{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,27]],"date-time":"2026-10-27T10:07:57Z","timestamp":1793095677025,"version":"4.5.0"},"reference-count":30,"publisher":"SAGE Publications","issue":"4","license":[{"start":{"date-parts":[[2025,2,22]],"date-time":"2025-02-22T00:00:00Z","timestamp":1740182400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["J Hand Surg Eur Vol"],"published-print":{"date-parts":[[2025,4]]},"abstract":"<jats:p>\n                    We compared 3-D-printed patient-specific implants (PSIs) with standard palmar locking plates for radiological accuracy after extra-articular corrective osteotomy for malunited distal radial fractures. Eleven patients were operated on with a PSI. Additionally, a plastic printed model of each patient was operated on with a standard plate\n                    <jats:italic>in vitro<\/jats:italic>\n                    . Three months postoperatively, radial alignment in patients and models was compared with the preoperative ideal planning using CT scans. Patients with PSIs showed smaller rotational deviations (median 7\u00b0) compared with standard plate models (9\u00b0). Deviations in the direction of translation, radial inclination, palmar tilt, radial height and ulnar variance were also smaller or similar with the PSI compared with the standard plates. The preoperative grip strength with a median of 8 kg and a Patient-Rated Wrist Evaluation score of 44 improved to 23\u2009kg and 3 points, respectively, at a median follow-up of 13.5 months. Our results indicate superior radial alignment after PSI compared with standard plates, but the clinical relevance of these findings needs to be investigated.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>Level of evidence:<\/jats:bold>\n                    IV\n                  <\/jats:p>","DOI":"10.1177\/17531934241307538","type":"journal-article","created":{"date-parts":[[2025,2,22]],"date-time":"2025-02-22T03:22:33Z","timestamp":1740194553000},"page":"464-471","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":7,"title":["Comparison of patient-specific implants with standard plates after 3-D-planned corrective osteotomy for distal radial malunions"],"prefix":"10.1177","volume":"50","author":[{"given":"Elvira","family":"Bodmer","sequence":"first","affiliation":[{"name":"Clinic for Hand and Plastic Surgery, Cantonal Hospital of Lucerne, Lucerne, Switzerland"},{"name":"Clinic for Orthopaedics and Traumatology, Cantonal Hospital of Zug, Baar, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Urs","family":"Hug","sequence":"additional","affiliation":[{"name":"Clinic for Hand and Plastic Surgery, Cantonal Hospital of Lucerne, Lucerne, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R\u00e9my","family":"Liechti","sequence":"additional","affiliation":[{"name":"Department of Plastic and Hand Surgery, Inselspital, University Hospital of Bern, Bern, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2025,2,22]]},"reference":[{"key":"e_1_3_6_2_1","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.17.00107"},{"key":"e_1_3_6_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hcl.2023.08.015"},{"key":"e_1_3_6_4_1","doi-asserted-by":"publisher","DOI":"10.1186\/1471-2474-12-9"},{"key":"e_1_3_6_5_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11999-012-2767-8"},{"key":"e_1_3_6_6_1","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.17.00544"},{"key":"e_1_3_6_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hcl.2023.09.002"},{"key":"e_1_3_6_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhsa.2017.06.003"},{"key":"e_1_3_6_9_1","doi-asserted-by":"publisher","DOI":"10.1186\/s40001-022-00830-9"},{"key":"e_1_3_6_10_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11751-017-0284-8"},{"key":"e_1_3_6_11_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11517-012-0959-8"},{"key":"e_1_3_6_12_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11548-021-02320-5"},{"key":"e_1_3_6_13_1","first-page":"6","article-title":"Clinical assessment recommendations","author":"Fess EE","year":"1981","unstructured":"Fess EE, Moran C. Clinical assessment recommendations. American Society of Hand Therapists. 1981: 6\u20138.","journal-title":"American Society of Hand Therapists"},{"key":"e_1_3_6_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhsa.2019.05.021"},{"key":"e_1_3_6_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hcl.2012.03.008"},{"key":"e_1_3_6_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhsa.2018.12.013"},{"key":"e_1_3_6_17_1","unstructured":"International Organization for Standardization. ISO 14155:2020. Clinical investigation of medical devices for human subjects \u2013 Good clinical practice. 2020. https:\/\/www.iso.org\/standard\/71690.html (accessed 24 April 2024)"},{"key":"e_1_3_6_18_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00402-017-2765-0"},{"key":"e_1_3_6_19_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00402-018-3046-2"},{"key":"e_1_3_6_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0894-1130(96)80076-7"},{"key":"e_1_3_6_21_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhsa.2023.04.022"},{"key":"e_1_3_6_22_1","doi-asserted-by":"publisher","DOI":"10.1001\/jamanetworkopen.2020.3497"},{"key":"e_1_3_6_23_1","article-title":"Various circular arc radii of the distal volar radius and the implications on volar plate osteosynthesis","volume":"31","author":"Pichler W","year":"2008","unstructured":"Pichler W, Clement H, Hausleitner L, Tanzer K, Tesch NP, Grechenig W. Various circular arc radii of the distal volar radius and the implications on volar plate osteosynthesis. Orthopedics. 2008, 31.","journal-title":"Orthopedics"},{"key":"e_1_3_6_24_1","article-title":"[Malunion of the distal radius: correction with a 3D-printed patient-specific plate]","volume":"164","author":"Raad F","year":"2020","unstructured":"Raad F, Schep NWL. [Malunion of the distal radius: correction with a 3D-printed patient-specific plate]. Ned Tijdschr Geneeskd. 2020, 164.","journal-title":"Ned Tijdschr Geneeskd"},{"key":"e_1_3_6_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhsa.2022.06.021"},{"key":"e_1_3_6_26_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00776-014-0560-0"},{"key":"e_1_3_6_27_1","doi-asserted-by":"publisher","DOI":"10.1177\/1753193416641590"},{"key":"e_1_3_6_28_1","doi-asserted-by":"publisher","DOI":"10.1097\/EDE.0b013e3181577511"},{"key":"e_1_3_6_29_1","doi-asserted-by":"publisher","DOI":"10.3928\/01477447-20130327-22"},{"key":"e_1_3_6_30_1","doi-asserted-by":"publisher","DOI":"10.3928\/01477447-20130122-22"},{"key":"e_1_3_6_31_1","doi-asserted-by":"publisher","DOI":"10.1186\/s13018-021-02312-w"}],"container-title":["Journal of Hand Surgery (European Volume)"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/17531934241307538","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/17531934241307538","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/17531934241307538","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T22:47:01Z","timestamp":1777502821000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/17531934241307538"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,2,22]]},"references-count":30,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2025,4]]}},"alternative-id":["10.1177\/17531934241307538"],"URL":"https:\/\/doi.org\/10.1177\/17531934241307538","relation":{},"ISSN":["1753-1934","2043-6289"],"issn-type":[{"value":"1753-1934","type":"print"},{"value":"2043-6289","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,2,22]]}}}