{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,3]],"date-time":"2026-08-03T22:40:36Z","timestamp":1785796836657,"version":"3.56.0"},"reference-count":30,"publisher":"SAGE Publications","license":[{"start":{"date-parts":[[2024,1,1]],"date-time":"2024-01-01T00:00:00Z","timestamp":1704067200000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100021851","name":"William Demant Fonden","doi-asserted-by":"publisher","award":["90561"],"award-info":[{"award-number":["90561"]}],"id":[{"id":"10.13039\/501100021851","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Trends in Hearing"],"published-print":{"date-parts":[[2024,1]]},"abstract":"<jats:p>This study aimed to assess the validity of a high-frequency audiometry tool based on Bayesian learning to provide a reliable, repeatable, automatic, and fast test to clinics. The study involved 85 people (138 ears) who had their high-frequency thresholds measured with three tests: standard audiometry (SA), alternative forced choice (AFC)-based algorithm, and Bayesian active (BA) learning-based algorithm. The results showed median differences within \u00b15 dB up to 10 kHz when comparing the BA with the other two tests, and median differences within \u00b110 dB at higher frequencies. The variability increased from lower to higher frequencies. The BA showed lower thresholds compared to the SA at the majority of the frequencies. The results of the different tests were consistent across groups (age, hearing loss, and tinnitus). The data for the BA showed high test\u2013retest reliability (&gt;90%). The time required for the BA was shorter than for the AFC (4\u2005min vs. 13\u2005min). The data suggest that the BA test for high-frequency audiometry could be a good candidate for clinical screening. It would add reliable and significant information without adding too much time to the visit.<\/jats:p>","DOI":"10.1177\/23312165231225545","type":"journal-article","created":{"date-parts":[[2024,1,9]],"date-time":"2024-01-09T02:17:23Z","timestamp":1704766643000},"update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":3,"title":["Evaluation of a Fast Method to Measure High-Frequency Audiometry Based on Bayesian Learning"],"prefix":"10.1177","volume":"28","author":[{"given":"Chiara","family":"Casolani","sequence":"first","affiliation":[{"name":"Auditory Physics Group, Hearing Systems section, Department of Health Technology, Technical University of Denmark, Lyngby, Denmark"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ali","family":"Borhan-Azad","sequence":"additional","affiliation":[{"name":"Auditory Physics Group, Hearing Systems section, Department of Health Technology, Technical University of Denmark, Lyngby, Denmark"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rikke Skovh\u00f8j","family":"S\u00f8rensen","sequence":"additional","affiliation":[{"name":"Auditory Physics Group, Hearing Systems section, Department of Health Technology, Technical University of Denmark, Lyngby, Denmark"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Josef","family":"Schlittenlacher","sequence":"additional","affiliation":[{"name":"Speech Hearing and Phonetic Sciences, University College, London, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8062-0837","authenticated-orcid":false,"given":"Bastian","family":"Epp","sequence":"additional","affiliation":[{"name":"Auditory Physics Group, Hearing Systems section, Department of Health Technology, Technical University of Denmark, Lyngby, Denmark"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2024,1,8]]},"reference":[{"key":"bibr1-23312165231225545","doi-asserted-by":"publisher","DOI":"10.1093\/occmed\/51.4.245"},{"key":"bibr2-23312165231225545","doi-asserted-by":"publisher","DOI":"10.1016\/j.bjorl.2015.08.016"},{"key":"bibr3-23312165231225545","unstructured":"ASHA (2005). Guidelines for manual pure-tone threshold audiometry. https:\/\/www.asha.org\/policy."},{"key":"bibr4-23312165231225545","doi-asserted-by":"publisher","DOI":"10.1121\/1.4840775"},{"key":"bibr5-23312165231225545","doi-asserted-by":"publisher","DOI":"10.1186\/s40463-019-0385-0"},{"key":"bibr6-23312165231225545","doi-asserted-by":"publisher","DOI":"10.1097\/AUD.0b013e318228a77d"},{"key":"bibr7-23312165231225545","volume-title":"Audiology: The fundamentals","author":"Bess F. H.","year":"2008","edition":"4"},{"key":"bibr8-23312165231225545","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0b013e318263d598"},{"key":"bibr9-23312165231225545","unstructured":"Cardillo G. (2023). Wilcoxon. https:\/\/github.com\/dnafinder\/wilcoxon"},{"key":"bibr10-23312165231225545","first-page":"421","volume":"7","author":"Casolani C.","year":"2020","journal-title":"Proceedings of the International Symposium on Auditory and Audiological Research: Auditory Learning in Biological and Artificial Systems"},{"key":"bibr11-23312165231225545","doi-asserted-by":"publisher","DOI":"10.1177\/014556131109000506"},{"key":"bibr12-23312165231225545","doi-asserted-by":"publisher","DOI":"10.3389\/fdgth.2021.723348"},{"key":"bibr13-23312165231225545","doi-asserted-by":"publisher","DOI":"10.1044\/jshd.4003.351"},{"key":"bibr14-23312165231225545","first-page":"1326","volume-title":"Proceedings of the international conference on acoustics AIA-DAGA 2013, Merano, Italy","author":"Ewert S.","year":"2013"},{"key":"bibr15-23312165231225545","doi-asserted-by":"publisher","DOI":"10.1097\/00003446-200104000-00009"},{"key":"bibr16-23312165231225545","doi-asserted-by":"publisher","DOI":"10.1152\/jn.00164.2013"},{"key":"bibr17-23312165231225545","doi-asserted-by":"publisher","DOI":"10.1016\/0021-9924(86)90012-2"},{"key":"bibr18-23312165231225545","doi-asserted-by":"publisher","DOI":"10.3813\/AAA.919218"},{"key":"bibr19-23312165231225545","doi-asserted-by":"publisher","DOI":"10.1016\/j.heares.2016.12.008"},{"key":"bibr20-23312165231225545","doi-asserted-by":"publisher","DOI":"10.3758\/BF03194543"},{"key":"bibr21-23312165231225545","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0162726"},{"key":"bibr22-23312165231225545","volume-title":"9.11.0.1769968 (r2021b)","author":"MATLAB","year":"2021"},{"key":"bibr23-23312165231225545","doi-asserted-by":"publisher","DOI":"10.4103\/1463-1741.90295"},{"key":"bibr24-23312165231225545","volume-title":"Neuroscience","author":"Purves D.","year":"2001","edition":"2"},{"key":"bibr25-23312165231225545","first-page":"3011","volume":"11","author":"Rasmussen C. E.","year":"2010","journal-title":"The Journal of Machine Learning Research"},{"key":"bibr26-23312165231225545","doi-asserted-by":"publisher","DOI":"10.1121\/1.5047436"},{"key":"bibr27-23312165231225545","doi-asserted-by":"publisher","DOI":"10.1097\/01.AUD.0000120361.87401.C8"},{"key":"bibr28-23312165231225545","doi-asserted-by":"publisher","DOI":"10.1097\/AUD.0000000000000186"},{"key":"bibr29-23312165231225545","doi-asserted-by":"publisher","DOI":"10.1155\/2015\/302515"},{"key":"bibr30-23312165231225545","doi-asserted-by":"publisher","DOI":"10.1186\/s40463-021-00534-w"}],"container-title":["Trends in Hearing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/23312165231225545","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/23312165231225545","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/23312165231225545","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T00:48:42Z","timestamp":1777596522000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/23312165231225545"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1]]},"references-count":30,"alternative-id":["10.1177\/23312165231225545"],"URL":"https:\/\/doi.org\/10.1177\/23312165231225545","relation":{},"ISSN":["2331-2165","2331-2165"],"issn-type":[{"value":"2331-2165","type":"print"},{"value":"2331-2165","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,1]]},"article-number":"23312165231225545"}}