{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,30]],"date-time":"2026-04-30T13:38:30Z","timestamp":1777556310585,"version":"3.51.4"},"reference-count":13,"publisher":"SAGE Publications","issue":"2","license":[{"start":{"date-parts":[[2011,3,1]],"date-time":"2011-03-01T00:00:00Z","timestamp":1298937600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["J Diabetes Sci Technol"],"published-print":{"date-parts":[[2011,3]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Users of continuous glucose monitoring are concerned with product accuracy and choice of insertion site. The Medtronic NexSensor\u00ae was evaluated for accuracy during 6 days of wear when inserted in the abdomen and buttocks areas.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>Adults (ages 18\u201375) with type 1 diabetes wore two sensors simultaneously for 6 days, one each inserted in the abdomen and buttocks. Subjects underwent a frequent blood sampling study for 12 hours, during which time reference blood glucose values were obtained every 15 minutes and compared to sensor values.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>Sixty-three subjects were enrolled, and 61 subjects completed the study. The mean agreement rate between sensor and blood glucose values was 75.5% [95% confidence interval (CI), 69.5, 81.4] at the abdomen site, 73.8% (95% CI, 68.8, 78.8) at the buttocks site, and 75.6% (95% CI, 70.8, 80.4) when sensor and reference data were combined between sites. Over 90% of paired sensor-reference values on Clarke error grids were within the A and B ranges. The mean absolute relative differences were 17.1% at the abdomen site, 16.5% at the buttocks site, and 16.8% when sites were combined.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>The NexSensor was accurate for inpatient, frequent-sample testing for 6 days when inserted into the abdomen and buttocks. The results of this study also provide evidence that both the abdomen and buttocks are suitable as sensor insertion sites.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/193229681100500224","type":"journal-article","created":{"date-parts":[[2014,1,10]],"date-time":"2014-01-10T10:35:52Z","timestamp":1389350152000},"page":"358-364","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":7,"title":["Accuracy Performance of the Medtronic NexSensor\u00ae for 6 Days in an Inpatient Setting Using Abdomen and Buttocks Insertion Sites"],"prefix":"10.1177","volume":"5","author":[{"given":"Tim","family":"Peoples","sequence":"first","affiliation":[{"name":"Medtronic, Inc., Goleta, California"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Timothy","family":"Bailey","sequence":"additional","affiliation":[{"name":"Advanced Metabolic Care + Research, Inc., Escondido, California"},{"name":"University of California, San Diego School of Medicine, San Diego, California"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ronald","family":"Brazg","sequence":"additional","affiliation":[{"name":"Rainier Clinical Research Center, Inc., Renton, Washington"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Howard C.","family":"Zisser","sequence":"additional","affiliation":[{"name":"Sansum Diabetes Research Institute, Santa Barbara, California"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bob","family":"Janowski","sequence":"additional","affiliation":[{"name":"Medtronic, Inc., Northridge, California"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Suiying","family":"Huang","sequence":"additional","affiliation":[{"name":"Medtronic, Inc., Northridge, California"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cary","family":"Talbot","sequence":"additional","affiliation":[{"name":"Medtronic, Inc., Northridge, California"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qingqing","family":"Yang","sequence":"additional","affiliation":[{"name":"Medtronic, Inc., Northridge, California"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2011,3,1]]},"reference":[{"key":"bibr-bibr1-193229681100500224","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa0805017"},{"key":"bibr-bibr2-193229681100500224","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1002853"},{"key":"bibr-bibr3-193229681100500224","doi-asserted-by":"publisher","DOI":"10.2337\/dc09-0889"},{"key":"bibr-bibr4-193229681100500224","doi-asserted-by":"publisher","DOI":"10.1177\/193229680700100507"},{"key":"bibr-bibr5-193229681100500224","doi-asserted-by":"publisher","DOI":"10.1177\/193229680900300528"},{"key":"bibr-bibr6-193229681100500224","doi-asserted-by":"publisher","DOI":"10.1177\/193229681000400614"},{"key":"bibr-bibr7-193229681100500224","doi-asserted-by":"publisher","DOI":"10.2337\/diacare.10.5.622"},{"key":"bibr-bibr8-193229681100500224","volume-title":"Guardian\u00ae REAL-Time Continuous Glucose Monitoring System User Guide","author":"Medtronic MiniMed, Inc","year":"2006"},{"key":"bibr-bibr9-193229681100500224","doi-asserted-by":"publisher","DOI":"10.1177\/193229680900300519"},{"key":"bibr-bibr10-193229681100500224","doi-asserted-by":"publisher","DOI":"10.1089\/dia.2008.0109"},{"key":"bibr-bibr11-193229681100500224","doi-asserted-by":"publisher","DOI":"10.2337\/dc07-2401"},{"key":"bibr-bibr12-193229681100500224","doi-asserted-by":"publisher","DOI":"10.1111\/j.1464-5491.2009.02924.x"},{"key":"bibr-bibr13-193229681100500224","doi-asserted-by":"publisher","DOI":"10.1089\/152091504773731285"}],"container-title":["Journal of Diabetes Science and Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/193229681100500224","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/193229681100500224","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T18:14:18Z","timestamp":1777400058000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/193229681100500224"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,3]]},"references-count":13,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2011,3]]}},"alternative-id":["10.1177\/193229681100500224"],"URL":"https:\/\/doi.org\/10.1177\/193229681100500224","relation":{},"ISSN":["1932-2968","1932-2968"],"issn-type":[{"value":"1932-2968","type":"print"},{"value":"1932-2968","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,3]]}}}