{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T03:55:54Z","timestamp":1777434954967,"version":"3.51.4"},"reference-count":20,"publisher":"SAGE Publications","issue":"10","license":[{"start":{"date-parts":[[2025,10,1]],"date-time":"2025-10-01T00:00:00Z","timestamp":1759276800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"},{"start":{"date-parts":[[2025,10,1]],"date-time":"2025-10-01T00:00:00Z","timestamp":1759276800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Acta Radiologica Open"],"published-print":{"date-parts":[[2025,10]]},"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Bedside insertion of peripherally inserted central venous catheter (PICC) is still needed in the various clinical settings. For this procedure, the accuracy of predicting the PICC catheter length is important, however, only a few methods have been proposed so far.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>A new formula using pre-procedural chest X ray (pre-CXR) was validated for placing the PICC catheter tip precisely in the actual clinical setting.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Material and Methods<\/jats:title>\n                    <jats:p>The formula predicting the PICC catheter length was formed by the hybrids of the calculated expression in the thorax and the actual measurement of the outer arm. The predicted length in the thorax was based on the half ellipse formed by the three landmarks on the pre-CXR. Prospectively, this formula was applied in the 110 patients. The results were compared to those in the traditional anthropometrical measurements (TAM) in the 48 patients.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      The discrepancy of the catheter distance from the carina and the variance of the tip position were smaller by using the Formula than by the TAM (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .00053 and\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .038). Comparing to the other patient\u2019s valuables, the Formula had the strongest correlation coefficient with the true PICC length (r = 0.787). Evaluation of validation success showed that the tip position was \u201coptimal\u201d in 79 cases (71.8%) and \u201csuboptimal\u201d in 26 cases (23.6%) in the clinical setting. There were no venous thromboses or catheter occlusions during the catheter placements.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>This Formula could be acceptable in performing the bedside PICC placement in the real clinical settings.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/20584601251393792","type":"journal-article","created":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T18:21:48Z","timestamp":1761848508000},"update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":0,"title":["An acceptable predictive formula using pre-procedural chest radiograph for bedside insertion of peripherally inserted central venous catheter (PICC)"],"prefix":"10.1177","volume":"14","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4355-1553","authenticated-orcid":false,"given":"Takeo","family":"Kimoto","sequence":"first","affiliation":[{"name":"Osaka-fu Saiseikai Ibaraki Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daisuke","family":"Nakagawa","sequence":"additional","affiliation":[{"name":"Osaka-fu Saiseikai Ibaraki Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masaki","family":"Shimizu","sequence":"additional","affiliation":[{"name":"Osaka-fu Saiseikai Ibaraki Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shuji","family":"Tagami","sequence":"additional","affiliation":[{"name":"Osaka-fu Saiseikai Ibaraki Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2025,10,30]]},"reference":[{"key":"e_1_3_4_2_2","first-page":"99","article-title":"Peripherally inserted central catheters in critically ill patients-complications and its prevention: a review","volume":"6","author":"Duwadi S","year":"2018","unstructured":"Duwadi S, Zhao Q, Budal BS. Peripherally inserted central catheters in critically ill patients-complications and its prevention: a review. Int J Nurs Sci 2018; 6: 99\u2013105.","journal-title":"Int J Nurs Sci"},{"key":"e_1_3_4_3_2","doi-asserted-by":"publisher","DOI":"10.4065\/81.9.1159"},{"key":"e_1_3_4_4_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00520-004-0723-1"},{"key":"e_1_3_4_5_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-016-4666-y"},{"key":"e_1_3_4_6_2","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2343031823"},{"key":"e_1_3_4_7_2","doi-asserted-by":"publisher","DOI":"10.4266\/acc.2019.00731"},{"key":"e_1_3_4_8_2","doi-asserted-by":"publisher","DOI":"10.5301\/jva.5000431"},{"key":"e_1_3_4_9_2","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0171630"},{"key":"e_1_3_4_10_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00270-020-02551-0"},{"key":"e_1_3_4_11_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00270-017-1857-0"},{"key":"e_1_3_4_12_2","doi-asserted-by":"publisher","DOI":"10.1177\/11297298211001147"},{"key":"e_1_3_4_13_2","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0277526.eCollection2022"},{"key":"e_1_3_4_14_2","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0294598.eCollection2023"},{"key":"e_1_3_4_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1051-0443(97)70586-4"},{"key":"e_1_3_4_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.clnu.2009.03.015"},{"key":"e_1_3_4_17_2","doi-asserted-by":"publisher","DOI":"10.1053\/j.ajkd.2019.12.001"},{"key":"e_1_3_4_18_2","first-page":"S1","article-title":"Infusion nursing standards of practice","volume":"29","author":"Infusion Nurses Society","year":"2006","unstructured":"Infusion Nurses Society. Infusion nursing standards of practice. J Infusion Nurs 2006; 29: S1\u2013S92.","journal-title":"J Infusion Nurs"},{"key":"e_1_3_4_19_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/ael316"},{"key":"e_1_3_4_20_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.RVI.0000071097.76348.72"},{"key":"e_1_3_4_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1051-0443(07)61308-6"}],"container-title":["Acta Radiologica Open"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/20584601251393792","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/20584601251393792","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/20584601251393792","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T11:55:09Z","timestamp":1777377309000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/20584601251393792"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10]]},"references-count":20,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2025,10]]}},"alternative-id":["10.1177\/20584601251393792"],"URL":"https:\/\/doi.org\/10.1177\/20584601251393792","relation":{},"ISSN":["2058-4601","2058-4601"],"issn-type":[{"value":"2058-4601","type":"print"},{"value":"2058-4601","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,10]]},"article-number":"20584601251393792"}}