{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,2]],"date-time":"2026-09-02T10:54:47Z","timestamp":1788346487348,"version":"build-2803163510"},"reference-count":32,"publisher":"SAGE Publications","license":[{"start":{"date-parts":[[2023,1,1]],"date-time":"2023-01-01T00:00:00Z","timestamp":1672531200000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Therapeutic Advances in Urology"],"published-print":{"date-parts":[[2023,1]]},"abstract":"<jats:p> The malleable penile implant is often considered an inferior device to the three-piece inflatable penile prosthesis implant. Nonetheless, the malleable prosthesis has its unique advantages such as lower cost, easier to perform and fewer mechanical complications than inflatable prostheses. Furthermore, its role can be extended to patients with issues relating to poor manual hand dexterity, those undergoing a salvage for infection prosthesis and as an emergency surgical measure in patients presenting with acute ischaemic priapism. Over the past few decades, there have been numerous design and technological advancements to improve overall clinical efficacy, mechanical durability, axial rigidity and device concealability of malleable penile prostheses. The following article provides a narrative review of the six major contemporary malleable penile prosthesis devices in the commercial market, namely, the Coloplast Genesis prosthesis, the Boston Scientific Tactra prosthesis, the Zephyr ZSI 100 and 100 (female-to-male) FTM devices, the Rigi10 prosthesis, the TUBE malleable prosthesis and the Shah prosthesis and evaluates the published outcomes. Appropriate patient selection and strict counselling regarding what to expect with malleable prostheses coupled with adherence to safe surgical principles are paramount to ensure excellent clinical success and patient satisfaction rates. <\/jats:p>","DOI":"10.1177\/17562872231179008","type":"journal-article","created":{"date-parts":[[2023,7,14]],"date-time":"2023-07-14T12:37:15Z","timestamp":1689338235000},"update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":14,"title":["State-of-art review of current malleable penile prosthesis devices in the commercial market"],"prefix":"10.1177","volume":"15","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3373-3668","authenticated-orcid":false,"given":"Eric","family":"Chung","sequence":"first","affiliation":[{"name":"AndroUrology Centre, Suite 3, 530 Boundary Street, Brisbane, QLD 4000, Australia"},{"name":"Department of Urology, Princess Alexandra Hospital, University of Queensland, Brisbane, QLD, Australia"},{"name":"Macquarie University Hospital, Sydney, NSW, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Juan","family":"Wang","sequence":"additional","affiliation":[{"name":"AndroUrology Centre, Brisbane, QLD, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2023,7,14]]},"reference":[{"key":"bibr1-17562872231179008","doi-asserted-by":"publisher","DOI":"10.21037\/tau.2016.12.06"},{"key":"bibr2-17562872231179008","doi-asserted-by":"publisher","DOI":"10.1016\/j.jsxm.2016.01.017"},{"key":"bibr3-17562872231179008","doi-asserted-by":"publisher","DOI":"10.1016\/j.sxmr.2018.04.002"},{"key":"bibr4-17562872231179008","doi-asserted-by":"publisher","DOI":"10.1111\/jsm.13014"},{"key":"bibr5-17562872231179008","doi-asserted-by":"publisher","DOI":"10.1016\/0090-4295(84)90248-6"},{"key":"bibr6-17562872231179008","doi-asserted-by":"publisher","DOI":"10.1016\/0090-4295(86)90147-0"},{"key":"bibr7-17562872231179008","unstructured":"Genesis\u00ae malleable penile prosthesis, https:\/\/products.coloplast.us\/coloplast\/implantable-devices\/mens-health-mh\/erectile-dysfunction\/genesis-malleable-penile-prosthesis\/ (accessed 1 December 2022)."},{"key":"bibr8-17562872231179008","first-page":"2428","volume":"12","author":"Yavuz U","year":"2015","journal-title":"Urol J"},{"key":"bibr9-17562872231179008","doi-asserted-by":"publisher","DOI":"10.1038\/ijir.2016.33"},{"key":"bibr10-17562872231179008","doi-asserted-by":"publisher","DOI":"10.1016\/j.esxm.2021.100486"},{"key":"bibr11-17562872231179008","unstructured":"Tactra\u2122 malleable penile prosthesis, https:\/\/www.bostonscientific.com\/en-US\/products\/penile-prosthesis\/tactra\u2014malleable-penile-prosthesis.html (accessed 1 December 2022)."},{"key":"bibr12-17562872231179008","unstructured":"Rigi10\u2122 malleable penile prosthesis, https:\/\/www.rigicon.com\/malleable-penile-prosthesis\/ (accessed 1 December 2022)."},{"key":"bibr13-17562872231179008","unstructured":"ZSI 100 malleable penile implant, https:\/\/www.zsimplants.ch\/documents\/zsi100\/100_Flyer-2016_V4.pdf (accessed 1 December 2022)."},{"key":"bibr14-17562872231179008","unstructured":"ZSI 100 malleable penile implant, https:\/\/www.zsimplants.ch\/en\/products-en\/erectile-dysfunction\/zsi-100-std-malleable-penile-implant\/zsi-100-std-information\/zsi-100-standard-special-features (accessed 1 December 2022)."},{"key":"bibr15-17562872231179008","unstructured":"ZSI 100 FTM malleable penile implant, https:\/\/www.zsimplants.ch\/en\/products-en\/phalloplasty\/zsi-100-ftm-malleable-penile-implant\/zsi-100-ftm-information (accessed 1 December 2022)."},{"key":"bibr16-17562872231179008","doi-asserted-by":"publisher","DOI":"10.1016\/j.jsxm.2019.09.019"},{"key":"bibr17-17562872231179008","unstructured":"TUBE malleable penile prosthesis, https:\/\/promedon-upf.com\/product\/tube\/ (accessed 1 December 2022)."},{"key":"bibr18-17562872231179008","unstructured":"TUBE malleable penile prosthesis, https:\/\/promedon-upf.com\/wp-content\/uploads\/TUBE_Brochure_ENG-V5.pdf (accessed 1 December 2022)."},{"key":"bibr19-17562872231179008","doi-asserted-by":"publisher","DOI":"10.1159\/000107957"},{"key":"bibr20-17562872231179008","doi-asserted-by":"publisher","DOI":"10.1016\/j.aju.2016.07.002"},{"key":"bibr21-17562872231179008","unstructured":"Surgiwear, http:\/\/www.surgiwear.co.in\/andrology\/implants\/shah-penile-prosthesis.html (accessed 1 December 2022)."},{"key":"bibr22-17562872231179008","unstructured":"http:\/\/www.surgiwear.co.in\/urosurgery\/implants\/shah-penile-prosthesis.html (accessed 1 December 2022)."},{"key":"bibr23-17562872231179008","doi-asserted-by":"publisher","DOI":"10.4103\/iju.IJU_60_21"},{"key":"bibr24-17562872231179008","doi-asserted-by":"publisher","DOI":"10.4103\/0970-1591.38613"},{"key":"bibr25-17562872231179008","doi-asserted-by":"publisher","DOI":"10.1016\/j.esxm.2021.100399"},{"key":"bibr26-17562872231179008","first-page":"26","volume":"45","author":"Patil AY","year":"2018","journal-title":"J Sci Soc"},{"key":"bibr27-17562872231179008","doi-asserted-by":"publisher","DOI":"10.1111\/j.1743-6109.2009.01236.x"},{"key":"bibr28-17562872231179008","doi-asserted-by":"publisher","DOI":"10.1111\/jsm.12803"},{"key":"bibr29-17562872231179008","doi-asserted-by":"publisher","DOI":"10.48083\/GVCC5010"},{"key":"bibr30-17562872231179008","doi-asserted-by":"publisher","DOI":"10.3109\/21681805.2015.1059359"},{"key":"bibr31-17562872231179008","doi-asserted-by":"publisher","DOI":"10.1016\/j.juro.2015.08.091"},{"key":"bibr32-17562872231179008","doi-asserted-by":"publisher","DOI":"10.1016\/j.jsxm.2019.01.318"}],"container-title":["Therapeutic Advances in Urology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/17562872231179008","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/17562872231179008","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/17562872231179008","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,1,25]],"date-time":"2025-01-25T02:21:36Z","timestamp":1737771696000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/17562872231179008"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,1]]},"references-count":32,"alternative-id":["10.1177\/17562872231179008"],"URL":"https:\/\/doi.org\/10.1177\/17562872231179008","relation":{},"ISSN":["1756-2872","1756-2880"],"issn-type":[{"value":"1756-2872","type":"print"},{"value":"1756-2880","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,1]]},"article-number":"17562872231179008"}}