{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,12]],"date-time":"2026-11-12T00:59:36Z","timestamp":1794445176751,"version":"4.9.1"},"reference-count":78,"publisher":"SAGE Publications","issue":"2","license":[{"start":{"date-parts":[[2026,1,29]],"date-time":"2026-01-29T00:00:00Z","timestamp":1769644800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Journal of the Intensive Care Society"],"published-print":{"date-parts":[[2026,5]]},"abstract":"<jats:p>\n                    Each year, around 30,000 intercostal chest drains (ICDs) are inserted in the UK, with complications like displacement being a common concern. Various fixation techniques have been proposed to secure ICDs, but there is no consensus on a gold standard. A scoping review was conducted to identify publications describing ICD fixation methods and frequency with which they become dislodged. Three databases were reviewed: MEDLINE from 1946 to 17th October 2024 through the Ovid\n                    <jats:sup>\u00ae<\/jats:sup>\n                    website portal, PubMed\n                    <jats:sup>\u00ae<\/jats:sup>\n                    , and the Cochrane Central Register of Controlled Trials (CENTRAL). Appropriate search terms and synonyms were applied with Boolean operators and from 5275 identified records 63 were included for review. Nine ICD fixation principles were identified to classify fixation methods: kinking; Poisson-effect (\u201cRoman Sandal\u201d); suture \u201cthrough\u201d the tube; tube fixation points (cuffs or wings); friction\/adhesion (from ties or dressings); external coiling\/locking\/flattening; internal balloons; internal coiling (pigtails); subcutaneous tunnelling. Many fixation methods combined more than one principle. Although no definitive conclusions on the best fixation method can be drawn from this review, trends suggest that incorporating sutures or using combined techniques, such as sutures paired with dressings, cable ties or balloon catheters, may enhance ICD security. In laboratory conditions, the highest pull force was associated with the modified Jo\u2019berg knot. Further robust studies are needed to compare the effectiveness of different fixation methods superior in terms of displacement rate, but also taking into account pain, skin integrity, wound leakage\/infection, or ease of use.\n                  <\/jats:p>","DOI":"10.1177\/17511437251412171","type":"journal-article","created":{"date-parts":[[2026,1,29]],"date-time":"2026-01-29T11:35:27Z","timestamp":1769686527000},"page":"198-212","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":3,"title":["What is the best way to secure a chest drain? A scoping review"],"prefix":"10.1177","volume":"27","author":[{"given":"Chit","family":"Wong","sequence":"first","affiliation":[{"name":"Nottingham University Hospitals NHS Trust, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joshua","family":"Wright","sequence":"additional","affiliation":[{"name":"Nottingham Trent University, England, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francesco","family":"Luke Siena","sequence":"additional","affiliation":[{"name":"Nottingham Trent University, England, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Philip","family":"Breedon","sequence":"additional","affiliation":[{"name":"Nottingham Trent University, England, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David W.","family":"Hewson","sequence":"additional","affiliation":[{"name":"Nottingham University Hospitals NHS Trust, UK"},{"name":"University of Nottingham, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7938-3096","authenticated-orcid":false,"given":"Martin","family":"Beed","sequence":"additional","affiliation":[{"name":"Nottingham University Hospitals NHS Trust, UK"},{"name":"University of Nottingham, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2026,1,29]]},"reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.chest.2021.11.031"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1183\/13993003.01753-2021"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1159\/000489230"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1136\/thoraxjnl-2013-204812"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1001\/jama.2015.16840"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1007\/s40258-019-00461-y"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1136\/thorax-2022-219371"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1177\/1478271520093902004"},{"key":"e_1_3_2_10_2","volume-title":"Rapid response report: risks of chest drain insertion","author":"National Patient Safety Agency","year":"2008","unstructured":"National Patient Safety Agency. Rapid response report: risks of chest drain insertion. NPSA, RRR003, 2008."},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1136\/thorax.58.suppl_2.ii53"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1001\/jamasurg.2021.7050"},{"key":"e_1_3_2_13_2","volume-title":"Advanced trauma life support student course manua","author":"ACS","year":"2018","unstructured":"ACS. Advanced trauma life support student course manual 10th Ed. American College of Surgeons, 2018.","edition":"10"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.7326\/M18-0850"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1097\/00152193-199626070-00014"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1177\/1553350620942369"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1097\/00005373-199401000-00018"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1111\/aas.12238"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00595-007-3697-z"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1136\/emj.16.3.239"},{"key":"e_1_3_2_21_2","first-page":"18","article-title":"Surgical drainage devices. Improved securement = improved outcomes","volume":"18","author":"Carignan M","year":"2000","unstructured":"Carignan M, Nelson L. Surgical drainage devices. Improved securement = improved outcomes. Can Oper Room Nurs J 2000; 18: 18\u201319.","journal-title":"Can Oper Room Nurs J"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0196-0644(83)80129-2"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003246-198606000-00012"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1007\/s11748-012-0184-2"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0003-4975(99)01096-6"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1177\/000992289103000204"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00595-007-3602-9"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.21037\/jtd.2017.09.111"},{"key":"e_1_3_2_29_2","doi-asserted-by":"publisher","DOI":"10.1136\/thoraxjnl-2011-201054c.29"},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003246-198902000-00014"},{"key":"e_1_3_2_31_2","doi-asserted-by":"publisher","DOI":"10.1308\/rcsann.2014.96.1.82"},{"key":"e_1_3_2_32_2","doi-asserted-by":"publisher","DOI":"10.1017\/S1049023X00004994"},{"key":"e_1_3_2_33_2","first-page":"388","article-title":"Securing intercostal drains in trauma surgical practice \u2013 how I do it","volume":"22","author":"Plani F","year":"2004","unstructured":"Plani F. Securing intercostal drains in trauma surgical practice \u2013 how I do it. CME 2004; 22: 388\u2013390.","journal-title":"CME"},{"key":"e_1_3_2_34_2","first-page":"1","article-title":"Subcutaneously anchored sutureless device for securement of chest tubes in neonates with pleural effusion: three case reports","author":"Rodriguez Perez C","year":"2020","unstructured":"Rodriguez Perez C, Romitti MG, Pezzotti E, et al. Subcutaneously anchored sutureless device for securement of chest tubes in neonates with pleural effusion: three case reports. Case Rep Pediatr 2020; 1\u20135.","journal-title":"Case Rep Pediatr"},{"key":"e_1_3_2_35_2","doi-asserted-by":"publisher","DOI":"10.1183\/09031936.98.12040958"},{"key":"e_1_3_2_36_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-5223(19)32482-1"},{"key":"e_1_3_2_37_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0196-0644(82)80205-9"},{"key":"e_1_3_2_38_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2014.07.062"},{"key":"e_1_3_2_39_2","doi-asserted-by":"publisher","DOI":"10.1308\/rcsann.2010.92.8.713"},{"key":"e_1_3_2_40_2","doi-asserted-by":"publisher","DOI":"10.1007\/s11748-021-01699-x"},{"key":"e_1_3_2_41_2","doi-asserted-by":"publisher","DOI":"10.1002\/bjs.1800630214"},{"key":"e_1_3_2_42_2","doi-asserted-by":"publisher","DOI":"10.1097\/00152192-200507000-00013"},{"key":"e_1_3_2_43_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.annemergmed.2018.02.019"},{"key":"e_1_3_2_44_2","doi-asserted-by":"publisher","DOI":"10.1177\/1553350616637692"},{"key":"e_1_3_2_45_2","doi-asserted-by":"publisher","DOI":"10.1136\/jramc-2016-000744"},{"key":"e_1_3_2_46_2","doi-asserted-by":"publisher","DOI":"10.1136\/emermed-2022-213065"},{"key":"e_1_3_2_47_2","doi-asserted-by":"publisher","DOI":"10.1080\/13645706.2019.1671456"},{"key":"e_1_3_2_48_2","doi-asserted-by":"publisher","DOI":"10.1308\/rcsann.2018.0177"},{"key":"e_1_3_2_49_2","doi-asserted-by":"publisher","DOI":"10.21037\/jtd.2019.12.132"},{"key":"e_1_3_2_50_2","doi-asserted-by":"publisher","DOI":"10.1136\/jrnms-101-42"},{"key":"e_1_3_2_51_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.tjem.2018.01.006"},{"key":"e_1_3_2_52_2","doi-asserted-by":"publisher","DOI":"10.1136\/bmjmilitary-2020-001555"},{"key":"e_1_3_2_53_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.2008.00368.x"},{"key":"e_1_3_2_54_2","doi-asserted-by":"publisher","DOI":"10.3906\/sag-1405-75"},{"key":"e_1_3_2_55_2","doi-asserted-by":"publisher","DOI":"10.3389\/fsurg.2022.874983"},{"key":"e_1_3_2_56_2","doi-asserted-by":"publisher","DOI":"10.3390\/medicina59061089"},{"key":"e_1_3_2_57_2","doi-asserted-by":"publisher","DOI":"10.1111\/1759-7714.13157"},{"key":"e_1_3_2_58_2","first-page":"229","article-title":"Comparison of three practices for dressing chest tube insertion sites: a randomized controlled trial","volume":"25","author":"Gross SL","year":"2016","unstructured":"Gross SL, Jennings CD, Clark RC. Comparison of three practices for dressing chest tube insertion sites: a randomized controlled trial. MedSurg Nursing 2016; 25: 229\u2013233.","journal-title":"MedSurg Nursing"},{"key":"e_1_3_2_59_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.ccm.0000439546.64373.ca"},{"key":"e_1_3_2_60_2","doi-asserted-by":"publisher","DOI":"10.21037\/jtd.2017.03.163"},{"key":"e_1_3_2_61_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijsu.2018.06.028"},{"key":"e_1_3_2_62_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.cllc.2021.07.010"},{"key":"e_1_3_2_63_2","doi-asserted-by":"publisher","DOI":"10.14740\/jcs300e"},{"key":"e_1_3_2_64_2","doi-asserted-by":"publisher","DOI":"10.1590\/0100-6991e-20213139"},{"key":"e_1_3_2_65_2","doi-asserted-by":"publisher","DOI":"10.1177\/00031348231157419"},{"key":"e_1_3_2_66_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00431-019-03478-6"},{"key":"e_1_3_2_67_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.surg.2013.04.032"},{"key":"e_1_3_2_68_2","doi-asserted-by":"publisher","DOI":"10.1136\/adc.87.4.331"},{"key":"e_1_3_2_69_2","doi-asserted-by":"publisher","DOI":"10.5152\/TurkThoracJ.2021.20281"},{"key":"e_1_3_2_70_2","doi-asserted-by":"publisher","DOI":"10.1378\/chest.114.4.1116"},{"key":"e_1_3_2_71_2","doi-asserted-by":"publisher","DOI":"10.1136\/thoraxjnl-2016-209333.158"},{"key":"e_1_3_2_72_2","doi-asserted-by":"publisher","DOI":"10.1186\/s12893-023-01952-5"},{"key":"e_1_3_2_73_2","doi-asserted-by":"publisher","DOI":"10.3126\/kumj.v20i1.49829"},{"key":"e_1_3_2_74_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.pedneo.2014.01.002"},{"key":"e_1_3_2_75_2","doi-asserted-by":"publisher","DOI":"10.4037\/ajcc2019645"},{"key":"e_1_3_2_76_2","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-023-37850-2"},{"key":"e_1_3_2_77_2","doi-asserted-by":"publisher","DOI":"10.1080\/10803548.2004.11076594"},{"key":"e_1_3_2_78_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2011.05.009"},{"key":"e_1_3_2_79_2","unstructured":"Medicines & Healthcare Products Regulatory Agency. Off-label use of a medical device. https:\/\/www.gov.uk\/government\/publications\/medical-devices-off-label-use\/off-label-use-of-a-medical-device (accessed 24 February 2025)"}],"container-title":["Journal of the Intensive Care Society"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/17511437251412171","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/17511437251412171","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/17511437251412171","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,16]],"date-time":"2026-05-16T13:47:35Z","timestamp":1778939255000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/17511437251412171"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,29]]},"references-count":78,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2026,5]]}},"alternative-id":["10.1177\/17511437251412171"],"URL":"https:\/\/doi.org\/10.1177\/17511437251412171","relation":{},"ISSN":["1751-1437","1751-1437"],"issn-type":[{"value":"1751-1437","type":"print"},{"value":"1751-1437","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1,29]]}}}