{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,21]],"date-time":"2026-08-21T13:06:50Z","timestamp":1787317610277,"version":"build-2736575974"},"reference-count":41,"publisher":"SAGE Publications","issue":"1","license":[{"start":{"date-parts":[[2022,1,20]],"date-time":"2022-01-20T00:00:00Z","timestamp":1642636800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"funder":[{"DOI":"10.13039\/100000062","name":"National Institute of Diabetes and Digestive and Kidney Diseases","doi-asserted-by":"publisher","award":["R01DK124789"],"award-info":[{"award-number":["R01DK124789"]}],"id":[{"id":"10.13039\/100000062","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["J Diabetes Sci Technol"],"published-print":{"date-parts":[[2023,1]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>A critical factor in healing diabetic foot ulcers is patient adherence to offloading devices. We tested a smart offloading boot (SmartBoot) combined with a smartwatch app and cloud dashboard to remotely monitor patient adherence and activity. In addition, the impact of SmartBoot on balance, gait, and user experience was investigated.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>Fourteen volunteers (31.6\u00b18.7 years; 64% female) performed natural activities (eg, sitting, standing, walking) with and without the SmartBoot for approximately 30 minutes. All participants completed balance tests, 10-meter walking tests at slow, normal, and fast pace while wearing the SmartBoot, and a user experience questionnaire. The accuracy of real-time adherence reporting was assessed by comparing the SmartBoot and staff observation. Center of mass (COM) sway and step counts were measured using a validated wearable system.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>Average sensitivity, specificity, and accuracy for adherence and non-adherence were 90.6%, 88.0%, and 89.3%, respectively. The COM sway area was significantly smaller with the SmartBoot than without the SmartBoot regardless of test condition. Step count error was 4.4% for slow waking, 36.2% for normal walking, 16.0% for fast walking. Most participants agreed that the SmartBoot is easy to use, relatively comfortable, nonintrusive, and innovative.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>To our knowledge, this is the first smart offloading system that enables remote patient monitoring and real-time adherence and activity reporting. The SmartBoot enhanced balance performance, likely due to somatosensory feedback. Questionnaire results highlight SmartBoot\u2019s technical and clinical potential. Future studies warrant clinical validation of real-time non-adherence alerting to improve wound healing outcomes in people with diabetic foot ulcers.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/19322968211070850","type":"journal-article","created":{"date-parts":[[2022,1,20]],"date-time":"2022-01-20T06:27:46Z","timestamp":1642660066000},"page":"42-51","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":35,"title":["Smart Offloading Boot System for Remote Patient Monitoring: Toward Adherence Reinforcement and Proper Physical Activity Prescription for Diabetic Foot Ulcer Patients"],"prefix":"10.1177","volume":"17","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6137-5098","authenticated-orcid":false,"given":"Catherine","family":"Park","sequence":"first","affiliation":[{"name":"Interdisciplinary Consortium on Advanced Motion Performance, Michael E. DeBakey Department of Surgery, Baylor College of Medicine, Houston, TX, USA"},{"name":"VA HSR&amp;D, Center for Innovations in Quality, Effectiveness, and Safety, Michael E. DeBakey VA Medical Center, Houston, TX, USA"},{"name":"Big Data Scientist Training Enhancement Program, VA Office of Research and Development, Washington, DC, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ramkinker","family":"Mishra","sequence":"additional","affiliation":[{"name":"Interdisciplinary Consortium on Advanced Motion Performance, Michael E. DeBakey Department of Surgery, Baylor College of Medicine, Houston, TX, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Davide","family":"Vigano","sequence":"additional","affiliation":[{"name":"Sensoria Health Inc, Redmond, WA, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maurizio","family":"Macagno","sequence":"additional","affiliation":[{"name":"Sensoria Health Inc, Redmond, WA, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefano","family":"Rossotti","sequence":"additional","affiliation":[{"name":"Sensoria Health Inc, Redmond, WA, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karen","family":"D\u2019Huyvetter","sequence":"additional","affiliation":[{"name":"Southwestern Academic Limb Salvage Alliance, Keck School of Medicine, University of Southern California, Los Angeles, CA, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jason","family":"Garcia","sequence":"additional","affiliation":[{"name":"Southwestern Academic Limb Salvage Alliance, Keck School of Medicine, University of Southern California, Los Angeles, CA, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David G.","family":"Armstrong","sequence":"additional","affiliation":[{"name":"Southwestern Academic Limb Salvage Alliance, Keck School of Medicine, University of Southern California, Los Angeles, CA, USA"},{"name":"National Center for Rehabilitation at Rancho Los Amigos, Downey, CA, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bijan","family":"Najafi","sequence":"additional","affiliation":[{"name":"Interdisciplinary Consortium on Advanced Motion Performance, Michael E. DeBakey Department of Surgery, Baylor College of Medicine, Houston, TX, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2022,1,20]]},"reference":[{"key":"e_1_3_3_2_2","volume-title":"Diabetic Foot Ulcer","author":"Oliver TI","year":"2021","unstructured":"Oliver TI, Mutluoglu M. Diabetic Foot Ulcer. Treasure Island, FL: Statpearls; 2021."},{"key":"e_1_3_3_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.dsx.2015.04.007."},{"key":"e_1_3_3_4_2","doi-asserted-by":"publisher","DOI":"10.4103\/0973-3930.62596."},{"key":"e_1_3_3_5_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMra1615439."},{"key":"e_1_3_3_6_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00125-006-0491-1."},{"key":"e_1_3_3_7_2","doi-asserted-by":"publisher","DOI":"10.2337\/diacare.26.5.1435."},{"key":"e_1_3_3_8_2","doi-asserted-by":"publisher","DOI":"10.1093\/cid\/cis346."},{"key":"e_1_3_3_9_2","doi-asserted-by":"publisher","DOI":"10.2337\/diacare.22.3.382."},{"key":"e_1_3_3_10_2","doi-asserted-by":"publisher","DOI":"10.1111\/dme.13054."},{"key":"e_1_3_3_11_2","doi-asserted-by":"publisher","DOI":"10.1097\/00152192-200511000-00007."},{"key":"e_1_3_3_12_2","doi-asserted-by":"publisher","DOI":"10.2337\/dc16-2189."},{"key":"e_1_3_3_13_2","doi-asserted-by":"publisher","DOI":"10.1186\/s13047-020-00383-2."},{"key":"e_1_3_3_14_2","doi-asserted-by":"publisher","DOI":"10.3402\/dfa.v4i0.21847."},{"key":"e_1_3_3_15_2","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0134914."},{"key":"e_1_3_3_16_2","doi-asserted-by":"publisher","DOI":"10.1002\/dmrr.2702."},{"key":"e_1_3_3_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvs.2015.10.006."},{"key":"e_1_3_3_18_2","doi-asserted-by":"publisher","DOI":"10.1002\/dmrr.3275."},{"key":"e_1_3_3_19_2","doi-asserted-by":"publisher","DOI":"10.12968\/jowc.2015.24.12.560."},{"key":"e_1_3_3_20_2","doi-asserted-by":"publisher","DOI":"10.1002\/dmrr.3274."},{"key":"e_1_3_3_21_2","doi-asserted-by":"publisher","DOI":"10.2337\/diacare.26.9.2595."},{"key":"e_1_3_3_22_2","doi-asserted-by":"publisher","DOI":"10.2337\/dc08-0771."},{"key":"e_1_3_3_23_2","doi-asserted-by":"publisher","DOI":"10.1177\/1932296816662959."},{"key":"e_1_3_3_24_2","doi-asserted-by":"publisher","DOI":"10.1177\/1932296819839703."},{"key":"e_1_3_3_25_2","doi-asserted-by":"publisher","DOI":"10.3390\/s18113939."},{"key":"e_1_3_3_26_2","doi-asserted-by":"publisher","DOI":"10.1159\/000494114."},{"key":"e_1_3_3_27_2","first-page":"319","article-title":"Perceived usefulness, perceived ease of use, and user acceptance of information technology","volume":"1989","author":"Davis FD","unstructured":"Davis FD. Perceived usefulness, perceived ease of use, and user acceptance of information technology. MIS Quarterly. 1989:319-340.","journal-title":"MIS Quarterly"},{"key":"e_1_3_3_28_2","doi-asserted-by":"publisher","DOI":"10.4324\/9780203771587"},{"key":"e_1_3_3_29_2","doi-asserted-by":"publisher","DOI":"10.1002\/dmrr.3239."},{"key":"e_1_3_3_30_2","doi-asserted-by":"publisher","DOI":"10.3390\/medicina57040377."},{"key":"e_1_3_3_31_2","doi-asserted-by":"publisher","DOI":"10.1177\/1932296816689105."},{"key":"e_1_3_3_32_2","doi-asserted-by":"publisher","DOI":"10.1152\/jn.1986.55.6.1369."},{"key":"e_1_3_3_33_2","doi-asserted-by":"publisher","DOI":"10.2519\/jospt.1993.17.3.149."},{"key":"e_1_3_3_34_2","doi-asserted-by":"publisher","DOI":"10.1177\/193229681000400411."},{"key":"e_1_3_3_35_2","doi-asserted-by":"publisher","DOI":"10.1177\/193229681300700506."},{"key":"e_1_3_3_36_2","doi-asserted-by":"publisher","DOI":"10.3389\/fphys.2019.00935."},{"key":"e_1_3_3_37_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinbiomech.2014.10.007."},{"key":"e_1_3_3_38_2","doi-asserted-by":"publisher","DOI":"10.1177\/193229681300700507."},{"key":"e_1_3_3_39_2","doi-asserted-by":"publisher","DOI":"10.1111\/jgs.15929."},{"key":"e_1_3_3_40_2","unstructured":"Najafi B Boloori A-R Wrobel J. Intelligent device to monitor and remind patients with footwear walking aids braces or orthotics. Google Patents. USA; 2014."},{"key":"e_1_3_3_41_2","doi-asserted-by":"publisher","DOI":"10.1177\/1932296818768618."},{"key":"e_1_3_3_42_2","doi-asserted-by":"publisher","DOI":"10.1177\/1534734614545874."}],"container-title":["Journal of Diabetes Science and Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/19322968211070850","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/19322968211070850","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/19322968211070850","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T18:15:38Z","timestamp":1777400138000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/19322968211070850"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,1,20]]},"references-count":41,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2023,1]]}},"alternative-id":["10.1177\/19322968211070850"],"URL":"https:\/\/doi.org\/10.1177\/19322968211070850","relation":{},"ISSN":["1932-2968","1932-2968"],"issn-type":[{"value":"1932-2968","type":"print"},{"value":"1932-2968","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,1,20]]}}}