{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T13:13:39Z","timestamp":1788527619645,"version":"build-2803163510"},"reference-count":19,"publisher":"SAGE Publications","license":[{"start":{"date-parts":[[2026,9,2]],"date-time":"2026-09-02T00:00:00Z","timestamp":1788307200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Respiratory Care"],"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>\n                      Portable home ventilators operating in pressure-targeted passive leak mode are widely prescribed for patients with neuromuscular disease (NMD). In this passive ventilation configuration, delivered tidal volume (V\n                      <jats:sub>Ti<\/jats:sub>\n                      ) is determined not by clinician-set parameters alone but by device-specific pressurization algorithms. Inter-device V\n                      <jats:sub>Ti<\/jats:sub>\n                      variability has been demonstrated in cross-sectional bench studies; however, whether firmware updates alter these characteristics longitudinally\u2014and whether such alterations are clinically important\u2014has not been systematically examined. NMD is a progressive condition in which respiratory system compliance deteriorates over time, further amplifying the clinical relevance of device pressurization characteristics.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>\n                      We performed bench testing of portable home ventilators in 3 measurement cohorts: 2018 (no.\u00a0= 7 devices), 2020 (no. = 3 devices), and 2021 (no. = 4 devices). All cohorts used an identical protocol: single-limb passive leak circuit (Intersurgical), 1.8-m corrugated tubing, SmartLung test lung (IMT Analytics, Buchs, Switzerland), inspiratory positive airway pressure (IPAP) 15\u2009cm H\n                      <jats:sub>2<\/jats:sub>\n                      O\/expiratory positive airway pressure 5\u2009cm H\n                      <jats:sub>2<\/jats:sub>\n                      O, T\n                      <jats:sub>I<\/jats:sub>\n                      1.0 s, breathing frequency 10 breaths\/min, rise time fastest, and Body Temperature, Pressure, Saturated (BTPS) correction. Three test conditions simulated NMD mechanics (C30\/R5: compliance 30\u2009mL\/cm H\n                      <jats:sub>2<\/jats:sub>\n                      O, resistance 5\u2009cm H\n                      <jats:sub>2<\/jats:sub>\n                      O\/L\/s), high airway resistance (C30\/R50), and low compliance (C20\/R5). Data were logged continuously for each condition for 60\u2009min at a 10-Hz output interval (CITREX H4 analyzer; IMT Analytics), yielding \u223c590 complete breath cycles per condition. Ensemble-averaged V\n                      <jats:sub>Ti<\/jats:sub>\n                      , pressurization indices at 300 and 500 ms (P\n                      <jats:sub>300<\/jats:sub>\n                      ms, P\n                      <jats:sub>500<\/jats:sub>\n                      ms), and inspiratory flow at 80% of the set T\n                      <jats:sub>I<\/jats:sub>\n                      (F\n                      <jats:sub>80<\/jats:sub>\n                      %T\n                      <jats:sub>I<\/jats:sub>\n                      ) were derived from all breath cycles.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Under C30\/R5 in the 2018 cohort, inter-device V\n                      <jats:sub>Ti<\/jats:sub>\n                      ranged from 308 to 424\u2009mL (range 116\u2009mL; 32.7% of the cohort mean). Devices were classified into 2 flow profile categories: high late-T\n                      <jats:sub>I<\/jats:sub>\n                      flow (VOCSN, F\n                      <jats:sub>80<\/jats:sub>\n                      %T\n                      <jats:sub>I<\/jats:sub>\n                      = 11.3\u2009L\/min; Vivo 60, 9.8\u2009L\/min) and early flow decay (Stellar 100 [VELIA], Trilogy 100, PB560, Astral 150, A40; F\n                      <jats:sub>80<\/jats:sub>\n                      %T\n                      <jats:sub>I<\/jats:sub>\n                      3.0\u20137.2\u2009L\/min). Longitudinal comparison revealed clinically important V\n                      <jats:sub>Ti<\/jats:sub>\n                      reduction following firmware updates: VOCSN decreased from 424 \u00b1 4.8\u2009mL (v4.01.06R, 2018) to 269 \u00b1 4.5\u2009mL (v4.13.00R, 2021), a reduction of 155\u2009mL (\u221237%); Trilogy EVO decreased from 396 \u00b1 2.0\u2009mL (v1.01, 2020) to 275 \u00b1 1.2\u2009mL (v1.04.06, 2021), a reduction of 121\u2009mL (\u221231%); and Vivo 45LS decreased from 515 \u00b1 2.6\u2009mL (early lot, 2020) to 316 \u00b1 3.0\u2009mL (revised firmware, 2021), a reduction of 199\u2009mL (\u221239%). In each case, P\n                      <jats:sub>300<\/jats:sub>\n                      ms was preserved across firmware versions, whereas F\n                      <jats:sub>80<\/jats:sub>\n                      %T\n                      <jats:sub>I<\/jats:sub>\n                      fell sharply (VOCSN: 11.3 to 1.4\u2009L\/min; Trilogy EVO: 8.3 to 2.0\u2009L\/min; Vivo 45LS: 21.5 to \u22120.5\u2009L\/min), consistent with compromised pressure maintenance fidelity during the latter phase of inspiration. Under C20\/R5, V\n                      <jats:sub>Ti<\/jats:sub>\n                      converged to 114\u2013134\u2009mL across all devices and cohorts regardless of firmware version.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>\n                      Inter-device V\n                      <jats:sub>Ti<\/jats:sub>\n                      variability of up to 32.7% under identical settings indicates that device selection directly influences ventilation adequacy in passive NMD ventilation. Firmware updates produced a clinically important 31\u201339% reduction in V\n                      <jats:sub>Ti<\/jats:sub>\n                      without any modification of clinician-set parameters, with altered pressure maintenance fidelity in the latter phase of inspiration demonstrated as the primary mechanism. These changes reflect proprietary algorithm modifications that were implemented, typically not detailed in standard firmware release notes available to clinicians. In patients with low respiratory system compliance, device substitution is unlikely to resolve the V\n                      <jats:sub>Ti<\/jats:sub>\n                      deficit; IPAP adjustment represents a primary strategy within the existing circuit. Clinicians managing ventilator-dependent NMD patients should be aware that the V\n                      <jats:sub>Ti<\/jats:sub>\n                      actually delivered may not correspond to expectations based on set parameters and should verify V\n                      <jats:sub>Ti<\/jats:sub>\n                      delivery after firmware updates. Knowledge of device-specific pressurization characteristics should inform ventilator selection commensurate with disease severity and progression.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/19433654261476549","type":"journal-article","created":{"date-parts":[[2026,9,2]],"date-time":"2026-09-02T13:32:31Z","timestamp":1788355951000},"update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":0,"title":["Firmware-Dependent Changes in Pressurization and Tidal Volume Delivery During Passive Leak Ventilation"],"prefix":"10.1177","author":[{"ORCID":"https:\/\/orcid.org\/0009-0001-0619-0795","authenticated-orcid":false,"given":"Satoshi","family":"Abe","sequence":"first","affiliation":[{"name":"Mr. Abe and Mr. Wada are affiliated with the National Hospital Organization Nishi-Beppu Hospital, Beppu, Japan."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masaya","family":"Wada","sequence":"additional","affiliation":[{"name":"Mr. Abe and Mr. Wada are affiliated with the National Hospital Organization Nishi-Beppu Hospital, Beppu, Japan."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tetsuo","family":"Miyagawa","sequence":"additional","affiliation":[{"name":"Prof. Miyagawa is affiliated with the Kochi Professional University of Rehabilitation, Tosa, Japan."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuka","family":"Ishikawa","sequence":"additional","affiliation":[{"name":"Dr. Ishikawa is affiliated with the Center for Neuromuscular Disease, Child Health and Development, National Hospital Organization Hokkaido Medical Center, Sapporo, Japan."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2026,9,2]]},"reference":[{"key":"e_1_3_2_2_1","doi-asserted-by":"publisher","DOI":"10.1164\/rccm.200307-885ST"},{"key":"e_1_3_2_3_1","doi-asserted-by":"publisher","DOI":"10.1055\/s-0043-118040"},{"key":"e_1_3_2_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.chest.2023.03.011"},{"key":"e_1_3_2_5_1","doi-asserted-by":"publisher","DOI":"10.1164\/rccm.201210-1804CI"},{"key":"e_1_3_2_6_1","doi-asserted-by":"publisher","DOI":"10.4187\/respcare.07520301"},{"key":"e_1_3_2_7_1","doi-asserted-by":"publisher","DOI":"10.1378\/chest.127.5.1784"},{"key":"e_1_3_2_8_1","doi-asserted-by":"publisher","DOI":"10.1034\/j.1399-3003.2000.15b20.x"},{"key":"e_1_3_2_9_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00134-010-1785-9"},{"key":"e_1_3_2_10_1","doi-asserted-by":"publisher","DOI":"10.1177\/1479972316647177"},{"key":"e_1_3_2_11_1","doi-asserted-by":"publisher","DOI":"10.21037\/jtd.2016.12.64"},{"key":"e_1_3_2_12_1","doi-asserted-by":"publisher","DOI":"10.4187\/respcare.01176"},{"key":"e_1_3_2_13_1","doi-asserted-by":"publisher","DOI":"10.4187\/respcare.08650"},{"key":"e_1_3_2_14_1","doi-asserted-by":"publisher","DOI":"10.1136\/bmjresp-2025-003532"},{"key":"e_1_3_2_15_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00134-011-2416-9"},{"key":"e_1_3_2_16_1","doi-asserted-by":"publisher","DOI":"10.1183\/23120541.00163-2023"},{"key":"e_1_3_2_17_1","doi-asserted-by":"publisher","DOI":"10.1183\/09031936.00037209"},{"key":"e_1_3_2_18_1","doi-asserted-by":"publisher","DOI":"10.1177\/19433654251391165"},{"key":"e_1_3_2_19_1","doi-asserted-by":"publisher","DOI":"10.1378\/chest.11-2279"},{"key":"e_1_3_2_20_1","first-page":"1388","article-title":"Prevalence and consequences of patient\u2013ventilator interactions in a cohort of home-ventilated restrictive and neuromuscular patients: A multicentre study","volume":"11","author":"Mart\u00ednez-Castro S","year":"2025","unstructured":"19.Mart\u00ednez-Castro S, , Gonz\u00e1lez-Bermejo J, , Luj\u00e1n M, et al. Prevalence and consequences of patient\u2013ventilator interactions in a cohort of home-ventilated restrictive and neuromuscular patients: A multicentre study. ERJ Open Res 2025; 11: 1388\u20132024.","journal-title":"ERJ Open Res"}],"container-title":["Respiratory Care"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/19433654261476549","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/19433654261476549","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/19433654261476549","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T12:20:01Z","timestamp":1788524401000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/19433654261476549"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,2]]},"references-count":19,"alternative-id":["10.1177\/19433654261476549"],"URL":"https:\/\/doi.org\/10.1177\/19433654261476549","relation":{},"ISSN":["1943-3654","1943-3654"],"issn-type":[{"value":"1943-3654","type":"print"},{"value":"1943-3654","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,2]]},"article-number":"19433654261476549"}}