{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,4]],"date-time":"2026-05-04T00:04:46Z","timestamp":1777853086889,"version":"3.51.4"},"reference-count":23,"publisher":"SAGE Publications","issue":"5","license":[{"start":{"date-parts":[[2017,2,9]],"date-time":"2017-02-09T00:00:00Z","timestamp":1486598400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["J Hand Surg Eur Vol"],"published-print":{"date-parts":[[2017,6]]},"abstract":"<jats:p>Treatment with a variable angle locking plate can, in theory, maintain near anatomic reduction of intra-articular distal radius fractures, but it is unknown to what extent reduction is maintained as measured by computed tomography. We assessed changes in radiographic fracture position 1 year post-operatively. We included 73 patients of whom 66 patients (90%) had radiographs available for review at 1 year post-operatively. We found a small (less than 2 mm or 2\u00b0) but statistically significant change in several measures. Accounting for inter-observer variability, this is probably within measurement error. We found no difference in change in fracture position or range of motion, grip strength or patient-reported outcome between the use of one or two distal rows of screws. Our results show that minimal changes in reduction can be expected after volar plate fixation in most patients. We recommend using only one screw row routinely, limiting costs, surgical time and the risk of misplacement of screws.<\/jats:p>\n                  <jats:p>Level of evidence: IV<\/jats:p>","DOI":"10.1177\/1753193417690478","type":"journal-article","created":{"date-parts":[[2017,2,9]],"date-time":"2017-02-09T06:45:10Z","timestamp":1486622710000},"page":"493-500","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":14,"title":["Evaluation of radiographic fracture position 1 year after variable angle locking volar distal radius plating: a prospective multicentre case series"],"prefix":"10.1177","volume":"42","author":[{"given":"T.","family":"Teunis","sequence":"first","affiliation":[{"name":"Orthopaedic Hand and Upper Extremity Service, Massachusetts General Hospital \u2013 Harvard Medical School, MA, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J.","family":"Jupiter","sequence":"additional","affiliation":[{"name":"Orthopaedic Hand and Upper Extremity Service, Massachusetts General Hospital \u2013 Harvard Medical School, MA, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"K. D.","family":"Schaser","sequence":"additional","affiliation":[{"name":"Zentrum f\u00fcr Muskoskeletale Chirurgie, Charit\u00e9-Universit\u00e4tsmedizin Berlin, Berlin, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"G.","family":"Fronh\u00f6fer","sequence":"additional","affiliation":[{"name":"Unfallkrankenhaus Graz, Graz, Austria"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"R.","family":"Babst","sequence":"additional","affiliation":[{"name":"Chirurgie und Traumatologie, Kantonsspital Luzern, Luzern, Switzerland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M.","family":"Langer","sequence":"additional","affiliation":[{"name":"Klinik f\u00fcr Unfall-, Hand- und Wiederherstellungschirurgie, Universit\u00e4tsklinikum M\u00fcnster, M\u00fcnster, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A.","family":"Platz","sequence":"additional","affiliation":[{"name":"Klinik f\u00fcr Allgemein-, Hand- und Unfallchirurgie, Stadtspital Triemli, Zurich, Switzerland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A.","family":"Schierz","sequence":"additional","affiliation":[{"name":"Spital Zollikerberg, Zollikerberg, Switzerland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A.","family":"Joeris","sequence":"additional","affiliation":[{"name":"AO Clinical Investigation and Documentation (AOCID), D\u00fcbendorf, Switzerland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"D.","family":"Rikli","sequence":"additional","affiliation":[{"name":"Traumatologie und Unfallchirurgie, Universit\u00e4tsspital Basel, Basel, Switzerland"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2017,2,9]]},"reference":[{"key":"bibr1-1753193417690478","unstructured":"AO Clinical Investigation and Documentation. 2.4 mm Variable Angle LCP Two-Column Volar Distal Radius (VALCP2010), 2010. https:\/\/clinicaltrials.gov\/ct2\/show\/NCT01103297 (16 October 2016)."},{"key":"bibr2-1753193417690478","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.I.01617"},{"key":"bibr3-1753193417690478","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(86)90837-8"},{"key":"bibr4-1753193417690478","doi-asserted-by":"publisher","DOI":"10.1016\/S0363-5023(97)80071-8"},{"key":"bibr5-1753193417690478","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-002-0393-x"},{"key":"bibr6-1753193417690478","doi-asserted-by":"publisher","DOI":"10.1007\/s00402-013-1766-x"},{"key":"bibr7-1753193417690478","doi-asserted-by":"publisher","DOI":"10.1016\/0168-8510(90)90421-9"},{"key":"bibr8-1753193417690478","doi-asserted-by":"publisher","DOI":"10.1007\/s00402-009-0830-z"},{"key":"bibr9-1753193417690478","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.90B5.19448"},{"key":"bibr10-1753193417690478","author":"Johnson NA","year":"2016","journal-title":"J Hand Surg Eur"},{"key":"bibr11-1753193417690478","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.G.01498"},{"key":"bibr12-1753193417690478","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhsa.2005.02.009"},{"key":"bibr13-1753193417690478","doi-asserted-by":"publisher","DOI":"10.1007\/s10195-014-0292-0"},{"key":"bibr14-1753193417690478","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2009.08.024"},{"key":"bibr15-1753193417690478","doi-asserted-by":"publisher","DOI":"10.1016\/S0363-5023(96)80151-1"},{"key":"bibr16-1753193417690478","doi-asserted-by":"publisher","DOI":"10.1097\/00005131-199811000-00009"},{"key":"bibr17-1753193417690478","doi-asserted-by":"publisher","DOI":"10.1016\/j.hcl.2005.02.008"},{"key":"bibr18-1753193417690478","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhsa.2012.10.040"},{"key":"bibr19-1753193417690478","doi-asserted-by":"publisher","DOI":"10.1177\/1536867X1101100108"},{"key":"bibr20-1753193417690478","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhsa.2010.09.033"},{"key":"bibr21-1753193417690478","unstructured":"Synthes. Variable Angle LCP Two-Column Volar Distal Radius Plate 2.4. For fragment-specific fracture fixation with variable angle locking technology, 2015. http:\/\/synthes.vo.llnwd.net\/o16\/LLNWMB8\/INTMobile\/SynthesInternational\/ProductSupportMaterial\/legacy_Synthes_PDF\/DSEM-TRM-0815\u20130464_LR.pdf (17 October 2015)."},{"key":"bibr22-1753193417690478","doi-asserted-by":"publisher","DOI":"10.1097\/BOT.0000000000000379"},{"key":"bibr23-1753193417690478","doi-asserted-by":"publisher","DOI":"10.3109\/17453674.2013.792035"}],"container-title":["Journal of Hand Surgery (European Volume)"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/1753193417690478","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/1753193417690478","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/1753193417690478","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T22:47:50Z","timestamp":1777502870000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/1753193417690478"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,2,9]]},"references-count":23,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2017,6]]}},"alternative-id":["10.1177\/1753193417690478"],"URL":"https:\/\/doi.org\/10.1177\/1753193417690478","relation":{},"ISSN":["1753-1934","2043-6289"],"issn-type":[{"value":"1753-1934","type":"print"},{"value":"2043-6289","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,2,9]]}}}