{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,4]],"date-time":"2026-05-04T00:07:01Z","timestamp":1777853221821,"version":"3.51.4"},"reference-count":15,"publisher":"SAGE Publications","issue":"3","license":[{"start":{"date-parts":[[2014,1,10]],"date-time":"2014-01-10T00:00:00Z","timestamp":1389312000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["J Hand Surg Eur Vol"],"published-print":{"date-parts":[[2015,3]]},"abstract":"<jats:p>Tendon transfers frequently require coaptation of two mismatched tendons. In this cadaver study, ultimate load, stiffness, and Young\u2019s modulus were measured in tendon-to-tendon attachments with mismatched donor and recipient tendons, using pronator teres (PT) to extensor carpi radialis brevis (ECRB) and flexor carpi ulnaris (FCU) to extensor digitorum communis (EDC). FCU-to-EDC attachments failed at higher loads than PT-to-ECRB attachments, but they had similar modulus and stiffness values. Ultimate tensile strength of the tendon attachments exceeded the maximum predicted contraction force of any of the transferred muscles, with safety factors of four-fold for the FCU-to-EDC and two-fold for the PT-to-ECRB transfers. This implies that size and shape mismatches should not be contraindications to tendon attachment in transfers. The strength safety factors suggest that postoperative immobilization of these transfers is unnecessary.<\/jats:p>","DOI":"10.1177\/1753193413517327","type":"journal-article","created":{"date-parts":[[2014,1,11]],"date-time":"2014-01-11T20:09:30Z","timestamp":1389470970000},"page":"239-245","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":31,"title":["The mechanical strength of side-to-side tendon repair with mismatched tendon size and shape"],"prefix":"10.1177","volume":"40","author":[{"given":"J.","family":"Frid\u00e9n","sequence":"first","affiliation":[{"name":"Department of Hand Surgery, Sahlgrenska University Hospital, University of Gothenburg, Gothenburg, Sweden"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"T. F.","family":"Tirrell","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, University of California San Diego, San Diego, CA, USA"},{"name":"Research Service, VA San Diego Healthcare System, San Diego, CA, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S.","family":"Bhola","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, University of California San Diego, San Diego, CA, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"R. L.","family":"Lieber","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, University of California San Diego, San Diego, CA, USA"},{"name":"Department of Bioengineering, University of California San Diego, San Diego, CA, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2014,1,10]]},"reference":[{"key":"bibr1-1753193413517327","doi-asserted-by":"publisher","DOI":"10.1197\/j.jht.2005.01.009"},{"key":"bibr2-1753193413517327","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhsa.2010.01.009"},{"key":"bibr3-1753193413517327","first-page":"125","volume":"6","author":"Butler DL","year":"1978","journal-title":"Exerc Sport Sci Rev"},{"key":"bibr4-1753193413517327","doi-asserted-by":"publisher","DOI":"10.1201\/b14481"},{"key":"bibr5-1753193413517327","doi-asserted-by":"publisher","DOI":"10.1177\/145749690809700411"},{"key":"bibr6-1753193413517327","doi-asserted-by":"publisher","DOI":"10.1007\/s00421-004-1225-z"},{"key":"bibr7-1753193413517327","doi-asserted-by":"publisher","DOI":"10.1177\/1753193412442460"},{"key":"bibr8-1753193413517327","doi-asserted-by":"publisher","DOI":"10.1016\/0363-5023(90)90103-X"},{"key":"bibr9-1753193413517327","doi-asserted-by":"publisher","DOI":"10.1016\/0363-5023(92)90444-T"},{"key":"bibr10-1753193413517327","doi-asserted-by":"publisher","DOI":"10.1152\/japplphysiol.00687.2007"},{"key":"bibr11-1753193413517327","doi-asserted-by":"publisher","DOI":"10.1152\/jappl.1984.57.6.1715"},{"key":"bibr12-1753193413517327","doi-asserted-by":"publisher","DOI":"10.3109\/2000656X.2012.684097"},{"key":"bibr13-1753193413517327","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-197254030-00003"},{"key":"bibr14-1753193413517327","doi-asserted-by":"publisher","DOI":"10.3109\/17453676608993274"},{"key":"bibr15-1753193413517327","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhsa.2012.01.026"}],"container-title":["Journal of Hand Surgery (European Volume)"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/1753193413517327","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/1753193413517327","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/1753193413517327","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T22:49:53Z","timestamp":1777502993000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/1753193413517327"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,1,10]]},"references-count":15,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2015,3]]}},"alternative-id":["10.1177\/1753193413517327"],"URL":"https:\/\/doi.org\/10.1177\/1753193413517327","relation":{},"ISSN":["1753-1934","2043-6289"],"issn-type":[{"value":"1753-1934","type":"print"},{"value":"2043-6289","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,1,10]]}}}