{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,14]],"date-time":"2026-07-14T15:10:33Z","timestamp":1784041833202,"version":"3.55.0"},"reference-count":24,"publisher":"SAGE Publications","license":[{"start":{"date-parts":[[2019,1,1]],"date-time":"2019-01-01T00:00:00Z","timestamp":1546300800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"funder":[{"DOI":"10.13039\/501100000265","name":"Medical Research Council","doi-asserted-by":"publisher","award":["MR\/L003589\/1"],"award-info":[{"award-number":["MR\/L003589\/1"]}],"id":[{"id":"10.13039\/501100000265","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100014653","name":"NIHR Manchester Biomedical Research Centre","doi-asserted-by":"crossref","id":[{"id":"10.13039\/100014653","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Trends in Hearing"],"published-print":{"date-parts":[[2019,1]]},"abstract":"<jats:p>The acoustic reflex (AR), a longstanding component of the audiological test battery, has received renewed attention in the context of noise-induced cochlear synaptopathy\u2014the destruction of synapses between inner hair cells and auditory nerve fibers. Noninvasive proxy measures of synaptopathy are widely sought, and AR thresholds (ARTs) correlate closely with synaptic survival in rodents. However, measurement in humans at high stimulus frequencies\u2014likely important when testing for noise-induced pathology\u2014can be challenging; reflexes at 4\u2009kHz are frequently absent or occur only at high stimulus levels, even in young people with clinically normal audiograms. This phenomenon may partly reflect differences across stimulus frequency in the temporal characteristics of the response; later onset of the response, earlier onset of adaptation, and higher rate of adaptation have been observed at 4\u2009kHz than at 1\u2009kHz. One temporal aspect of the response that has received little attention is the interstimulus interval (ISI); inadequate duration of ISI might lead to incomplete recovery of the response between successive presentations and consequent response fatigue. This research aimed to test for effects of ISI on ARTs in normally hearing young humans, measured at 1 and 4\u2009kHz. Contrary to our hypotheses, increasing ISIs from 2.5 to 8.5\u2009s did not reduce ART level, nor raise ART reliability. Results confirm that clinically measured ARTs\u2014including those at 4\u2009kHz\u2014can exhibit excellent reliability and that relatively short (2.5\u2009s) ISIs are adequate for the measurement of sensitive and reliable ARTs.<\/jats:p>","DOI":"10.1177\/2331216519874165","type":"journal-article","created":{"date-parts":[[2019,9,13]],"date-time":"2019-09-13T06:01:37Z","timestamp":1568354497000},"update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":3,"title":["No Effect of Interstimulus Interval on Acoustic Reflex Thresholds"],"prefix":"10.1177","volume":"23","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4981-6663","authenticated-orcid":false,"given":"Hannah","family":"Guest","sequence":"first","affiliation":[{"name":"Manchester Centre for Audiology and Deafness, Manchester Academic Health Science Centre, University of Manchester, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kevin J.","family":"Munro","sequence":"additional","affiliation":[{"name":"Manchester Centre for Audiology and Deafness, Manchester Academic Health Science Centre, University of Manchester, UK"},{"name":"Manchester University NHS Foundation Trust, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3635-863X","authenticated-orcid":false,"given":"Samuel","family":"Couth","sequence":"additional","affiliation":[{"name":"Manchester Centre for Audiology and Deafness, Manchester Academic Health Science Centre, University of Manchester, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rebecca E.","family":"Millman","sequence":"additional","affiliation":[{"name":"Manchester Centre for Audiology and Deafness, Manchester Academic Health Science Centre, University of Manchester, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7255-6708","authenticated-orcid":false,"given":"Garreth","family":"Prendergast","sequence":"additional","affiliation":[{"name":"Manchester Centre for Audiology and Deafness, Manchester Academic Health Science Centre, University of Manchester, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karolina","family":"Kluk","sequence":"additional","affiliation":[{"name":"Manchester Centre for Audiology and Deafness, Manchester Academic Health Science Centre, University of Manchester, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carlyn","family":"Murray","sequence":"additional","affiliation":[{"name":"Manchester Centre for Audiology and Deafness, Manchester Academic Health Science Centre, University of Manchester, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chris","family":"Plack","sequence":"additional","affiliation":[{"name":"Manchester Centre for Audiology and Deafness, Manchester Academic Health Science Centre, University of Manchester, UK"},{"name":"Department of Psychology, Lancaster University, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2019,9,13]]},"reference":[{"key":"bibr1-2331216519874165","doi-asserted-by":"publisher","DOI":"10.3109\/00016487909126445"},{"key":"bibr112-2331216519874165","unstructured":"British Society of Audiology. (2011).\n                      Pure-tone air-conduction and bone-conduction threshold audiometry with and without masking.\n                      British Society of Audiology, Reading, UK."},{"key":"bibr113-2331216519874165","unstructured":"British Standards Institution. (2005).\n                      Electroacoustics. Audiometric equipment.\n                      Instruments for the measurement of aural acoustic impedance\/admittance\n                      (BS EN 60645-5)."},{"key":"bibr114-2331216519874165","unstructured":"British Standards Institution. (2017).\n                      Electroacoustics. Audiometric equipment.\n                      Equipment for pure-tone and speech audiometry\n                      (BS EN 60645-1)."},{"key":"bibr2-2331216519874165","doi-asserted-by":"publisher","DOI":"10.1046\/j.1365-2273.2000.00368.x"},{"key":"bibr116-2331216519874165","doi-asserted-by":"crossref","unstructured":"Feeney, M.P., Keefe, D.H., Hunter, L.L., Fitzpatrick, D.F., Garinis, A.C., Putterman, D.B., McMillan, G.P. (2017) Normative wideband reflectance, equivalent admittance at the tympanic membrane, and acoustic stapedius reflex threshold in adults.\n                      Ear Hear\n                      38: e142\u2013e160.","DOI":"10.1097\/AUD.0000000000000399"},{"key":"bibr3-2331216519874165","doi-asserted-by":"publisher","DOI":"10.1080\/14992027.2016.1257164"},{"key":"bibr4-2331216519874165","doi-asserted-by":"publisher","DOI":"10.1097\/00003446-198409000-00004"},{"key":"bibr5-2331216519874165","unstructured":"Gelfand, S. A. (2009). The acoustic reflex. In J. Katz, L. Medwetsky, R. Burkard, & L. Hood (Eds.),\n                      Handbook of clinical audiology\n                      (6th ed.) (pp. 189\u2013221). Baltimore, MD: Lippincott Williams & Wilkins."},{"key":"bibr6-2331216519874165","doi-asserted-by":"publisher","DOI":"10.1016\/j.neuroscience.2018.12.019"},{"key":"bibr7-2331216519874165","doi-asserted-by":"publisher","DOI":"10.1016\/j.heares.2019.01.018"},{"key":"bibr8-2331216519874165","author":"Hunter L.","year":"2013","journal-title":"Audiology Online"},{"key":"bibr9-2331216519874165","doi-asserted-by":"publisher","DOI":"10.1080\/00206097709071832"},{"key":"bibr10-2331216519874165","doi-asserted-by":"publisher","DOI":"10.1097\/00003446-198712000-00006"},{"key":"bibr11-2331216519874165","doi-asserted-by":"publisher","DOI":"10.3109\/01050398609045951"},{"key":"bibr12-2331216519874165","volume-title":"Metronome M1","author":"JSplash Apps","year":"2018"},{"key":"bibr13-2331216519874165","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcm.2016.02.012"},{"key":"bibr14-2331216519874165","doi-asserted-by":"publisher","DOI":"10.1016\/j.heares.2017.01.003"},{"key":"bibr15-2331216519874165","doi-asserted-by":"publisher","DOI":"10.1590\/S0104-56872008000100009"},{"key":"bibr16-2331216519874165","volume-title":"R: A language and environment for statistical computing","author":"R Core Team","year":"2015"},{"key":"bibr17-2331216519874165","doi-asserted-by":"publisher","DOI":"10.1037\/0033-2909.86.2.420"},{"key":"bibr18-2331216519874165","doi-asserted-by":"publisher","DOI":"10.1016\/j.heares.2018.03.012"},{"key":"bibr19-2331216519874165","doi-asserted-by":"publisher","DOI":"10.1121\/1.382043"},{"key":"bibr20-2331216519874165","doi-asserted-by":"publisher","DOI":"10.1523\/ENEURO.0363-17.2017"}],"container-title":["Trends in Hearing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/2331216519874165","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/2331216519874165","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/2331216519874165","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T00:44:49Z","timestamp":1777596289000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/2331216519874165"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,1]]},"references-count":24,"alternative-id":["10.1177\/2331216519874165"],"URL":"https:\/\/doi.org\/10.1177\/2331216519874165","relation":{},"ISSN":["2331-2165","2331-2165"],"issn-type":[{"value":"2331-2165","type":"print"},{"value":"2331-2165","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,1]]},"article-number":"2331216519874165"}}