{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,3]],"date-time":"2026-05-03T14:12:42Z","timestamp":1777817562670,"version":"3.51.4"},"reference-count":11,"publisher":"SAGE Publications","issue":"1","license":[{"start":{"date-parts":[[2011,5,24]],"date-time":"2011-05-24T00:00:00Z","timestamp":1306195200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Journal of Building Physics"],"published-print":{"date-parts":[[2011,7]]},"abstract":"<jats:p>In this article, the passive thermal performance of a light steel residential building is studied. A numerical model is implemented and is experimentally validated. The analysis is focussed on the Csb climatic region. Subsequently, this calibrated model is used to assess the importance of several parameters (ventilation, thermal insulation, overhangs shading, windows shade devices, and windows glazing) in the summer and winter thermal performance of this building. Subsequently, based on the cooling and heating seasons thermal performance, an optimum building envelope and operational solution is specified for average Csb climate conditions. Finally, design guidance is provided for the specification of building components and the operation of the building for the range of climatic conditions within the Csb climatic region.<\/jats:p>","DOI":"10.1177\/1744259111403440","type":"journal-article","created":{"date-parts":[[2011,5,24]],"date-time":"2011-05-24T20:49:36Z","timestamp":1306270176000},"page":"7-53","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":17,"title":["Parametric analysis of the thermal performance of light steel residential buildings in Csb climatic regions"],"prefix":"10.1177","volume":"35","author":[{"given":"P","family":"Santos","sequence":"first","affiliation":[{"name":"CICC, Civil Engineering Department, University of Coimbra, Coimbra, Portugal,"}]},{"given":"L","family":"Sim\u00f5es da Silva","sequence":"additional","affiliation":[{"name":"ISISE, Civil Engineering Department, University of Coimbra, Coimbra, Portugal"}]},{"given":"H","family":"Gerv\u00e1sio","sequence":"additional","affiliation":[{"name":"ISISE, Civil Engineering Department, University of Coimbra, Coimbra, Portugal"}]},{"given":"A","family":"Gameiro Lopes","sequence":"additional","affiliation":[{"name":"ADAI, Mechanical Engineering Department, University of Coimbra, Coimbra, Portugal"}]}],"member":"179","published-online":{"date-parts":[[2011,5,24]]},"reference":[{"key":"atypb1","doi-asserted-by":"publisher","DOI":"10.1016\/j.buildenv.2006.10.027"},{"key":"atypb2","volume-title":"DesignBuilder software version 1.6.9.003","author":"DesignBuilder","year":"2008"},{"key":"atypb3","volume-title":"United States Department of Energy - Energy Efficiency and Renewable Energy","author":"Doe-Eere","year":"2010"},{"key":"atypb4","volume-title":"EnergyPlus software version 2.2.0.025","author":"EnergyPlus","year":"2008"},{"key":"atypb5","author":"European Light Steel Construction Association (LSK)","year":"2005","journal-title":"Arcelor House"},{"key":"atypb6","doi-asserted-by":"publisher","DOI":"10.1016\/j.renene.2008.01.001"},{"issue":"2","key":"atypb7","first-page":"742","volume":"6","author":"Gerv\u00e1sio H.","journal-title":"Advanced Steel Construction"},{"key":"atypb8","doi-asserted-by":"publisher","DOI":"10.1127\/0941-2948\/2006\/0130"},{"key":"atypb9","volume-title":"ICSA2010 - International Conference on Structures and Architecture","author":"Murtinho V."},{"key":"atypb10","volume-title":"Portuguese Law: Decreto-Lei n 80\/2006, Regulamento das Caracter\u00edsticas Termicas dos Edificios (in Portuguese)","author":"Rccte","year":"2006"},{"key":"atypb11","volume-title":"Buildings and Climate Change: Status, Challenges and Opportunities","author":"United Nations Environmental Programme (UNEP)","year":"2007"}],"container-title":["Journal of Building Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/1744259111403440","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/1744259111403440","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T21:22:11Z","timestamp":1777497731000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/1744259111403440"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,5,24]]},"references-count":11,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2011,7]]}},"alternative-id":["10.1177\/1744259111403440"],"URL":"https:\/\/doi.org\/10.1177\/1744259111403440","relation":{},"ISSN":["1744-2591","1744-2583"],"issn-type":[{"value":"1744-2591","type":"print"},{"value":"1744-2583","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,5,24]]}}}