756","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-022-09760-2"}],"container-title":["Interventional Neuroradiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/15910199241286756","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/15910199241286756","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/15910199241286756","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T10:56:26Z","timestamp":1777460186000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/15910199241286756"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,9,28]]},"references-count":6,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2024,12]]}},"alternative-id":["10.1177\/15910199241286756"],"URL":"https:\/\/doi.org\/10.1177\/15910199241286756","relation":{},"ISSN":["1591-0199","2385-2011"],"issn-type":[{"value":"1591-0199","type":"print"},{"value":"2385-2011","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,9,28]]}}}