{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,12]],"date-time":"2026-09-12T00:13:37Z","timestamp":1789172017899,"version":"build-2803163510"},"reference-count":31,"publisher":"SAGE Publications","issue":"2","license":[{"start":{"date-parts":[[2024,3,1]],"date-time":"2024-03-01T00:00:00Z","timestamp":1709251200000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"},{"start":{"date-parts":[[2024,3,1]],"date-time":"2024-03-01T00:00:00Z","timestamp":1709251200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"funder":[{"DOI":"10.13039\/100012630","name":"Zimmer Biomet","doi-asserted-by":"publisher","award":["149451057A"],"award-info":[{"award-number":["149451057A"]}],"id":[{"id":"10.13039\/100012630","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["CARTILAGE"],"published-print":{"date-parts":[[2025,6]]},"abstract":"<jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>Newer all-suture, all-inside meniscus repair devices utilize soft suture anchors. The purpose of this study was to compare the biomechanical performance of 4 meniscus repair devices in human cadaver menisci: the JuggerStitch (all-suture, all-inside), the FiberStitch (all-suture, all-inside), a polyether ether ketone (PEEK) all-inside, and an inside-out device.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Design<\/jats:title>\n                    <jats:p>\n                      Forty human cadaver menisci were tested after creating 20 mm longitudinal tears in the posterior meniscus. Each knee was randomized to 1 of 4 meniscus repair groups: JuggerStitch (all-suture, all-inside), FiberStitch (all-suture, all-inside), FAST-FIX 360 (PEEK-based anchor all-inside), and inside-out (with Broadband\n                      <jats:sup>TM<\/jats:sup>\n                      tape meniscus needles). For each meniscus, 2 devices were used to prepare vertical mattress repair construct. The specimens were tested by pre-conditioning 20 cycles between 5 N and 30 N and then the tear diastasis was measured, followed by distraction to failure phase after imposing a displacement at a rate of 0.5 mm\/s.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Ten menisci were tested in each of the 4 groups. After pre-conditioning, there was no significant difference in the gap formation among groups (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.212). The average failure load for the JuggerStitch, FiberStitch, PEEK all-inside, and inside-out was 384 N, 311 N, 207 N, and 261 N, respectively, with a significant difference between groups (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.034).\n                      <jats:italic toggle=\"yes\">Post hoc<\/jats:italic>\n                      analysis showed the JuggerStitch failure load was higher than the PEEK all-inside and inside-out (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.005, and\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.045, respectively). There was no significant difference between the failure load of the JuggerStitch and FiberStitch (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.225).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>The JuggerStitch all-suture device, FiberStitch all-suture device, PEEK all-inside, and inside-out devices have similar biomechanical properties for gapping and stiffness. The JuggerStitch all-suture, all-inside device has superior failure load compared with the PEEK all-inside and inside-out repair for longitudinal meniscus tear repair.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/19476035241234315","type":"journal-article","created":{"date-parts":[[2024,3,1]],"date-time":"2024-03-01T06:34:30Z","timestamp":1709274870000},"page":"150-158","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":9,"title":["Biomechanical Comparison of All-Suture, All-Inside Meniscus Repair Devices in a Human Cadaveric Meniscus Model"],"prefix":"10.1177","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8637-0122","authenticated-orcid":false,"given":"Patrick A.","family":"Massey","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery, Louisiana State University Health Sciences Center Shreveport, Shreveport, LA, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wayne","family":"Scalisi","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Louisiana State University Health Sciences Center Shreveport, Shreveport, LA, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carver","family":"Montgomery","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Louisiana State University Health Sciences Center Shreveport, Shreveport, LA, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Drayton","family":"Daily","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Louisiana State University Health Sciences Center Shreveport, Shreveport, LA, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James","family":"Robinson","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Louisiana State University Health Sciences Center Shreveport, Shreveport, LA, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giovanni F.","family":"Solitro","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Louisiana State University Health Sciences Center Shreveport, Shreveport, LA, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2024,3]]},"reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1177\/2325967116640263"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1177\/0363546513490276"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2020.03.036"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2019.04.009"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2019.08.045"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2019.03.002"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2016.03.029"},{"issue":"3","key":"e_1_3_2_9_2","article-title":"In-vitro measurement of static pressure distribution in synovial joints\u2014part I: tibial surface of the knee","volume":"105","author":"Ahmed AM","year":"1983","unstructured":"Ahmed AM, Burke DL. In-vitro measurement of static pressure distribution in synovial joints\u2014part I: tibial surface of the knee. J Biomech Eng. 1983;105(3):216-25.","journal-title":"J Biomech Eng"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/0141-5425(83)90036-5"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.66B5.6548755"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.74B1.1732238"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1177\/0363546516632504"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2009.03.020"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1177\/0363546511411701"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2014.05.023"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2015.07.017"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2019.02.010"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2017.11.009"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0749-8063(97)90120-1"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2018.11.039"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2005.12.009"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1177\/0363546514549445"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1038\/nmeth.2089"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2017.04.013"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1177\/0363546511424723"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1177\/2325967117717010"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.4103\/0973-6042.161440"},{"key":"e_1_3_2_29_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2014.08.027"},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.1177\/0363546514538394"},{"issue":"1","key":"e_1_3_2_31_2","article-title":"A biomechanical evaluation of all-inside 2-stitch Meniscal repair devices with matched inside-out suture repair","volume":"42","author":"Ramappa AJ","year":"2014","unstructured":"Ramappa AJ, Chen A, Hertz B, Wexler M, Grimaldi Bournissaint L, DeAngelis JP et al. A biomechanical evaluation of all-inside 2-stitch Meniscal repair devices with matched inside-out suture repair. Am J Sports Med. 2014;42(1):194-9.","journal-title":"et al."},{"key":"e_1_3_2_32_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.biomaterials.2011.06.037"}],"container-title":["CARTILAGE"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/19476035241234315","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/19476035241234315","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/19476035241234315","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T14:03:29Z","timestamp":1777385009000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/19476035241234315"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,3]]},"references-count":31,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2025,6]]}},"alternative-id":["10.1177\/19476035241234315"],"URL":"https:\/\/doi.org\/10.1177\/19476035241234315","relation":{},"ISSN":["1947-6035","1947-6043"],"issn-type":[{"value":"1947-6035","type":"print"},{"value":"1947-6043","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,3]]}}}