{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,4]],"date-time":"2026-05-04T00:00:39Z","timestamp":1777852839380,"version":"3.51.4"},"reference-count":23,"publisher":"SAGE Publications","issue":"1","license":[{"start":{"date-parts":[[2009,1,7]],"date-time":"2009-01-07T00:00:00Z","timestamp":1231286400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Hand Surg Eur Vol"],"published-print":{"date-parts":[[2009,2]]},"abstract":"<jats:p>Sixty-nine patients with signs of carpal tunnel syndrome (CTS) underwent nerve conduction studies (NCS) and testing with the Pressure-Specified Sensory Device (PSSD). A total of 102 tests were performed (28 bilateral). Twenty patients underwent a carpal tunnel release and were retested after 4 to 6 months. The Symptom Severity Score (SSS) was calculated before and after surgery. A control group of 20 hands in 10 asymptomatic volunteers underwent identical testing. The NCS sensitivity was 87% with a specificity of 90% whereas the PSSD sensitivity was 81% with a specificity of 65%. The combined sensitivity of the two tests was 93%. In the operative group the SSS improved from a mean of 3.34 pre-operatively to 1.95 postoperatively. The NCS improved in 19\/21 hands whereas the PSSD improved in 16\/19 hands. The non-invasive SSS and PSSD can increase the diagnostic yield in CTS, especially when the NCS are normal.<\/jats:p>","DOI":"10.1177\/1753193408094921","type":"journal-article","created":{"date-parts":[[2009,1,7]],"date-time":"2009-01-07T21:06:31Z","timestamp":1231362391000},"page":"60-65","source":"Crossref","is-referenced-by-count":9,"title":["Use of Nerve Conduction Studies and the Pressure-Specified Sensory Device in the Diagnosis of Carpal Tunnel Syndrome"],"prefix":"10.1177","volume":"34","author":[{"given":"D. J.","family":"SLUTSKY","sequence":"first","affiliation":[{"name":"From the South Bay Hand Surgery Center, Torrance, CA, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2009,1,7]]},"reference":[{"key":"b1-0340060","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhsa.2007.04.007"},{"key":"b2-0340060","doi-asserted-by":"publisher","DOI":"10.1055\/s-2007-1000202"},{"key":"b3-0340060","doi-asserted-by":"publisher","DOI":"10.1016\/S0363-5023(98)80056-7"},{"key":"b4-0340060","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhsa.2006.08.017"},{"key":"b5-0340060","doi-asserted-by":"publisher","DOI":"10.1097\/00000637-200045020-00005"},{"key":"b6-0340060","doi-asserted-by":"publisher","DOI":"10.1016\/S0363-5023(89)80091-7"},{"key":"b7-0340060","first-page":"206","volume":"13","author":"Guyette TM","year":"2004","journal-title":"J Surg Orthop Adv"},{"key":"b8-0340060","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-199311000-00002"},{"key":"b9-0340060","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhsa.2007.03.009"},{"key":"b10-0340060","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1097-4598(199909)22:9<1196::AID-MUS5>3.0.CO;2-K"},{"key":"b11-0340060","doi-asserted-by":"publisher","DOI":"10.1034\/j.1600-0404.2002.01368.x"},{"key":"b12-0340060","first-page":"393","volume":"43","author":"Naidu SH","year":"2003","journal-title":"Electromyogr Clin Neurophysiol"},{"key":"b13-0340060","doi-asserted-by":"publisher","DOI":"10.1016\/S0363-5023(09)91050-4"},{"key":"b14-0340060","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhsa.2006.01.012"},{"key":"b15-0340060","doi-asserted-by":"publisher","DOI":"10.1016\/S0266-7681(97)80355-5"},{"key":"b16-0340060","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0404.1997.tb00271.x"},{"key":"b17-0340060","doi-asserted-by":"publisher","DOI":"10.1007\/s100720050047"},{"key":"b18-0340060","doi-asserted-by":"publisher","DOI":"10.1002\/mus.880151106"},{"key":"b19-0340060","doi-asserted-by":"publisher","DOI":"10.2105\/AJPH.88.10.1447"},{"key":"b20-0340060","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1097-4598(199809)21:9<1166::AID-MUS7>3.0.CO;2-5"},{"key":"b21-0340060","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1097-4598(199712)20:12<1477::AID-MUS1>3.0.CO;2-5"},{"key":"b22-0340060","doi-asserted-by":"publisher","DOI":"10.1053\/jhsu.1999.0704"},{"key":"b23-0340060","doi-asserted-by":"publisher","DOI":"10.1097\/00000637-200045030-00005"}],"container-title":["Journal of Hand Surgery (European Volume)"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/1753193408094921","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/1753193408094921","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/1753193408094921","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T22:42:57Z","timestamp":1777502577000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/1753193408094921"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,1,7]]},"references-count":23,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2009,2]]}},"alternative-id":["10.1177\/1753193408094921"],"URL":"https:\/\/doi.org\/10.1177\/1753193408094921","relation":{},"ISSN":["1753-1934","2043-6289"],"issn-type":[{"value":"1753-1934","type":"print"},{"value":"2043-6289","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,1,7]]}}}