{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,29]],"date-time":"2026-07-29T12:38:47Z","timestamp":1785328727884,"version":"3.55.0"},"reference-count":16,"publisher":"SAGE Publications","issue":"4","license":[{"start":{"date-parts":[[2011,5,1]],"date-time":"2011-05-01T00:00:00Z","timestamp":1304208000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["J Hand Surg Eur Vol"],"published-print":{"date-parts":[[2011,5]]},"abstract":"<jats:p>Extensor tendons in the finger are flat and not amenable to repair by core and epitendinous sutures. Mattress sutures and Kessler repairs without epitendinous stitching are often used for extensor tendon divisions in the fingers. Except when in full extension, the finger presents a series of curved surfaces (at each joint) to the tendon. It was hypothesized that extensor tendons are subject to the \u2018tension band\u2019 principle and that they might be amenable to repair by dorsal-only epitendinous sutures. A Silfverski\u00f6ld dorsal-only repair was compared with mattress and Kessler repairs in\u00a0vitro on a curvilinear testing apparatus. The epitendinous technique was found to be significantly more resistant to gapping and rupture, as well as more resistant to deformation (i.e. stiffer) than the conventional techniques.<\/jats:p>","DOI":"10.1177\/1753193410396637","type":"journal-article","created":{"date-parts":[[2011,1,31]],"date-time":"2011-01-31T20:48:58Z","timestamp":1296506938000},"page":"297-302","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":11,"title":["The tension band principle and angular testing of extensor tendon repairs"],"prefix":"10.1177","volume":"36","author":[{"given":"J.","family":"Henderson","sequence":"first","affiliation":[{"name":"Department of Plastic and Reconstructive Surgery, Addenbrooke\u2019s University NHS Trust, Cambridge, UK\u00a0  \u00a0jh@jameshenderson.net"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.","family":"Sutcliffe","sequence":"additional","affiliation":[{"name":"Department of Engineering, University of Cambridge, Cambridge, UK\u00a0"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P.","family":"Gillespie","sequence":"additional","affiliation":[{"name":"Department of Plastic and Reconstructive Surgery, Addenbrooke\u2019s University NHS Trust, Cambridge, UK\u00a0"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2017,1,11]]},"reference":[{"key":"atypb1","doi-asserted-by":"publisher","DOI":"10.1053\/jhsu.2001.26661"},{"key":"atypb2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhsa.2009.04.019"},{"key":"atypb3","doi-asserted-by":"publisher","DOI":"10.1054\/jhsb.2001.0687"},{"key":"atypb4","doi-asserted-by":"publisher","DOI":"10.1053\/jhsu.1999.1061"},{"key":"atypb5","doi-asserted-by":"publisher","DOI":"10.1016\/0266-7681(86)90019-7"},{"key":"atypb6","volume-title":"Biomechanics of the locomotor apparatus. Effects of tension direction on strength of tendon repair","year":"1980"},{"key":"atypb7","doi-asserted-by":"publisher","DOI":"10.1054\/jhsb.1999.0346"},{"key":"atypb8","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhsa.2004.04.025"},{"key":"atypb9","doi-asserted-by":"publisher","DOI":"10.1016\/0266-7681(93)90198-O"},{"key":"atypb10","doi-asserted-by":"publisher","DOI":"10.1054\/jhsb.1999.0230"},{"key":"atypb11","doi-asserted-by":"publisher","DOI":"10.1016\/S0266-7681(97)80353-1"},{"key":"atypb12","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-200105000-00033"},{"key":"atypb13","doi-asserted-by":"publisher","DOI":"10.1053\/jhsu.2003.50028"},{"key":"atypb14","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhsb.2006.03.162"},{"key":"atypb15","doi-asserted-by":"publisher","DOI":"10.1097\/01.PRS.0000161463.83102.85"},{"key":"atypb16","doi-asserted-by":"publisher","DOI":"10.1053\/jhsu.2002.34311"}],"container-title":["Journal of Hand Surgery (European Volume)"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/1753193410396637","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/1753193410396637","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T22:44:22Z","timestamp":1777502662000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/1753193410396637"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,5]]},"references-count":16,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2011,5]]}},"alternative-id":["10.1177\/1753193410396637"],"URL":"https:\/\/doi.org\/10.1177\/1753193410396637","relation":{},"ISSN":["1753-1934","2043-6289"],"issn-type":[{"value":"1753-1934","type":"print"},{"value":"2043-6289","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,5]]}}}