{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,17]],"date-time":"2026-07-17T15:26:14Z","timestamp":1784301974552,"version":"3.55.0"},"reference-count":24,"publisher":"SAGE Publications","issue":"7","license":[{"start":{"date-parts":[[2022,7,1]],"date-time":"2022-07-01T00:00:00Z","timestamp":1656633600000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Acta Radiologica Open"],"published-print":{"date-parts":[[2022,7]]},"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Cardiothoracic ratio (CTR) is the ratio of the diameter of the heart to the diameter of the thorax. An abnormal CTR (&gt;0.55) is often an indicator of an underlying pathological condition. The accurate prediction of an abnormal CTR chest X-rays (CXRs) aids in the early diagnosis of clinical conditions.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>We propose a deep learning (DL)-based model for automatic CTR calculation to assist radiologists with rapid diagnosis of cardiomegaly and thus optimise the radiology flow.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Material and Methods<\/jats:title>\n                    <jats:p>The study population included 1012 posteroanterior CXRs from a single institution. The Attention U-Net DL architecture was used for the automatic calculation of CTR. An observer performance test was conducted to assess the radiologist\u2019s performance in diagnosing cardiomegaly with and without artificial intelligence assistance.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>U-Net model exhibited a sensitivity of 0.80 [95% CI: 0.75, 0.85], specificity &gt;99%, precision of 0.99 [95% CI: 0.98, 1], and a F1 score of 0.88 [95% CI: 0.85, 0.91]. Furthermore, the sensitivity of the reviewing radiologist in identifying cardiomegaly increased from 40.50% to 88.4% when aided by the AI-generated CTR.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Our segmentation-based AI model demonstrated high specificity (&gt;99%) and sensitivity (80%) for CTR calculation. The performance of the radiologist on the observer performance test improved significantly with provision of AI assistance. A DL-based segmentation model for rapid quantification of CTR can therefore have significant potential to be used in clinical workflows by reducing radiologists\u2019 burden and alerting to an abnormal enlarged heart early on.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/20584601221107345","type":"journal-article","created":{"date-parts":[[2022,7,21]],"date-time":"2022-07-21T09:52:07Z","timestamp":1658397127000},"update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":19,"title":["Observer performance evaluation of the feasibility of a deep learning model to detect cardiomegaly on chest radiographs"],"prefix":"10.1177","volume":"11","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8801-0235","authenticated-orcid":false,"given":"Pranav","family":"Ajmera","sequence":"first","affiliation":[{"name":"Department of Radiodiagnosis, Dr DY Patil Medical College, Hospital and Research Center, DY Patil Vidyapeeth, DPU, Pune, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amit","family":"Kharat","sequence":"additional","affiliation":[{"name":"Department of Radiodiagnosis, Dr DY Patil Medical College, Hospital and Research Center, DY Patil Vidyapeeth, DPU, Pune, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tanveer","family":"Gupte","sequence":"additional","affiliation":[{"name":"DeepTek Medical Imaging Pvt. Ltd, Pune, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Richa","family":"Pant","sequence":"additional","affiliation":[{"name":"DeepTek Medical Imaging Pvt. Ltd, Pune, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Viraj","family":"Kulkarni","sequence":"additional","affiliation":[{"name":"DeepTek Medical Imaging Pvt. Ltd, Pune, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4808-5715","authenticated-orcid":false,"given":"Vinay","family":"Duddalwar","sequence":"additional","affiliation":[{"name":"Department of Radiology and Biomedical Imaging, Keck School of Medicine, University of Southern California, Los Angeles, CA, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Purnachandra","family":"Lamghare","sequence":"additional","affiliation":[{"name":"Department of Radiodiagnosis, Dr DY Patil Medical College, Hospital and Research Center, DY Patil Vidyapeeth, DPU, Pune, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2022,7,21]]},"reference":[{"key":"bibr1-20584601221107345","first-page":"574","volume":"56","author":"Speets AM","year":"2006","journal-title":"Br Journal General Practice : The Journal R Coll Gen Pract"},{"key":"bibr2-20584601221107345","doi-asserted-by":"publisher","DOI":"10.1186\/s13244-021-01097-0"},{"key":"bibr3-20584601221107345","doi-asserted-by":"publisher","DOI":"10.1001\/archinte.158.5.501"},{"key":"bibr4-20584601221107345","first-page":"201","volume":"27","author":"Brakohiapa EKK","year":"2017","journal-title":"Pan Afr Medical Journal"},{"key":"bibr5-20584601221107345","unstructured":"https:\/\/www.telemedicineclinic.com\/wp-content\/uploads\/2016\/11\/Europes_looming_radiology_capacity_challenge-A_comparitive_study.pdf (Accessed: 20th November,2021)."},{"key":"bibr6-20584601221107345","first-page":"1","volume":"25","author":"Iyawe EP","year":"2021","journal-title":"SA J Radiol"},{"key":"bibr7-20584601221107345","doi-asserted-by":"publisher","DOI":"10.1016\/j.media.2021.102125"},{"key":"bibr8-20584601221107345","doi-asserted-by":"publisher","DOI":"10.1067\/j.cpradiol.2014.09.003"},{"key":"bibr9-20584601221107345","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.j4683"},{"key":"bibr10-20584601221107345","doi-asserted-by":"crossref","unstructured":"Gupte T, Niljikar M, Gawali M, Kulkarni V, Kharat A, Pant A. Deep learning models for calculation of cardiothoracic ratio from chest radiographs for assisted diagnosis of cardiomegaly. In: 2021 International Conference on Artificial Intelligence, Big Data, Computing and Data Communication Systems (icABCD), 5 August 2021 (pp. 1\u20136). IEEE.","DOI":"10.1109\/icABCD51485.2021.9519348"},{"key":"bibr11-20584601221107345","unstructured":"Oktay O, Schlemper J, Folgoc LL, et al. Attention u-net: Learning where to look for the pancreas. arXiv preprint 2018 :1804.03999."},{"key":"bibr12-20584601221107345","doi-asserted-by":"publisher","DOI":"10.3390\/app10175729"},{"key":"bibr13-20584601221107345","first-page":"7132","volume":"2018","author":"Hu J","year":"2018","journal-title":"IEEE\/CVF Conf Comp Vis Pattern Recognition"},{"key":"bibr14-20584601221107345","doi-asserted-by":"crossref","unstructured":"Xie S, Girshick R, Doll\u00e1r P, et al. Aggregated residual transformations for deep neural networks. In: InProceedings of the IEEE conference on computer vision and pattern recognition, Honolulu, HI, USA, 21\u201326 July 2017, 1492\u20131500.","DOI":"10.1109\/CVPR.2017.634"},{"key":"bibr15-20584601221107345","first-page":"6105","volume-title":"InInternational Conf Machine Learn","volume":"24","author":"Tan M","year":"2019"},{"key":"bibr16-20584601221107345","first-page":"358","volume":"2016","author":"Baheti B","year":"2020","journal-title":"InProceedings IEEE\/CVF Conf Comp Vis Pattern Recognition Workshops"},{"key":"bibr17-20584601221107345","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijcard.2011.10.125"},{"key":"bibr18-20584601221107345","doi-asserted-by":"publisher","DOI":"10.5551\/jat.36426"},{"key":"bibr19-20584601221107345","doi-asserted-by":"publisher","DOI":"10.3390\/jcm9030871"},{"key":"bibr20-20584601221107345","doi-asserted-by":"publisher","DOI":"10.1109\/ACCESS.2019.2900053"},{"key":"bibr21-20584601221107345","first-page":"612","volume":"2018","author":"Que Q","year":"2018","journal-title":"Annu Int Conf IEEE Eng Med Biol Soc IEEE Eng Med Biol Soc Annu Int Conf"},{"key":"bibr22-20584601221107345","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-021-96433-1"},{"key":"bibr23-20584601221107345","doi-asserted-by":"publisher","DOI":"10.1186\/s12880-021-00625-0"},{"key":"bibr24-20584601221107345","volume-title":"Automated Cardiothoracic Ratio Calculation and Cardiomegaly Detection Using Deep Learning Approach","author":"Chamveha I","year":"2002"}],"container-title":["Acta Radiologica Open"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/20584601221107345","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/20584601221107345","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/20584601221107345","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T11:54:54Z","timestamp":1777377294000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/20584601221107345"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,7]]},"references-count":24,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2022,7]]}},"alternative-id":["10.1177\/20584601221107345"],"URL":"https:\/\/doi.org\/10.1177\/20584601221107345","relation":{},"ISSN":["2058-4601","2058-4601"],"issn-type":[{"value":"2058-4601","type":"print"},{"value":"2058-4601","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,7]]},"article-number":"20584601221107345"}}