{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,13]],"date-time":"2026-11-13T09:09:02Z","timestamp":1794560942607,"version":"4.9.1"},"reference-count":34,"publisher":"SAGE Publications","license":[{"start":{"date-parts":[[2023,1,1]],"date-time":"2023-01-01T00:00:00Z","timestamp":1672531200000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"funder":[{"DOI":"10.13039\/100007489","name":"Bausch and Lomb","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100007489","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Ophthalmol Eye Dis"],"published-print":{"date-parts":[[2023,1]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Extended depth-of-focus (EDOF) intraocular lenses (IOLs) provide a continuous range of uncorrected vision at different distances.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Objective:<\/jats:title>\n                    <jats:p>To assess visual acuity, refractive outcomes, and patient satisfaction after cataract surgery using the LuxSmart EDOF IOL (Bausch+Lomb).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Design:<\/jats:title>\n                    <jats:p>A two-center, prospective observational clinical study.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>This study includes patients who have undergone bilateral phacoemulsification with bilateral implantation of the LuxSmart EDOF IOL, with the aim of achieving emmetropia. Visual acuity (VA) and subjective refraction were obtained in all patients preoperatively and at 1\u2009week, 1\u2009month, 3\u2009months, and 6\u2009months postoperatively. Subjective measures were obtained using the Catquest-9SF questionnaire and the Patient-Reported Spectacle Independence Questionnaire (PRSIQ). Contrast sensitivity and a glare assessment were undertaken postoperatively. Safety outcomes were additionally assessed.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>Sixty eyes from thirty patients were recruited for this study. The mean spherical equivalent was 1.04\u2009\u00b1\u20091.67\u2009D preoperatively and \u22120.30\u2009\u00b1\u20090.46\u2009D at 6\u2009months. Monocular uncorrected distance VA was 0.57\u2009\u00b1\u20090.32 (logMAR) preoperatively and 0.09\u2009\u00b1\u20090.12 (logMAR) at 6\u2009months. Mean 6-month monocular uncorrected VA was 0.11\u2009\u00b1\u20090.13, 0.12\u2009\u00b1\u20090.15, and 0.31\u2009\u00b1\u20090.15 (logMAR) at 80, 66, and 40\u2009cm, respectively. More than 90% of patients were either fairly or very satisfied with their vision. There was one case of suspected vitreomacular traction postoperatively.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>The LuxSmart EDOF IOL offers good refractive, VA, and safety outcomes. The single elongated focal point designed to enhance the DOF shows good results for VA and patient satisfaction.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/25158414231200108","type":"journal-article","created":{"date-parts":[[2023,10,3]],"date-time":"2023-10-03T04:43:22Z","timestamp":1696308202000},"update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":7,"title":["Evaluation of extended depth-of-focus hydrophobic intraocular lens with an optic concept based on combination of high-order aberrations"],"prefix":"10.1177","volume":"15","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3213-640X","authenticated-orcid":false,"given":"Pavel","family":"Stodulka","sequence":"first","affiliation":[{"name":"Gemini Eye Clinic, U Gemini 360, Prague, Zlin 760 01, Czech Republic; 3rd Faculty of Medicine at Charles University, Prague, Czech Republic"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zuzana","family":"Pracharova","sequence":"additional","affiliation":[{"name":"Gemini Eye Clinic, Vyskov, Czech Republic"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2023,10,3]]},"reference":[{"key":"bibr1-25158414231200108","volume":"12","author":"de Silva SR","year":"2016","journal-title":"Cochrane Database Syst Rev"},{"key":"bibr2-25158414231200108","doi-asserted-by":"publisher","DOI":"10.1097\/APO.0000000000000296"},{"key":"bibr3-25158414231200108","doi-asserted-by":"publisher","DOI":"10.1097\/APO.0000000000000590"},{"key":"bibr4-25158414231200108","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2010.07.022"},{"key":"bibr5-25158414231200108","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20220926-01"},{"key":"bibr6-25158414231200108","doi-asserted-by":"publisher","DOI":"10.1016\/j.visres.2011.10.003"},{"key":"bibr7-25158414231200108","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2008.11.038"},{"key":"bibr8-25158414231200108","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2017.03.018"},{"key":"bibr9-25158414231200108","unstructured":"Kramer R, Schyns M, Wessels H, et al. Halo & Glare simulator, https:\/\/mediawebtool.com\/counselor\/vs.php?cnr=00VS-DEMO&mod=hal (accessed 4 July 2022)."},{"key":"bibr10-25158414231200108","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-021-05362-2"},{"key":"bibr11-25158414231200108","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S344379"},{"key":"bibr12-25158414231200108","doi-asserted-by":"publisher","DOI":"10.1038\/sj.eye.6702446"},{"key":"bibr13-25158414231200108","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.2009.163485"},{"key":"bibr14-25158414231200108","doi-asserted-by":"publisher","DOI":"10.1007\/s10792-016-0398-x"},{"key":"bibr15-25158414231200108","doi-asserted-by":"publisher","DOI":"10.1111\/j.1442-9071.2007.01452.x"},{"key":"bibr16-25158414231200108","doi-asserted-by":"publisher","DOI":"10.5301\/ejo.5000315"},{"key":"bibr17-25158414231200108","doi-asserted-by":"publisher","DOI":"10.1186\/1471-2415-15-5"},{"key":"bibr18-25158414231200108","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-019-1204-0"},{"key":"bibr19-25158414231200108","doi-asserted-by":"publisher","DOI":"10.1080\/02713683.2022.2074046"},{"key":"bibr20-25158414231200108","volume-title":"American National Standard for Ophthalmics \u2013 Extended Depth of Focus Intraocular Lenses","author":"American National Standards Institute"},{"key":"bibr21-25158414231200108","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20221130-04"},{"key":"bibr22-25158414231200108","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0277687"},{"key":"bibr23-25158414231200108","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-021-05245-6"},{"key":"bibr24-25158414231200108","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-021-91654-w"},{"key":"bibr25-25158414231200108","first-page":"317","volume":"66","author":"Nicula CA","year":"2022","journal-title":"Rom J Ophthalmol"},{"key":"bibr26-25158414231200108","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000971"},{"key":"bibr27-25158414231200108","doi-asserted-by":"publisher","DOI":"10.1155\/2022\/4119698"},{"key":"bibr28-25158414231200108","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S405267"},{"key":"bibr29-25158414231200108","first-page":"3357","volume":"35","author":"Pomerance GN","year":"1994","journal-title":"Investig Ophthalmol Vis Sci"},{"key":"bibr30-25158414231200108","doi-asserted-by":"publisher","DOI":"10.5301\/EJO.2010.521"},{"key":"bibr31-25158414231200108","doi-asserted-by":"publisher","DOI":"10.4236\/ojoph.2021.113017"},{"key":"bibr32-25158414231200108","unstructured":"Beaver-Visitec International Inc. PMCF Study on EDOF (Isopure) vs Monofocal (Micropure) IOL (PHY2001), https:\/\/www.centerwatch.com\/clinical-trials\/listings\/237411\/pmcf-study-on-edof-isopure-vs-monofocal-micropure-iol\/ (2022, accessed 18 January 2023)."},{"key":"bibr33-25158414231200108","doi-asserted-by":"publisher","DOI":"10.1097\/ICU.0b013e3283414284"},{"key":"bibr34-25158414231200108","doi-asserted-by":"publisher","DOI":"10.1016\/S2214-109X(17)30393-5"}],"container-title":["Therapeutic Advances in Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/25158414231200108","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/25158414231200108","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/25158414231200108","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T00:40:26Z","timestamp":1777596026000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/25158414231200108"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,1]]},"references-count":34,"alternative-id":["10.1177\/25158414231200108"],"URL":"https:\/\/doi.org\/10.1177\/25158414231200108","relation":{},"ISSN":["2515-8414","2515-8414"],"issn-type":[{"value":"2515-8414","type":"print"},{"value":"2515-8414","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,1]]},"article-number":"25158414231200108"}}