{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,6]],"date-time":"2026-03-06T00:31:01Z","timestamp":1772757061682,"version":"3.50.1"},"reference-count":24,"publisher":"SAGE Publications","issue":"5","license":[{"start":{"date-parts":[[2005,10,1]],"date-time":"2005-10-01T00:00:00Z","timestamp":1128124800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Indoor and Built Environment"],"published-print":{"date-parts":[[2005,10]]},"abstract":"<jats:p> The rate at which particles deposit and re-suspend from indoor surfaces is an essential parameter in determining human exposure to aerosol particles. In this study, we investigate experimentally particle deposition and forced re-suspension in a cubical enclosure for three particle sizes (0.7, 1.5 and 4 m). <\/jats:p><jats:p> For particle deposition, the results are presented in terms of particle deposition velocity. It was observed that the particle deposition velocity is particularly significant for the floor surface. Deposition on vertical and ceiling surfaces becomes important only when these surfaces are electrically charged. Air humidity did not influence the particle deposition apart from when it was close to saturation. <\/jats:p><jats:p> Re-suspension of particles from the floor surface due to household activities was also studied. It was observed that small particles are more difficult to detach from the floor than bigger ones. Besides, there is a pressure above which re-suspension is very likely to occur (minimum re-suspension pressure). This minimum pressure is dependent on the particle size. <\/jats:p>","DOI":"10.1177\/1420326x05057948","type":"journal-article","created":{"date-parts":[[2005,9,23]],"date-time":"2005-09-23T12:08:04Z","timestamp":1127477284000},"page":"391-396","source":"Crossref","is-referenced-by-count":19,"title":["Indoor Deposition and Forced Re-suspension of Respirable Particles"],"prefix":"10.1177","volume":"14","author":[{"given":"Ant\u00f3nio F.","family":"Miguel","sequence":"first","affiliation":[{"name":"\u2026vora Geophysics Centre, \u2026vora, Portugal;                         Department of Physics, University of \u2026vora"}]},{"given":"Murat","family":"Aydin","sequence":"additional","affiliation":[{"name":"\u2026vora Geophysics Centre, \u2026vora, Portugal;                         Department of Mechanical Engineering, Istanbul Technical University, Turkey"}]},{"given":"A. Heitor","family":"Reis","sequence":"additional","affiliation":[{"name":"\u2026vora Geophysics Centre, \u2026vora, Portugal;                         Department of Physics, University of \u2026vora"}]}],"member":"179","published-online":{"date-parts":[[2005,10,1]]},"reference":[{"key":"atypb1","volume-title":"Particles in Our Air: Concentrations and Health Effects","author":"Wilson R","year":"1996"},{"key":"atypb2","first-page":"981","volume":"36","author":"Kosonen R","year":"2004","journal-title":"The Effect of Perceived Indoor Air Quality on Productivity Loss: Energy Buildings"},{"key":"atypb3","first-page":"26","volume":"10","author":"Seltzer JM","year":"1995","journal-title":"Effects of the Indoor Environment on Health: Occup Med"},{"key":"atypb4","doi-asserted-by":"publisher","DOI":"10.1007\/978-1-4757-4221-3"},{"key":"atypb5","volume-title":"Particle Size-Selective Aerosol Sampling in the Workplace, Some Practical Application Issues","author":"American Industrial Hygiene Association (AIHA)","year":"1996"},{"key":"atypb6","unstructured":"European Committee for Standardisation (CEN)                 : Workplace atmospheres \u2013 size fraction definitions from                     measurements of airborne particles.                      European Standard EN 481-481, 1993."},{"key":"atypb7","first-page":"1487","volume":"29","author":"Thatcher TL","year":"1995","journal-title":"Deposition, Resuspension, and Penetration of Particles within a Residence: Atmos Environ"},{"key":"atypb8","first-page":"205","volume":"151","author":"Li C S","year":"1994","journal-title":"Relationships of Indoor\/Outdoor Inhalable and Respirable Particles in Domestic Environments: Sci Total Environ"},{"key":"atypb9","first-page":"211","volume":"12","author":"Lai ACK","year":"2002","journal-title":"Particle Deposition Indoors \u2013 A Review: Indoor Air"},{"key":"atypb10","first-page":"847","volume":"37","author":"Thatcher TL","year":"2003","journal-title":"A Concentration Rebound Method for Measuring Particle Penetration and Deposition in the Indoor Environment: Aerosol Sci Technol"},{"key":"atypb11","first-page":"443","volume":"13","author":"Zhao B","year":"2004","journal-title":"Numerical Study of Particle Deposition in Two Differently Ventilated Rooms: Indoor Built Environ"},{"key":"atypb12","first-page":"S667","volume":"34","author":"Miguel AF","year":"2003","journal-title":"Particle Deposition onto a Flat Plate with Various Slopes: J Aerosol Sci"},{"key":"atypb13","first-page":"11","volume":"11","author":"Raunemaa T","year":"1989","journal-title":"Indoor Aerosol Model: Transport Indoors and Deposition of Fine and Coarse Particles: Aerosol Sci Technol"},{"key":"atypb14","first-page":"939","volume":"25","author":"Kamens R","year":"1991","journal-title":"A Study to Characterise Indoor Particle in Three Non-Smoking Homes: Atmos Environ"},{"key":"atypb15","first-page":"227","volume":"6","author":"Clayton CA","year":"1993","journal-title":"Particle Total Exposure Methodology (PTEAM) Study: Distribution of Aerosol and Elemental Concentrations in Personal, Indoor, and Outdoor Air Samples in a Southern California community: J Expo Anal Envir Epidemi"},{"key":"atypb16","first-page":"143","volume":"13","author":"Kousaka Y","year":"1980","journal-title":"Reentrainment of Small Aggregate Particles from a Plane Surface by Air Stream: J Chem Engng Jpn"},{"key":"atypb17","volume-title":"Proc Roomvent \u201998","author":"Lengweiler P","year":"1998"},{"key":"atypb18","unstructured":"Wedberg WC                 : The Influence of Static Electricity on Aerosol Deposition in Indoor                     Environments, Proc 2nd Intl Aerosol Conf,                      Pergamon Press, Oxford                 , 1986, pp. 793\u2013795."},{"key":"atypb19","first-page":"246","volume":"19","author":"Nielsen NF","year":"1998","journal-title":"Particle Deposition onto a Human Head: Influence of Electrostatic and Wind Fields: Bioelectromagnetics"},{"key":"atypb20","first-page":"113","volume":"18","author":"Vincent JH","year":"1986","journal-title":"Industrial Hygiene Implications of Static Electrification of Workplace Aerosols: J Electrostatics"},{"key":"atypb21","first-page":"249","volume":"116","author":"Miguel AF","year":"2004","journal-title":"Aerosol Particle Deposition and Distribution in Bifurcating Ventilation Ducts: J Hazardous Mat"},{"key":"atypb22","first-page":"783","volume":"34","author":"Miguel AF","year":"2003","journal-title":"Effect of Air Humidity on the Evolution of Permeability and Performance of a Fibrous Filter during Loading with Hygroscopic and Non-hygroscopic Particles: J Aerosol Sci"},{"key":"atypb23","first-page":"25","volume":"125","author":"Pesva P","year":"1999","journal-title":"Dry Deposition of Particles to Building Surfaces and Soiling: Sci Total Environ"},{"key":"atypb24","volume-title":"Particle Loading and Kinetics of Filtration in Fibrous Filters","author":"Lehmann MJ","year":"2002"}],"container-title":["Indoor and Built Environment"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/1420326X05057948","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/1420326X05057948","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,2]],"date-time":"2025-03-02T20:37:50Z","timestamp":1740947870000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/1420326X05057948"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2005,10]]},"references-count":24,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2005,10]]}},"alternative-id":["10.1177\/1420326X05057948"],"URL":"https:\/\/doi.org\/10.1177\/1420326x05057948","relation":{},"ISSN":["1420-326X","1423-0070"],"issn-type":[{"value":"1420-326X","type":"print"},{"value":"1423-0070","type":"electronic"}],"subject":[],"published":{"date-parts":[[2005,10]]}}}