{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T20:48:39Z","timestamp":1790628519414,"version":"4.1.0"},"reference-count":20,"publisher":"SAGE Publications","issue":"3","license":[{"start":{"date-parts":[[2025,9,15]],"date-time":"2025-09-15T00:00:00Z","timestamp":1757894400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Vascular"],"published-print":{"date-parts":[[2026,6]]},"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Simulators are used for improvement of vascular surgical skills. This study compares a cadaveric pressurized circulation model (CPCM) with electronic simulators to perform of endovascular and open procedures.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A cadaveric pressurized simulation model was developed and implemented for Endovascular Aortic Repair and peripheral arterial angioplasties. We utilized a system to infuse the body with an extracorporeal perfusion pump; and participants performed the same endovascular procedures on an electronic simulator. Addtionally, simulation for an open aortic repair was also conducted and evaluated. Data were analyzed with the statistical package SPSS version 22.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      We found significant differences in median comparison between simulators; 100% agree CPCM is very similar to an actual patient, median 5 IQR (4\u20135) (\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      = 0.001), it enhances the acquisition of endovascular skills (\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      = 0.001), offers benefits over other simulators (\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      = 0.001), and simulated conditions of a real procedure (\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      = 0.01), likewise can replace animal models (\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      = 0.001). All participants agree or strongly agree it could help improve the success rate and minimize complications in real patients (\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      = 0.01).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The cadaveric model provides superior experience fidelity for endovascular training over an electronic simulator.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/17085381251379298","type":"journal-article","created":{"date-parts":[[2025,9,15]],"date-time":"2025-09-15T18:25:54Z","timestamp":1757960754000},"page":"604-611","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":1,"title":["Comparison of a cadaveric pressurized circulation model and an electronic simulator for vascular and endovascular surgery training"],"prefix":"10.1177","volume":"34","author":[{"given":"Hugo","family":"Laparra-Escare\u00f1o","sequence":"first","affiliation":[{"name":"Instituto Nacional de Ciencias M\u00e9dicas y Nutrici\u00f3n Salvador Zubir\u00e1n"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alejandro","family":"Cancino-Escobar","sequence":"additional","affiliation":[{"name":"Instituto Nacional de Ciencias M\u00e9dicas y Nutrici\u00f3n Salvador Zubir\u00e1n"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carlos A","family":"Vergara-Ascencio","sequence":"additional","affiliation":[{"name":"Instituto Nacional de Ciencias M\u00e9dicas y Nutrici\u00f3n Salvador Zubir\u00e1n"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jose R.","family":"Garc\u00eda-Alva","sequence":"additional","affiliation":[{"name":"Instituto Nacional de Cardiolog\u00eda Ignacio Ch\u00e1vez"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alberto M","family":"Angeles-Castellanos","sequence":"additional","affiliation":[{"name":"Universidad Nacional Aut\u00f3noma de M\u00e9xico"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ruben","family":"Arg\u00fcero-S\u00e1nchez","sequence":"additional","affiliation":[{"name":"Universidad Nacional Aut\u00f3noma de M\u00e9xico"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eduardo E","family":"Montalvo-Jav\u00e9","sequence":"additional","affiliation":[{"name":"Universidad Nacional Aut\u00f3noma de M\u00e9xico"},{"name":"Hospital General de M\u00e9xico"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Omar","family":"S\u00e1nches-Ram\u00edrez","sequence":"additional","affiliation":[{"name":"Universidad Nacional Aut\u00f3noma de M\u00e9xico"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Benjamin","family":"Le\u00f3n-Mancilla","sequence":"additional","affiliation":[{"name":"Universidad Nacional Aut\u00f3noma de M\u00e9xico"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carolina","family":"Ba\u00f1os-Galeana","sequence":"additional","affiliation":[{"name":"Universidad Nacional Aut\u00f3noma de M\u00e9xico"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jos\u00e9 J","family":"Garc\u00eda-Loyola Bioeng","sequence":"additional","affiliation":[{"name":"Universidad Nacional Aut\u00f3noma de M\u00e9xico"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Javier E","family":"Anaya-Ayala","sequence":"additional","affiliation":[{"name":"Instituto Nacional de Ciencias M\u00e9dicas y Nutrici\u00f3n Salvador Zubir\u00e1n"},{"name":"Harvard Medical School"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9664-8703","authenticated-orcid":false,"given":"Carlos A","family":"Hinojosa","sequence":"additional","affiliation":[{"name":"Instituto Nacional de Ciencias M\u00e9dicas y Nutrici\u00f3n Salvador Zubir\u00e1n"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2025,9,15]]},"reference":[{"key":"e_1_3_3_2_2","doi-asserted-by":"publisher","DOI":"10.5115\/acb.2015.48.3.153"},{"key":"e_1_3_3_3_2","doi-asserted-by":"publisher","DOI":"10.1258\/smj.2011.011098"},{"key":"e_1_3_3_4_2","doi-asserted-by":"publisher","DOI":"10.1007\/s40037-015-0250-4"},{"key":"e_1_3_3_5_2","doi-asserted-by":"publisher","DOI":"10.3389\/fpubh.2022.619769"},{"key":"e_1_3_3_6_2","doi-asserted-by":"publisher","DOI":"10.1007\/s12565-022-00689-0"},{"key":"e_1_3_3_7_2","doi-asserted-by":"publisher","DOI":"10.1002\/bjs.11325"},{"key":"e_1_3_3_8_2","doi-asserted-by":"publisher","DOI":"10.1093\/ons\/opx262"},{"issue":"6","key":"e_1_3_3_9_2","first-page":"1484","article-title":"Novel simulation for training trauma surgeons","volume":"71","author":"Aboud ET","year":"2011","unstructured":"Aboud ET, Krisht AF, O\u2019Keeffe T, et al. Novel simulation for training trauma surgeons. J Trauma 2011; 71(6): 1484\u20131490.","journal-title":"J Trauma"},{"key":"e_1_3_3_10_2","doi-asserted-by":"publisher","DOI":"10.1053\/j.tvir.2018.10.003"},{"key":"e_1_3_3_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjsurg.2014.10.027"},{"key":"e_1_3_3_12_2","doi-asserted-by":"publisher","DOI":"10.1093\/milmed\/usy383"},{"key":"e_1_3_3_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjsurg.2005.05.014"},{"key":"e_1_3_3_14_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00276-018-1997-1"},{"key":"e_1_3_3_15_2","doi-asserted-by":"publisher","DOI":"10.1067\/mva.2001.114214"},{"key":"e_1_3_3_16_2","doi-asserted-by":"publisher","DOI":"10.9738\/INTSURG-D-14-00004.1"},{"key":"e_1_3_3_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jviscsurg.2016.06.006"},{"key":"e_1_3_3_18_2","doi-asserted-by":"publisher","DOI":"10.1503\/cjs.023020"},{"key":"e_1_3_3_19_2","doi-asserted-by":"publisher","DOI":"10.1002\/lary.26181"},{"key":"e_1_3_3_20_2","doi-asserted-by":"publisher","DOI":"10.1055\/s-0034-1372470"},{"key":"e_1_3_3_21_2","unstructured":"Morgan TL De Lorenzo RA Ward JA et al. Development of a perfused cadaver model of exsanguinating hemorrhage for procedural training and device evaluation. Internet J Med Simulat Technol 2014; 5(1). https:\/\/ispub.com\/IJMS\/5\/1\/22234#. Consulted on January 29 2025"}],"container-title":["Vascular"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/17085381251379298","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/17085381251379298","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/17085381251379298","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,23]],"date-time":"2026-05-23T05:08:24Z","timestamp":1779512904000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/17085381251379298"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9,15]]},"references-count":20,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2026,6]]}},"alternative-id":["10.1177\/17085381251379298"],"URL":"https:\/\/doi.org\/10.1177\/17085381251379298","relation":{},"ISSN":["1708-5381","1708-539X"],"issn-type":[{"value":"1708-5381","type":"print"},{"value":"1708-539X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,9,15]]}}}