{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,11]],"date-time":"2026-09-11T15:08:41Z","timestamp":1789139321219,"version":"build-2803163510"},"reference-count":27,"publisher":"SAGE Publications","issue":"6","license":[{"start":{"date-parts":[[2026,8,3]],"date-time":"2026-08-03T00:00:00Z","timestamp":1785715200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2026,8,3]],"date-time":"2026-08-03T00:00:00Z","timestamp":1785715200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"funder":[{"DOI":"10.13039\/501100016239","name":"Ministerie van Economische Zaken, Landbouw en Innovatie","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100016239","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Journal of Parkinson\u2019s Disease"],"published-print":{"date-parts":[[2026,9]]},"abstract":"<jats:sec>\n                    <jats:title>Study Objectives<\/jats:title>\n                    <jats:p>The diagnosis of rapid eye movement (REM) sleep behavior disorder (RBD) is of clinical interest, as there is a high rate of future conversion to Parkinson's disease and related neurodegenerative disorders. The clinical standard for diagnosis of RBD relies on human scoring of REM sleep without atonia (RSWA) via polysomnography, which is labor-intensive, costly, and unsuitable for long-term monitoring. Existing (semi-)automatic detection methods often depend on prior manual annotation of REM or suffer from low REM classification performance in this population. We here propose a fully automated system using only a single-channel chin electromyography (EMG) for both REM scoring and RSWA quantification.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>We analyzed 485 polysomnographic recordings, including 30 recordings of subjects with RBD. Using the recently introduced factorized score-based diffusion model, we automatically scored REM epochs based on single-channel chin EMG data, and subsequently quantified RSWA using the REM atonia index from literature.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>The proposed system demonstrated strong performance in REM scoring in both subjects with and without RBD (REM sensitivity \u22650.80, specificity \u22650.97, positive predictive value \u22650.81). The REM atonia index derived from automatic scoring showed strong agreement with manually scored data, with minimal bias (\u22640.03), narrow limits of agreement (\u22640.13), and strong linear correlation (Peason's r\u2009\u2265\u20090.88).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Fully automated RSWA quantification using single-channel chin EMG is feasible and performs comparable to semi-automatic methods that rely on human sleep stage scoring based on polysomnography. This single-sensor approach can improve RBD screening accessibility, particularly in ambulatory settings, and facilitate long term monitoring of RSWA.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Plain language summary title<\/jats:title>\n                    <jats:p>A new way to detect sleep problems linked to Parkinson\u2019s risk using just one chin sensor<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/1877718x261468531","type":"journal-article","created":{"date-parts":[[2026,8,3]],"date-time":"2026-08-03T13:20:26Z","timestamp":1785763226000},"page":"1324-1335","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":0,"title":["Automatic sleep staging and atonia detection in RBD using single-channel chin EMG"],"prefix":"10.1177","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4823-2874","authenticated-orcid":false,"given":"Hans","family":"Van Gorp","sequence":"first","affiliation":[{"name":"Eindhoven University of Technology"},{"name":"Philips Sleep and Respiratory Care, Eindhoven, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jaap F","family":"Van Der Aar","sequence":"additional","affiliation":[{"name":"Eindhoven University of Technology"},{"name":"Philips Sleep and Respiratory Care, Eindhoven, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ruud JG","family":"Van Sloun","sequence":"additional","affiliation":[{"name":"Eindhoven University of Technology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5067-2177","authenticated-orcid":false,"given":"Angelique","family":"Pijpers","sequence":"additional","affiliation":[{"name":"Kempenhaeghe Foundation"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pedro","family":"Fonseca","sequence":"additional","affiliation":[{"name":"Eindhoven University of Technology"},{"name":"Philips Sleep and Respiratory Care, Eindhoven, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sebastiaan","family":"Overeem","sequence":"additional","affiliation":[{"name":"Eindhoven University of Technology"},{"name":"Kempenhaeghe Foundation"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Merel M","family":"Van Gilst","sequence":"additional","affiliation":[{"name":"Eindhoven University of Technology"},{"name":"Kempenhaeghe Foundation"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2026,8,3]]},"reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.smrv.2018.09.008"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1002\/ana.24385"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0089741"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.sleep.2012.10.009"},{"key":"e_1_3_2_6_2","volume-title":"The AASM Manual for the scoring of sleep and associated events: rules, terminology and technical specifications","author":"Troester MM","year":"2023","unstructured":"Troester MM, Quan SF, Berry RB. The AASM Manual for the scoring of sleep and associated events: rules, terminology and technical specifications. Darien, IL: American Academy of Sleep Medicine, 2023."},{"key":"e_1_3_2_7_2","volume-title":"International classification of sleep disorders","author":"American Academy of Sleep Medicine","year":"2023","unstructured":"American Academy of Sleep Medicine. International classification of sleep disorders. Darien, IL: American Academy of Sleep Medicine, 2023."},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1093\/sleep\/zsab257"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.5664\/jcsm.2350"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.sleep.2010.06.003"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1093\/sleep\/30.12.1771"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1097\/WNP.0b013e318162acd7"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1111\/jsr.12304"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1097\/WNP.0000000000000021"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.5665\/sleep.4076"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-022-25163-9"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1038\/s41746-024-01354-8"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinph.2021.01.009"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1109\/JBHI.2025.3565034"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1136\/bmjopen-2019-030996"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.3390\/bioengineering10010109"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.smrv.2023.101745"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1093\/sleep\/zsac150"},{"key":"e_1_3_2_24_2","volume-title":"A manual of standardized terminology, techniques and scoring system for sleep stages of human subjects","author":"Rechtschaffen A","year":"1968","unstructured":"Rechtschaffen A, Kales A. eds. A manual of standardized terminology, techniques and scoring system for sleep stages of human subjects. Washington, DC: Government Printing Office, 1968, (NIH publication no. 204)."},{"key":"e_1_3_2_25_2","first-page":"671","article-title":"Inter-rater reliability for identification of REM sleep in Parkinson\u2019s disease","volume":"23","author":"Bliwise DL","year":"2000","unstructured":"Bliwise DL, Willians ML, Irbe D, et al. Inter-rater reliability for identification of REM sleep in Parkinson\u2019s disease. Sleep 2000; 23: 671\u2013676.","journal-title":"Sleep"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1365-2869.2003.00375.x"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.sleep.2019.12.013"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.1093\/sleep\/zsy133"}],"container-title":["Journal of Parkinson\u2019s Disease"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/1877718X261468531","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/1877718X261468531","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/1877718X261468531","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,11]],"date-time":"2026-09-11T14:13:45Z","timestamp":1789136025000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/1877718X261468531"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,3]]},"references-count":27,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2026,9]]}},"alternative-id":["10.1177\/1877718X261468531"],"URL":"https:\/\/doi.org\/10.1177\/1877718x261468531","relation":{},"ISSN":["1877-7171","1877-718X"],"issn-type":[{"value":"1877-7171","type":"print"},{"value":"1877-718X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,3]]}}}