{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,25]],"date-time":"2026-06-25T05:02:23Z","timestamp":1782363743569,"version":"3.54.5"},"reference-count":35,"publisher":"SAGE Publications","license":[{"start":{"date-parts":[[2016,1,1]],"date-time":"2016-01-01T00:00:00Z","timestamp":1451606400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Trends in Hearing"],"published-print":{"date-parts":[[2016,1]]},"abstract":"<jats:p>For bilateral cochlear implant (CI) patients, electrodes that receive the same frequency allocation often stimulate locations in the left and right ear that do not yield the same perceived pitch, resulting in a pitch mismatch. This pitch mismatch may be related to degraded binaural abilities. Pitch mismatches have been found for some bilateral CI users and the goal of this study was to determine whether pitch mismatches are prevalent in bilateral CI patients, including those with extensive experience with bilateral CIs. To investigate this possibility, pitch matching was conducted with 16 bilateral CI patients. For 14 of the 16 participants, there was a significant difference between those electrodes in the left and right ear that yielded the same pitch and those that received the same frequency allocation in the participant\u2019s clinical map. The results suggest that pitch mismatches are prevalent with bilateral CI users. The results also indicated that pitch mismatches persist even with extended bilateral CI experience. Such mismatches may reduce the benefits patients receive from bilateral CIs.<\/jats:p>","DOI":"10.1177\/2331216516668302","type":"journal-article","created":{"date-parts":[[2016,9,18]],"date-time":"2016-09-18T20:07:36Z","timestamp":1474229256000},"update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":19,"title":["Clinically Paired Electrodes Are Often Not Perceived as Pitch Matched"],"prefix":"10.1177","volume":"20","author":[{"given":"Justin M.","family":"Aronoff","sequence":"first","affiliation":[{"name":"Department of Speech and Hearing Science, University of Illinois at Urbana-Champaign, IL, USA"},{"name":"Department of Otolaryngology\u2014Head and Neck Surgery, University of Illinois at Chicago, IL, USA"},{"name":"Communication and Neuroscience Division, House Ear Institute, Los Angeles, CA, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Monica","family":"Padilla","sequence":"additional","affiliation":[{"name":"Communication and Neuroscience Division, House Ear Institute, Los Angeles, CA, USA"},{"name":"Department of Otolaryngology, New York University School of Medicine, NY, USA"},{"name":"USC Tina and Rick Caruso Department of Otolaryngology, Head and Neck Surgery, University of Southern California, Los Angeles, CA, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Julia","family":"Stelmach","sequence":"additional","affiliation":[{"name":"Department of Speech and Hearing Science, University of Illinois at Urbana-Champaign, IL, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David M.","family":"Landsberger","sequence":"additional","affiliation":[{"name":"Communication and Neuroscience Division, House Ear Institute, Los Angeles, CA, USA"},{"name":"Department of Otolaryngology, New York University School of Medicine, NY, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2016,9,18]]},"reference":[{"key":"bibr1-2331216516668302","doi-asserted-by":"publisher","DOI":"10.1016\/j.heares.2014.12.005"},{"key":"bibr2-2331216516668302","doi-asserted-by":"publisher","DOI":"10.1097\/AUD.0000000000000249"},{"key":"bibr3-2331216516668302","doi-asserted-by":"publisher","DOI":"10.1097\/00129492-200501000-00007"},{"key":"bibr4-2331216516668302","doi-asserted-by":"publisher","DOI":"10.1097\/AUD.0b013e318167b870"},{"key":"bibr5-2331216516668302","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0b013e3181925025"},{"key":"bibr6-2331216516668302","first-page":"1","volume":"24","author":"Eddington D. K.","year":"1978","journal-title":"Transactions of the American Society for Artificial Internal Organs"},{"key":"bibr7-2331216516668302","doi-asserted-by":"publisher","DOI":"10.1177\/000348949110001004"},{"key":"bibr8-2331216516668302","doi-asserted-by":"publisher","DOI":"10.1097\/01.mao.0000281803.36574.bc"},{"key":"bibr9-2331216516668302","doi-asserted-by":"publisher","DOI":"10.1121\/1.2783130"},{"key":"bibr10-2331216516668302","doi-asserted-by":"publisher","DOI":"10.1121\/1.4792936"},{"key":"bibr11-2331216516668302","doi-asserted-by":"publisher","DOI":"10.1177\/2331216515617143"},{"key":"bibr12-2331216516668302","doi-asserted-by":"publisher","DOI":"10.1121\/1.4820889"},{"key":"bibr13-2331216516668302","doi-asserted-by":"publisher","DOI":"10.1097\/AUD.0b013e318257607b"},{"key":"bibr14-2331216516668302","doi-asserted-by":"publisher","DOI":"10.1121\/1.3372713"},{"key":"bibr15-2331216516668302","doi-asserted-by":"publisher","DOI":"10.1121\/1.3068457"},{"key":"bibr16-2331216516668302","doi-asserted-by":"publisher","DOI":"10.1121\/1.4862875"},{"key":"bibr17-2331216516668302","doi-asserted-by":"publisher","DOI":"10.1016\/j.heares.2009.04.007"},{"key":"bibr18-2331216516668302","doi-asserted-by":"publisher","DOI":"10.1097\/AUD.0000000000000163"},{"key":"bibr19-2331216516668302","doi-asserted-by":"publisher","DOI":"10.1097\/AUD.0000000000000250"},{"key":"bibr20-2331216516668302","doi-asserted-by":"crossref","unstructured":"Loizou, P. C., Hu, Y., Litovsky, R., Yu, G., Peters, R., Lake, J. & Roland, P. (2009). Speech recognition by bilateral cochlear implant users in a cocktail-party setting.\n                      The Journal of the Acoustical Society of America\n                      ,\n                      125\n                      (1), 372\u2013383.","DOI":"10.1121\/1.3036175"},{"key":"bibr21-2331216516668302","doi-asserted-by":"publisher","DOI":"10.1121\/1.1603765"},{"key":"bibr22-2331216516668302","unstructured":"Marsh, M. A., Xu, J., Blamey, P. J., Whitford, L. A., Xu, S. A., Silverman, J. M. & Clark, G. M. (1993). Radiologic evaluation of multichannel intracochlear implant insertion depth.\n                      The American Journal of Otology, 14\n                      (4), 386\u2013391."},{"key":"bibr23-2331216516668302","doi-asserted-by":"publisher","DOI":"10.1121\/1.3158821"},{"key":"bibr24-2331216516668302","doi-asserted-by":"publisher","DOI":"10.1097\/AUD.0000000000000114"},{"key":"bibr25-2331216516668302","doi-asserted-by":"publisher","DOI":"10.1007\/s10162-013-0434-8"},{"key":"bibr26-2331216516668302","doi-asserted-by":"publisher","DOI":"10.1097\/AUD.0b013e31820c81b0"},{"key":"bibr27-2331216516668302","doi-asserted-by":"publisher","DOI":"10.1016\/0378-5955(83)90077-1"},{"key":"bibr28-2331216516668302","doi-asserted-by":"publisher","DOI":"10.1016\/j.heares.2016.05.002"},{"key":"bibr29-2331216516668302","doi-asserted-by":"publisher","DOI":"10.3109\/00016489.2014.1002052"},{"key":"bibr30-2331216516668302","doi-asserted-by":"crossref","unstructured":"Tong, Y. C., Black, R. C., Clark, G. M., Forster, I. C., Millar, J. B., O Loughlin, B. J. & Patrick, J. F. (1979). A preliminary report on a multiple-channel cochlear implant operation.\n                      The Journal of Laryngology and Otology, 93\n                      (7), 679\u2013695.","DOI":"10.1017\/S0022215100087545"},{"key":"bibr31-2331216516668302","doi-asserted-by":"publisher","DOI":"10.1159\/000078393"},{"key":"bibr32-2331216516668302","doi-asserted-by":"crossref","unstructured":"Vermeire, K., Landsberger, D. M., Van de Heyning, P. H., Voormolen, M., Kleine Punte, A., Schatzer, R. & Zierhofer, C. (2015). Frequency-place map for electrical stimulation in cochlear implants: Change over time. hearing Research,\n                      326\n                      , 8\u201314.","DOI":"10.1016\/j.heares.2015.03.011"},{"key":"bibr33-2331216516668302","doi-asserted-by":"publisher","DOI":"10.1121\/1.3606460"},{"key":"bibr34-2331216516668302","doi-asserted-by":"publisher","DOI":"10.1097\/AUD.0b013e31826709e8"},{"key":"bibr35-2331216516668302","doi-asserted-by":"publisher","DOI":"10.1016\/S0378-5955(02)00644-5"}],"container-title":["Trends in Hearing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/2331216516668302","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/2331216516668302","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/2331216516668302","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T00:41:52Z","timestamp":1777596112000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/2331216516668302"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,1]]},"references-count":35,"alternative-id":["10.1177\/2331216516668302"],"URL":"https:\/\/doi.org\/10.1177\/2331216516668302","relation":{},"ISSN":["2331-2165","2331-2165"],"issn-type":[{"value":"2331-2165","type":"print"},{"value":"2331-2165","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,1]]},"article-number":"2331216516668302"}}