{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,6]],"date-time":"2026-01-06T02:47:01Z","timestamp":1767667621642,"version":"3.48.0"},"reference-count":10,"publisher":"SAGE Publications","license":[{"start":{"date-parts":[[2025,3,1]],"date-time":"2025-03-01T00:00:00Z","timestamp":1740787200000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"},{"start":{"date-parts":[[2025,3,1]],"date-time":"2025-03-01T00:00:00Z","timestamp":1740787200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Therapeutic Advances in Cardiovascular Disease"],"published-print":{"date-parts":[[2025,3]]},"abstract":"<jats:sec>\n                    <jats:title>Objective:<\/jats:title>\n                    <jats:p>The goal of this study was to compare the computed tomography angiography scans of the segmentation results from the Cvpilot, 3mensio, and Volume Viewer systems to explore the practicability of the Cvpilot system in the automatic segmentation and technical evaluation of the aortic root before transcatheter aortic valve replacement (TAVR).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Design:<\/jats:title>\n                    <jats:p>A total of 154 patients who underwent TAVR at our center from January 2022 to May 2023 were enrolled, and their computed tomography angiography images were analyzed using the Cvpilot, 3mensio, and Volume Viewer systems, respectively.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Setting:<\/jats:title>\n                    <jats:p>Not applicable.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Participants:<\/jats:title>\n                    <jats:p>Not applicable.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Main outcome measures:<\/jats:title>\n                    <jats:p>The reconstructed computed tomography angiography images were evaluated by experts, and the measurements of the aortic roots were analyzed statistically.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Compared with the 3mensio system, 92.2% of patients (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      \u2009=\u2009142) evaluated with the Cvpilot system reached grade A, 5.2% of patients (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      \u2009=\u20098) reached grade B, and 2.6% of patients (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      \u2009=\u20094) reached grade C. Compared with the Volume Viewer system, 90.9% of patients (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      \u2009=\u2009140) evaluated with the Cvpilot system achieved grade A, 7.1% of patients (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      \u2009=\u200911) achieved grade B, and 2.0% of patients (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      \u2009=\u20093) achieved grade C. Furthermore, there was no significant difference among the measurement results of the Cvpilot, 3mensio, and Volume Viewer systems (all\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      \u2009&gt;\u20090.05).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Overall, the Cvpilot system is effective and reliable. It can accurately complete the segmentation and the measurement of aortic root structures, thereby effectively improving the measurement quality before TAVR.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Trial registration:<\/jats:title>\n                    <jats:p>Not applicable.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/17539447251321589","type":"journal-article","created":{"date-parts":[[2025,3,24]],"date-time":"2025-03-24T04:40:26Z","timestamp":1742791226000},"update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":0,"title":["Technical implications of a novel deep learning system in the segmentation and evaluation of computed tomography angiography before transcatheter aortic valve replacement"],"prefix":"10.1177","volume":"19","author":[{"given":"Min","family":"Jin","sequence":"first","affiliation":[{"name":"Department of Cardiothoracic Surgery, Affiliated Drum Tower Hospital, Medical School of Nanjing University, Nanjing, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yu","family":"Mao","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, Xijing Hospital, Xi\u2019an, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2059-1912","authenticated-orcid":false,"given":"Jian","family":"Yang","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, Xijing Hospital, Xi\u2019an, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jian","family":"Liu","sequence":"additional","affiliation":[{"name":"Department of Cardiac Surgery, Guangdong Provincial People\u2019s Hospital, Guangzhou, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Guozhong","family":"Chen","sequence":"additional","affiliation":[{"name":"Department of Medical Imaging, Nanjing First Hospital, Nanjing, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Timoth\u00e9e","family":"Noterdaeme","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Hospital of Liege University, Liege, Belgium"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"R\u00fcdiger","family":"Lange","sequence":"additional","affiliation":[{"name":"Nanjing Saint Medical Technology Co., Ltd., Nanjing, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chenming","family":"Ma","sequence":"additional","affiliation":[{"name":"Nanjing Saint Medical Technology Co., Ltd., Nanjing, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yingqiang","family":"Guo","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, West China Hospital, Chengdu, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0003-1202-5395","authenticated-orcid":false,"given":"Haibo","family":"Zhang","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, Beijing Anzhen Hospital, 37 Anzhen Road, Beijing 100029, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2025,3,24]]},"reference":[{"key":"e_1_3_4_2_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1103510"},{"key":"e_1_3_4_3_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1514616"},{"issue":"18","key":"e_1_3_4_4_2","doi-asserted-by":"crossref","first-page":"1695","DOI":"10.1056\/NEJMoa1814052","article-title":"Transcatheter aortic valve replacement with a balloon-expandable valve in low-risk patients","volume":"380","author":"Mack MJ","year":"2019","unstructured":"Mack MJ, Leon MB, Thourani VH, et al. Transcatheter aortic valve replacement with a balloon-expandable valve in low-risk patients. N Engl J Med 2019; 380(18): 1695\u20131705.","journal-title":"N Engl J Med"},{"issue":"1","key":"e_1_3_4_5_2","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1016\/j.jcct.2016.12.004","article-title":"Automatic 3D aortic annulus sizing by computed tomography in the planning of transcatheter aortic valve implantation","volume":"11","author":"Queiros S","year":"2017","unstructured":"Queiros S, Dubois C, Morais P, et al. Automatic 3D aortic annulus sizing by computed tomography in the planning of transcatheter aortic valve implantation. J Cardiovasc Comput Tomogr 2017; 11(1): 25\u201332.","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"e_1_3_4_6_2","volume-title":"European guidelines on quality criteria for computed tomography","author":"Menzel H","year":"2000","unstructured":"Menzel H, Schibilla H, Teunen D. European guidelines on quality criteria for computed tomography. Luxembourg City: European Commission, 2000."},{"issue":"4","key":"e_1_3_4_7_2","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1016\/j.jfds.2017.05.001","article-title":"An overview on data representation learning: From traditional feature learning to recent deep learning","volume":"2","author":"Zhong G","year":"2016","unstructured":"Zhong G, Wang LN, Ling X, et al. An overview on data representation learning: From traditional feature learning to recent deep learning. J Finance Data Sci 2016; 2(4): 265\u2013278.","journal-title":"J Finance Data Sci"},{"key":"e_1_3_4_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.cmpb.2020.105651"},{"issue":"1","key":"e_1_3_4_9_2","doi-asserted-by":"crossref","first-page":"4829","DOI":"10.1038\/s41467-020-18606-2","article-title":"Rapid vessel segmentation and reconstruction of head and neck angiograms using 3D convolutional neural network","volume":"11","author":"Fu F","year":"2020","unstructured":"Fu F, Wei J, Zhang M, et al. Rapid vessel segmentation and reconstruction of head and neck angiograms using 3D convolutional neural network. Nat Commun 2020; 11(1): 4829.","journal-title":"Nat Commun"},{"key":"e_1_3_4_10_2","doi-asserted-by":"publisher","DOI":"10.1155\/2020\/9843275"},{"key":"e_1_3_4_11_2","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-020-67111-5"}],"container-title":["Therapeutic Advances in Cardiovascular Disease"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/17539447251321589","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/17539447251321589","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/17539447251321589","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,6]],"date-time":"2026-01-06T02:42:05Z","timestamp":1767667325000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/17539447251321589"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3]]},"references-count":10,"alternative-id":["10.1177\/17539447251321589"],"URL":"https:\/\/doi.org\/10.1177\/17539447251321589","relation":{},"ISSN":["1753-9447","1753-9455"],"issn-type":[{"type":"print","value":"1753-9447"},{"type":"electronic","value":"1753-9455"}],"subject":[],"published":{"date-parts":[[2025,3]]},"article-number":"17539447251321589"}}