{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T03:56:10Z","timestamp":1777434970899,"version":"3.51.4"},"reference-count":11,"publisher":"SAGE Publications","issue":"5","license":[{"start":{"date-parts":[[2025,5,1]],"date-time":"2025-05-01T00:00:00Z","timestamp":1746057600000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"},{"start":{"date-parts":[[2025,5,1]],"date-time":"2025-05-01T00:00:00Z","timestamp":1746057600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Acta Radiologica Open"],"published-print":{"date-parts":[[2025,5]]},"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>There have been no previous studies comparing the effectiveness of echo-planar imaging (EPI)-diffusion-weighted imaging (DWI) and turbo spin echo (TSE)-DWI for female pelvic imaging on 1.5T and 3.0T magnetic resonance imaging (MRI) systems.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>This retrospective study compared EPI-DWI and TSE-DWI of the female pelvis at 1.5T and 3.0T MRI to evaluate image quality, geometric distortion, and apparent diffusion coefficient (ADC) values for optimal clinical diagnosis.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and methods<\/jats:title>\n                    <jats:p>\n                      Thirty-nine patients at 1.5T and 71 patients at 3.0T underwent both TSE- and EPI-DWI with b-values of 0 and 1000 s\/mm\n                      <jats:sup>2<\/jats:sup>\n                      . Spatial resolution was matched between systems and sequences. Geometric distortion, contrast ((uterine myometrium signal intensity (SI) \u2212 gluteal muscle SI)\/(uterine myometrium SI + gluteal muscles SI)), and ADC values of the uterine myometrium and lesions were compared. Qualitative assessment included ghosting artifacts, image contrast, and overall image quality.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      There was no significant difference in patient demographics between 1.5T and 3.0T groups. TSE-DWI demonstrated significantly less distortion than EPI-DWI at both field strengths (\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      &lt; .05). Contrast was higher with TSE-DWI than EPI-DWI at 3.0T (\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      &lt; .05) and was greater at 3.0T than 1.5T. ADC values of malignancies differed significantly from the uterus and benign lesions across all sequences and field strengths (\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      &lt; .05). TSE-DWI showed higher ghosting artifact scores than EPI-DWI at 3.0T (\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      = .019), but no other significant differences in qualitative evaluation were noted.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>TSE-DWI provided superior contrast with reduced distortion compared to EPI-DWI in the female pelvis at both field strengths, with TSE-DWI demonstrating greater effectiveness at 3.0T.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/20584601251339018","type":"journal-article","created":{"date-parts":[[2025,5,2]],"date-time":"2025-05-02T15:00:42Z","timestamp":1746198042000},"update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":0,"title":["Comparisons of turbo spin-echo and echo-planar diffusion-weighted imaging of the female pelvic region on 1.5T and 3.0T magnetic resonance systems"],"prefix":"10.1177","volume":"14","author":[{"given":"Hisatoshi","family":"Araki","sequence":"first","affiliation":[{"name":"Shimane University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1623-1375","authenticated-orcid":false,"given":"Takeshi","family":"Yoshizako","sequence":"additional","affiliation":[{"name":"Shimane University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9157-643X","authenticated-orcid":false,"given":"Rika","family":"Yoshida","sequence":"additional","affiliation":[{"name":"Shimane University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8120-4034","authenticated-orcid":false,"given":"Hiroya","family":"Asou","sequence":"additional","affiliation":[{"name":"Shimane University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yasushi","family":"Kaji","sequence":"additional","affiliation":[{"name":"Shimane University"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2025,5,2]]},"reference":[{"key":"e_1_3_5_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.mri.2010.07.013"},{"key":"e_1_3_5_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.acra.2018.11.016"},{"key":"e_1_3_5_4_2","doi-asserted-by":"publisher","DOI":"10.1097\/MD.0000000000010447"},{"key":"e_1_3_5_5_2","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A4930"},{"key":"e_1_3_5_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.nic.2006.02.005"},{"key":"e_1_3_5_7_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.28824"},{"key":"e_1_3_5_8_2","doi-asserted-by":"publisher","DOI":"10.1177\/2058460121994737"},{"key":"e_1_3_5_9_2","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2282011860"},{"key":"e_1_3_5_10_2","first-page":"425","article-title":"Diffusion MRI: from physics to medicine","volume":"19","author":"Le Bihan D","year":"2001","unstructured":"Le Bihan D, Mangin JF, Poupon C, et al. Diffusion MRI: from physics to medicine. Magn Reson Imaging 2001; 19: 425\u2013454.","journal-title":"Magn Reson Imaging"},{"key":"e_1_3_5_11_2","first-page":"503","article-title":"Optimal strategies for diffusion tensor imaging in human brain","volume":"17","author":"Jones DK","year":"1999","unstructured":"Jones DK, Horsfield MA, Simmons A. Optimal strategies for diffusion tensor imaging in human brain. Magn Reson Imaging 1999; 17: 503\u2013514.","journal-title":"Magn Reson Imaging"},{"key":"e_1_3_5_12_2","first-page":"123","article-title":"Motion artifact reduction in DWI: a comparative study of TSE-DWI and EPI-DWI","volume":"287","author":"Brown EF","year":"2018","unstructured":"Brown EF, Garcia GH. Motion artifact reduction in DWI: a comparative study of TSE-DWI and EPI-DWI. Radiology 2018; 287: 123\u2013131.","journal-title":"Radiology"}],"container-title":["Acta Radiologica Open"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/20584601251339018","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/20584601251339018","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/20584601251339018","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T11:55:12Z","timestamp":1777377312000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/20584601251339018"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5]]},"references-count":11,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2025,5]]}},"alternative-id":["10.1177\/20584601251339018"],"URL":"https:\/\/doi.org\/10.1177\/20584601251339018","relation":{},"ISSN":["2058-4601","2058-4601"],"issn-type":[{"value":"2058-4601","type":"print"},{"value":"2058-4601","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5]]},"article-number":"20584601251339018"}}