{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,11]],"date-time":"2026-09-11T08:03:15Z","timestamp":1789113795254,"version":"build-2803163510"},"reference-count":28,"publisher":"SAGE Publications","issue":"1","license":[{"start":{"date-parts":[[2020,8,12]],"date-time":"2020-08-12T00:00:00Z","timestamp":1597190400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"funder":[{"name":"RSP Systems A\/S, Denmark."}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["J Diabetes Sci Technol"],"published-print":{"date-parts":[[2021,1]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Noninvasive glucose monitoring (NIGM) in diabetes is a long-sought-for technology. Among the many attempts Raman spectroscopy was considered as the most promising because of its glucose specificity. In this study, a recently developed prototype (GlucoBeam, RSP Systems A\/S, Denmark) was tested in patients with type 1 diabetes to establish calibration models and to demonstrate proof of concept for this device in real use.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>The NIGM table-top prototype was used by 15 adult subjects with type 1 diabetes for up to 25\u2009days at home and in an in-clinic setting. On each day, the subjects performed at least six measurement units throughout the day. Each measurement unit comprised two capillary blood glucose measurements, two scans with an intermittent scanning continuous glucose monitoring (CGM) system, and two NIGM measurements using the thenar of the subject\u2019s right hand.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>Calibration models were established using data from 19 to 24\u2009days. The remaining 3-8\u2009days were used for independent validation. The mean absolute relative difference of the NIGM prototype was 23.6%\u2009\u00b1\u200913.1% for the outpatient days, 28.2%\u2009\u00b1\u20099.9% for the in-clinic day, and 26.3%\u2009\u00b1\u200910.8% for the complete study. Consensus error grid analysis of the NIGM prototype for the complete study showed 93.6% of values in clinically acceptable zones A and B.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>This proof of concept study demonstrated a practical realization of a Raman-based NIGM device, with performance on par with early-generation CGM systems. The findings will assist in further performance improvements of the device.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/1932296820947112","type":"journal-article","created":{"date-parts":[[2020,8,12]],"date-time":"2020-08-12T08:29:57Z","timestamp":1597220997000},"page":"11-18","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":36,"title":["Proof of Concept for a New Raman-Based Prototype for Noninvasive Glucose Monitoring"],"prefix":"10.1177","volume":"15","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4629-7754","authenticated-orcid":false,"given":"Stefan","family":"Pleus","sequence":"first","affiliation":[{"name":"Institut f\u00fcr Diabetes-Technologie, Forschungs- und Entwicklungsgesellschaft mbH an der Universit\u00e4t Ulm, Ulm, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9873-0989","authenticated-orcid":false,"given":"Sebastian","family":"Schauer","sequence":"additional","affiliation":[{"name":"Institut f\u00fcr Diabetes-Technologie, Forschungs- und Entwicklungsgesellschaft mbH an der Universit\u00e4t Ulm, Ulm, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nina","family":"Jendrike","sequence":"additional","affiliation":[{"name":"Institut f\u00fcr Diabetes-Technologie, Forschungs- und Entwicklungsgesellschaft mbH an der Universit\u00e4t Ulm, Ulm, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eva","family":"Zschornack","sequence":"additional","affiliation":[{"name":"Institut f\u00fcr Diabetes-Technologie, Forschungs- und Entwicklungsgesellschaft mbH an der Universit\u00e4t Ulm, Ulm, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Manuela","family":"Link","sequence":"additional","affiliation":[{"name":"Institut f\u00fcr Diabetes-Technologie, Forschungs- und Entwicklungsgesellschaft mbH an der Universit\u00e4t Ulm, Ulm, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karl Dietrich","family":"Hepp","sequence":"additional","affiliation":[{"name":"Independent Scientific Advisor for RSP Systems A\/S, RSP Systems A\/S, Denmark"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cornelia","family":"Haug","sequence":"additional","affiliation":[{"name":"Institut f\u00fcr Diabetes-Technologie, Forschungs- und Entwicklungsgesellschaft mbH an der Universit\u00e4t Ulm, Ulm, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0406-9529","authenticated-orcid":false,"given":"Guido","family":"Freckmann","sequence":"additional","affiliation":[{"name":"Institut f\u00fcr Diabetes-Technologie, Forschungs- und Entwicklungsgesellschaft mbH an der Universit\u00e4t Ulm, Ulm, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2020,8,12]]},"reference":[{"key":"bibr1-1932296820947112","volume-title":"IDF Diabetes Atlas","author":"International Diabetes Federation","year":"2019","edition":"9"},{"key":"bibr2-1932296820947112","doi-asserted-by":"publisher","DOI":"10.2337\/dc18-Sint01"},{"key":"bibr3-1932296820947112","doi-asserted-by":"publisher","DOI":"10.1136\/bmjdrc-2016-000342"},{"key":"bibr4-1932296820947112","doi-asserted-by":"publisher","DOI":"10.1007\/s00216-018-1395-x"},{"key":"bibr5-1932296820947112","doi-asserted-by":"publisher","DOI":"10.1515\/labmed-2019-0189"},{"key":"bibr6-1932296820947112","doi-asserted-by":"publisher","DOI":"10.1126\/sciadv.aay5206"},{"key":"bibr7-1932296820947112","author":"Ferraro JR","year":"2003","journal-title":"Introductory Raman spectroscopy"},{"key":"bibr8-1932296820947112","doi-asserted-by":"publisher","DOI":"10.1016\/j.medengphy.2007.06.003"},{"key":"bibr9-1932296820947112","doi-asserted-by":"publisher","DOI":"10.1117\/1.1920212"},{"key":"bibr10-1932296820947112","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0197134"},{"key":"bibr11-1932296820947112","doi-asserted-by":"publisher","DOI":"10.1007\/s13300-016-0223-6"},{"key":"bibr12-1932296820947112","doi-asserted-by":"publisher","DOI":"10.1001\/archderm.1988.01670060015008"},{"key":"bibr13-1932296820947112","doi-asserted-by":"publisher","DOI":"10.4155\/bio.13.337"},{"key":"bibr14-1932296820947112","doi-asserted-by":"publisher","DOI":"10.1089\/dia.2017.0416"},{"key":"bibr15-1932296820947112","author":"International Organization for Standardization","year":"2003","journal-title":"EN ISO 17511:2003"},{"key":"bibr16-1932296820947112","doi-asserted-by":"publisher","DOI":"10.1016\/0731-7085(91)80188-F"},{"key":"bibr17-1932296820947112","doi-asserted-by":"publisher","DOI":"10.1016\/0967-0661(95)00014-L"},{"key":"bibr18-1932296820947112","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(86)90837-8"},{"key":"bibr19-1932296820947112","doi-asserted-by":"publisher","DOI":"10.1038\/73213"},{"key":"bibr20-1932296820947112","doi-asserted-by":"publisher","DOI":"10.1126\/sciadv.aba5320"},{"key":"bibr21-1932296820947112","doi-asserted-by":"publisher","DOI":"10.2337\/db19-107-LB"},{"key":"bibr22-1932296820947112","doi-asserted-by":"publisher","DOI":"10.1136\/bmjdrc-2016-000320"},{"key":"bibr23-1932296820947112","doi-asserted-by":"publisher","DOI":"10.1089\/dia.2018.0105"},{"key":"bibr24-1932296820947112","doi-asserted-by":"publisher","DOI":"10.1007\/s00216-011-5004-5"},{"key":"bibr25-1932296820947112","doi-asserted-by":"publisher","DOI":"10.3390\/molecules24081500"},{"key":"bibr26-1932296820947112","doi-asserted-by":"publisher","DOI":"10.1177\/193229680900300519"},{"key":"bibr27-1932296820947112","unstructured":"Food and Drug Administration. Summary of safety and effectiveness data. DexCom\u2122 STS\u2122 continuous glucose monitoring system. https:\/\/www.accessdata.fda.gov\/cdrh_docs\/pdf5\/p050012b.pdf. Accessed February 2020."},{"key":"bibr28-1932296820947112","unstructured":"Food and Drug Administration. Summary of safety and effectiveness data: Medtronic guardian RT. Available at: http:\/\/www.fda.gov\/cdrh\/PDF\/p980022s011b.pdf. Accessed April, 2017."}],"container-title":["Journal of Diabetes Science and Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/1932296820947112","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/1932296820947112","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/1932296820947112","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T18:14:48Z","timestamp":1777400088000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/1932296820947112"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,8,12]]},"references-count":28,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,1]]}},"alternative-id":["10.1177\/1932296820947112"],"URL":"https:\/\/doi.org\/10.1177\/1932296820947112","relation":{},"ISSN":["1932-2968","1932-2968"],"issn-type":[{"value":"1932-2968","type":"print"},{"value":"1932-2968","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,8,12]]}}}