{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,5]],"date-time":"2026-05-05T01:12:42Z","timestamp":1777943562766,"version":"3.51.4"},"reference-count":23,"publisher":"SAGE Publications","issue":"4","license":[{"start":{"date-parts":[[2016,7,10]],"date-time":"2016-07-10T00:00:00Z","timestamp":1468108800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Vascular"],"published-print":{"date-parts":[[2016,8]]},"abstract":"<jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>In the present study, 50 EVAS procedures were evaluated in regard to primary (survival and technical success) and secondary (device-related complications) events of interest.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>The single center study was conducted from July 2013 to August 2014 with prospective collection of the clinical data. The clinical results were controlled by CT angiography and contrast-enhanced ultrasound .<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>The technical success was 98% and the 30-day mortality 4%. One (2%) patient died from multisystem organ failure and another patient from an intracranial bleeding, respectively. One patient (2%) suffered from a device-related aneurysm rupture. During early follow-up, one (2%) patient developed an endoleak type II, while three (6%) patients suffered from a partial endograft limb thrombosis. Overall, a secondary intervention was necessary in six (12%) patients.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>With the Nellix EVAS system, a high primary technical success of 98% was achieved; one (2%) patient developed an endoleak type II which did not require secondary intervention. Those promising results are contrasted by a substantial rate of endograft limb thromboses (8%) and one (2%) intraoperative aneurysm rupture. Further studies are needed to assess the durability of the Nellix stentgraft and the occurrence of device-related complications.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/1708538115605430","type":"journal-article","created":{"date-parts":[[2015,10,20]],"date-time":"2015-10-20T20:12:09Z","timestamp":1445371929000},"page":"339-347","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":29,"title":["Early experience with the new endovascular aneurysm sealing system Nellix: First clinical results after 50 implantations"],"prefix":"10.1177","volume":"24","author":[{"given":"Sebastian","family":"Zerwes","sequence":"first","affiliation":[{"name":"Klinikum Augsburg, Vascular surgery, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zmarai","family":"Nurzai","sequence":"additional","affiliation":[{"name":"Klinikum Augsburg, Vascular surgery, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Giesbert","family":"Leissner","sequence":"additional","affiliation":[{"name":"Klinikum Augsburg, Radiology, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thomas","family":"Kroencke","sequence":"additional","affiliation":[{"name":"Klinikum Augsburg, Radiology, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hans-Kees","family":"Bruijnen","sequence":"additional","affiliation":[{"name":"Klinikum Augsburg, Vascular surgery, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rudolf","family":"Jakob","sequence":"additional","affiliation":[{"name":"Klinikum Augsburg, Vascular surgery, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Klaus","family":"Woelfle","sequence":"additional","affiliation":[{"name":"Klinikum Augsburg, Vascular surgery, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2016,7,10]]},"reference":[{"key":"bibr1-1708538115605430","doi-asserted-by":"publisher","DOI":"10.1007\/BF02015271"},{"key":"bibr2-1708538115605430","first-page":"93","volume":"33","author":"Volodos NL","year":"1991","journal-title":"Vasa Suppl"},{"key":"bibr3-1708538115605430","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa0909499"},{"key":"bibr4-1708538115605430","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa0909305"},{"key":"bibr5-1708538115605430","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvs.2010.09.009"},{"key":"bibr6-1708538115605430","doi-asserted-by":"publisher","DOI":"10.1177\/152660289900600105"},{"key":"bibr7-1708538115605430","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvs.2006.01.010"},{"key":"bibr8-1708538115605430","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvs.2007.03.017"},{"key":"bibr9-1708538115605430","doi-asserted-by":"crossref","unstructured":"Bockler D, Holden A, Thompson M, et\u00a0al. Multicenter Nellix EndoVascular Aneurysm Sealing system experience in aneurysm sac sealing.\n                      J Vasc Surg\n                      2015; 62: 290\u2013298.","DOI":"10.1016\/j.jvs.2015.03.031"},{"key":"bibr10-1708538115605430","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejvs.2011.03.007"},{"key":"bibr11-1708538115605430","unstructured":"Endologix,\n                      Nellix EndoVascular Aneurysm Sealing System Instrucions for use\n                      . 2013."},{"key":"bibr12-1708538115605430","doi-asserted-by":"publisher","DOI":"10.1067\/mva.2002.123763"},{"key":"bibr13-1708538115605430","doi-asserted-by":"publisher","DOI":"10.1053\/j.semvascsurg.2008.12.003"},{"key":"bibr14-1708538115605430","doi-asserted-by":"crossref","unstructured":"Rouer M, El Batti S, Julia P, et al. Chimney stent graft for endovascular sealing of a pararenal aortic aneurysm.\n                      Ann Vasc Surg\n                      2014; 28: 1936 e15\u2013e18.","DOI":"10.1016\/j.avsg.2014.07.016"},{"key":"bibr15-1708538115605430","first-page":"286","volume":"48","author":"Kisis K","year":"2012","journal-title":"Medicina (Kaunas)"},{"key":"bibr16-1708538115605430","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejvs.2013.06.017"},{"key":"bibr17-1708538115605430","doi-asserted-by":"publisher","DOI":"10.1583\/14-4698R.1"},{"key":"bibr18-1708538115605430","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejvs.2013.07.008"},{"key":"bibr19-1708538115605430","doi-asserted-by":"publisher","DOI":"10.1583\/13-4320MR.1"},{"key":"bibr20-1708538115605430","doi-asserted-by":"publisher","DOI":"10.1067\/mva.2001.120037"},{"key":"bibr21-1708538115605430","doi-asserted-by":"publisher","DOI":"10.1016\/S0741-5214(03)00738-9"},{"key":"bibr22-1708538115605430","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1016\/j.recesp.2010.10.010","volume":"64","author":"Lopez-Jimenez F","year":"2011","journal-title":"Rev Esp Cardiol"},{"key":"bibr23-1708538115605430","doi-asserted-by":"crossref","unstructured":"Taudorf M, Jensen LP, Vogt KC, et\u00a0al. Endograft limb occlusion in EVAR: iliac tortuosity quantified by three different indices on the basis of preoperative CTA.\n                      Eur J Vasc Endovasc Surg\n                      2014.","DOI":"10.1016\/j.jvs.2014.09.029"}],"container-title":["Vascular"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/1708538115605430","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/1708538115605430","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/1708538115605430","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,2]],"date-time":"2026-05-02T07:29:22Z","timestamp":1777706962000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/1708538115605430"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,7,10]]},"references-count":23,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2016,8]]}},"alternative-id":["10.1177\/1708538115605430"],"URL":"https:\/\/doi.org\/10.1177\/1708538115605430","relation":{},"ISSN":["1708-5381","1708-539X"],"issn-type":[{"value":"1708-5381","type":"print"},{"value":"1708-539X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,7,10]]}}}