{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,4]],"date-time":"2026-05-04T07:46:55Z","timestamp":1777880815267,"version":"3.51.4"},"reference-count":50,"publisher":"SAGE Publications","license":[{"start":{"date-parts":[[2022,1,1]],"date-time":"2022-01-01T00:00:00Z","timestamp":1640995200000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["SAGE Open Medicine"],"published-print":{"date-parts":[[2022,1]]},"abstract":"<jats:sec>\n                    <jats:title>Objective:<\/jats:title>\n                    <jats:p>\n                      In the delivery of intravenous fluids, in-line warming devices frequently transfer heat using a metal heating plate, which if uncoated can risk elution. This bench study examined extractable elements detected following long-term use of the parylene-coated enFlow\n                      <jats:sup>\u00ae<\/jats:sup>\n                      Disposable IV\/Blood Warmer.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>\n                      We tested 16 clinically relevant challenge fluids typical of the surgical setting, including commercially available single donor blood and blood products as well as intravenous saline and electrolyte solutions. After 72\u2009h of warming at 40\u00b0C (104\u00b0F) via the enFlow, analytical chemistry identified and quantified the most clinically significant extractable elements (arsenic, barium, cadmium, copper, and lead) to estimate chemical exposure. We also measured the extracted concentrations of these five elements following simulated use of the device with three solutions (Sterofundin ISO, Plasma-Lyte 148, and whole blood) that were pumped through the warmed device at two different flow rates (0.2 and 5.5\u2009mL\u2009min\n                      <jats:sup>\u22121<\/jats:sup>\n                      ).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>Across all scenarios of acute and long-term exposures for different populations, the enFlow demonstrated low toxicological risks as measured by the calculation of tolerable exposure for extracted arsenic, barium, cadmium, copper, and lead.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>The results suggest biological safety for the use of parylene-coated enFlow with a variety of intravenous solutions and in different therapeutic scenarios.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/20503121221108927","type":"journal-article","created":{"date-parts":[[2022,7,6]],"date-time":"2022-07-06T02:43:43Z","timestamp":1657075423000},"update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":0,"title":["Levels of leachable elements from long-term use of enFlow fluid warmer"],"prefix":"10.1177","volume":"10","author":[{"given":"Danielle","family":"Bayoro","sequence":"first","affiliation":[{"name":"Medical Affairs, Vyaire Medical, Mettawa, IL, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Herman","family":"Groepenhoff","sequence":"additional","affiliation":[{"name":"Medical Affairs, Vyaire Medical, Mettawa, IL, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael","family":"Pedro","sequence":"additional","affiliation":[{"name":"Medical Affairs, Vyaire Medical, Mettawa, IL, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7086-8639","authenticated-orcid":false,"given":"Edward A","family":"Rose","sequence":"additional","affiliation":[{"name":"Medical Affairs, Vyaire Medical, Mettawa, IL, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andreas D","family":"Waldmann","sequence":"additional","affiliation":[{"name":"Medical Affairs, Vyaire Medical, Mettawa, IL, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2022,7,5]]},"reference":[{"key":"bibr1-20503121221108927","doi-asserted-by":"publisher","DOI":"10.1111\/j.1744-1609.2011.00227.x"},{"key":"bibr2-20503121221108927","unstructured":"National Institute for Health Care Excellence. Hypothermia: prevention and management in adults having surgery. NICE Clinical Guideline, No. 65 [CG65], 2016, https:\/\/www.ncbi.nlm.nih.gov\/books\/NBK554181\/"},{"key":"bibr3-20503121221108927","doi-asserted-by":"publisher","DOI":"10.1097\/00043860-199510000-00018"},{"key":"bibr4-20503121221108927","first-page":"643","volume-title":"Integrated safety and risk assessment for medical devices and combination products","author":"Napier KM","year":"2020"},{"key":"bibr5-20503121221108927","unstructured":"Food Drug Administration. Potential risk of aluminum leaching with use of certain fluid warmer devices\u2014letter to health care providers, https:\/\/www.fda.gov\/medical-devices\/letters-health-care-providers\/potential-risk-aluminum-leaching-use-certain-fluid-warmer-devices-letter-health-care-providers (2021, accessed 20 September 2021)."},{"key":"bibr6-20503121221108927","unstructured":"Food Drug Administration. Vyaire medical recalls the enFlow fluid warming system disposable cartridges due to potential risk of exposure to elevated levels of aluminium exposure to patients, 2019, https:\/\/www.fda.gov\/medical-devices\/medical-device-recalls\/vyaire-medical-recalls-enflow-fluid-warming-system-disposable-cartridges-due-potential-risk-exposure (accessed 1 January 2022)."},{"key":"bibr7-20503121221108927","unstructured":"Food Drug Administration. Eight medical international recalls recirculator 8.0 disposable lavage kits due to potential exposure to high levels of aluminum, https:\/\/www.fda.gov\/medical-devices\/medical-device-recalls\/eight-medical-international-recalls-recirculator-80-disposable-lavage-kits-due-potential-exposure (2021, accessed 5 January 2022)."},{"key":"bibr8-20503121221108927","unstructured":"Curtiss-Wright Corporation. Parylene history: history of parylene technology, https:\/\/www.parylene.com\/Parylene-Technology\/Parylene-History (2019, accessed 2 September 2020)."},{"key":"bibr9-20503121221108927","doi-asserted-by":"publisher","DOI":"10.1177\/20503121211026849"},{"key":"bibr10-20503121221108927","doi-asserted-by":"publisher","DOI":"10.1186\/s12871-022-01585-w"},{"key":"bibr11-20503121221108927","doi-asserted-by":"publisher","DOI":"10.1111\/anae.15013"},{"key":"bibr12-20503121221108927","doi-asserted-by":"publisher","DOI":"10.1111\/anae.14743"},{"key":"bibr13-20503121221108927","unstructured":"Medicines Healthcare products Regulatory Agency. enFlow\u00ae IV fluid and blood warmer\u2014risk of unsafe levels of aluminium leaching from the device (MDA\/2019\/015). https:\/\/www.gov.uk\/drug-device-alerts\/enflow-iv-fluid-and-blood-warmer-risk-of-unsafe-levels-of-aluminium-leaching-from-the-device-mda-2019-015 (2019, accessed 14 December 2021)."},{"key":"bibr14-20503121221108927","doi-asserted-by":"publisher","DOI":"10.1186\/s12871-021-01378-7"},{"key":"bibr15-20503121221108927","doi-asserted-by":"publisher","DOI":"10.1111\/anae.15020"},{"key":"bibr16-20503121221108927","volume":"364","author":"Pike H.","year":"2019","journal-title":"British Med J"},{"key":"bibr17-20503121221108927","doi-asserted-by":"publisher","DOI":"10.1111\/anae.14697"},{"key":"bibr18-20503121221108927","unstructured":"Food Drug Administration. Q3D elemental impurities guidance for industry. U.S. Department of Health and Human Services, 2015, https:\/\/www.fda.gov\/media\/135956\/download"},{"key":"bibr19-20503121221108927","doi-asserted-by":"publisher","DOI":"10.1080\/10408440802291505"},{"key":"bibr20-20503121221108927","volume-title":"Arsenic, metals, fibres and dusts (IARC monographs on the evaluation of carcinogenic risks to humans)","author":"International Agency for Research on Cancer","year":"2012"},{"key":"bibr21-20503121221108927","unstructured":"National Toxicology Program. Technical report on toxicity studies of Cadmium Oxide (CAS no. 1306-19-0) administered by inhalation to F344\/N rats and B6C3F1 Mice. Research Triangle Park, US Department of Health and Human Services; Public Health Service; National Institutes of Health NIH Publication 1995, https:\/\/ntp.niehs.nih.gov\/ntp\/htdocs\/st_rpts\/tox039.pdf?utm_source=direct&utm_medium=prod&utm_campaign=ntpgolinks&utm_term=tox039"},{"key":"bibr22-20503121221108927","doi-asserted-by":"crossref","unstructured":"Morrow H. Cadmium and Cadmium Alloys. Kirk-othmer Encyclopedia of Chemical Technology. Hoboken, NJ: John Wiley & Sons, 2010, pp. 1\u201336.","DOI":"10.1002\/0471238961.0301041303011818.a01.pub3"},{"key":"bibr23-20503121221108927","doi-asserted-by":"publisher","DOI":"10.1016\/j.envint.2018.08.013"},{"key":"bibr24-20503121221108927","unstructured":"Centers for Disease Control. Blood lead reference value, https:\/\/www.cdc.gov\/nceh\/lead\/data\/blood-lead-reference-value.htm (2021, accessed 17 February 2022)."},{"key":"bibr25-20503121221108927","doi-asserted-by":"publisher","DOI":"10.3109\/15563650.2014.923903"},{"key":"bibr26-20503121221108927","first-page":"1","volume":"432","author":"National Toxicology Program","year":"1994","journal-title":"Natl Toxicol Program Tech Rep Ser"},{"key":"bibr27-20503121221108927","doi-asserted-by":"publisher","DOI":"10.1016\/j.tips.2018.10.001"},{"key":"bibr28-20503121221108927","doi-asserted-by":"publisher","DOI":"10.1007\/s00267-019-01234-y"},{"key":"bibr29-20503121221108927","doi-asserted-by":"publisher","DOI":"10.1093\/ajcn\/77.3.646"},{"key":"bibr30-20503121221108927","doi-asserted-by":"publisher","DOI":"10.1111\/anae.14601"},{"key":"bibr31-20503121221108927","unstructured":"Food Drug Administration. Use of International Standard ISO 10993-1, biological evaluation of medical devices\u2014part 1: evaluation and testing within a risk management process, 2016, https:\/\/www.fda.gov\/regulatory-information\/search-fda-guidance-documents\/use-international-standard-iso-10993-1-biological-evaluation-medical-devices-part-1-evaluation-and (2017, accessed 9 October 2020)."},{"key":"bibr32-20503121221108927","unstructured":"ISO 10993-18:2005. Biological evaluation of medical devices\u2014Part 18: Chemical characterization of materials."},{"key":"bibr33-20503121221108927","unstructured":"United States Environmental Protection Agency. Definition and procedure for the determination of the method detection limit, Revision 2, https:\/\/www.epa.gov\/sites\/production\/files\/2016-12\/documents\/mdl-procedure_rev2_12-13-2016.pdf (2016, accessed 22 March 2021)."},{"key":"bibr34-20503121221108927","unstructured":"ISO 10993-17: 2002. Biological evaluation of medical devices\u2013 part 17: establishment of allowable limits for leachable substances."},{"key":"bibr35-20503121221108927","doi-asserted-by":"publisher","DOI":"10.1186\/s12199-020-00855-8"},{"key":"bibr36-20503121221108927","doi-asserted-by":"publisher","DOI":"10.1016\/j.joen.2005.10.043"},{"key":"bibr37-20503121221108927","doi-asserted-by":"publisher","DOI":"10.3892\/etm.2017.4106"},{"key":"bibr38-20503121221108927","doi-asserted-by":"publisher","DOI":"10.1080\/13645700902718989"},{"key":"bibr39-20503121221108927","first-page":"1219","volume-title":"In: IEEE 71st Electronic Components and Technology Conference (ECTC)","author":"Sayeed SYB"},{"key":"bibr40-20503121221108927","doi-asserted-by":"publisher","DOI":"10.1097\/JCE.0000000000000114"},{"key":"bibr41-20503121221108927","doi-asserted-by":"publisher","DOI":"10.1007\/s13534-011-0033-8"},{"key":"bibr42-20503121221108927","doi-asserted-by":"publisher","DOI":"10.1016\/j.msec.2017.03.149"},{"key":"bibr43-20503121221108927","doi-asserted-by":"publisher","DOI":"10.1016\/j.colsurfb.2020.111154"},{"key":"bibr44-20503121221108927","doi-asserted-by":"publisher","DOI":"10.1016\/j.jeurceramsoc.2014.12.013"},{"key":"bibr45-20503121221108927","doi-asserted-by":"publisher","DOI":"10.1016\/j.sna.2021.112649"},{"key":"bibr46-20503121221108927","doi-asserted-by":"publisher","DOI":"10.1016\/j.tox.2006.06.010"},{"key":"bibr47-20503121221108927","unstructured":"Nordberg GF, Fowler BA, Nordberg M. Handbook on the toxicology of metals. Cambridge, MA: Academic Press, 2014, pp. 625\u2013634."},{"key":"bibr48-20503121221108927","doi-asserted-by":"publisher","DOI":"10.1080\/00039896.1983.10543998"},{"issue":"2","key":"bibr49-20503121221108927","first-page":"213","volume":"42","author":"Buxaderas SC","year":"1986","journal-title":"Rev Esp Fisiol"},{"key":"bibr50-20503121221108927","doi-asserted-by":"publisher","DOI":"10.1038\/jes.2013.4"}],"container-title":["SAGE Open Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/20503121221108927","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/20503121221108927","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/20503121221108927","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T00:23:18Z","timestamp":1777594998000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/20503121221108927"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,1]]},"references-count":50,"alternative-id":["10.1177\/20503121221108927"],"URL":"https:\/\/doi.org\/10.1177\/20503121221108927","relation":{},"ISSN":["2050-3121","2050-3121"],"issn-type":[{"value":"2050-3121","type":"print"},{"value":"2050-3121","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,1]]},"article-number":"20503121221108927"}}