{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,19]],"date-time":"2026-02-19T07:35:07Z","timestamp":1771486507016,"version":"3.50.1"},"reference-count":31,"publisher":"SAGE Publications","issue":"1","license":[{"start":{"date-parts":[[2012,8,2]],"date-time":"2012-08-02T00:00:00Z","timestamp":1343865600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Journal of Building Physics"],"published-print":{"date-parts":[[2013,7]]},"abstract":"<jats:p> Treating rising damp in the walls of historical buildings is complex because moisture transfer into the walls of old buildings in direct contact with the ground leads to the migration of soluble salts. This work analyzes rising damp using concepts and methods of unsaturated moisture flow theory, and a numerical validation study. A simple analytical model describes the rising damp front for the simplified situation of a monolithic wall. The influence of wall thickness, boundary conditions, wall composition, and material properties, such as porosity and sorptivity, are analyzed in detail. <\/jats:p>","DOI":"10.1177\/1744259112453822","type":"journal-article","created":{"date-parts":[[2012,8,4]],"date-time":"2012-08-04T00:29:39Z","timestamp":1344040179000},"page":"6-27","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":26,"title":["Rising damp in walls: Evaluation of the level achieved by the damp front"],"prefix":"10.1177","volume":"37","author":[{"given":"Ana S","family":"Guimar\u00e3es","sequence":"first","affiliation":[{"name":"Laborat\u00f3rio de F\u00edsica das Constru\u00e7\u00f5es (LFC), Departamento de Engenharia Civil, Faculdade de Engenharia da Universidade do Porto, Portugal"}]},{"given":"Jo\u00e3o MPQ","family":"Delgado","sequence":"additional","affiliation":[{"name":"Laborat\u00f3rio de F\u00edsica das Constru\u00e7\u00f5es (LFC), Departamento de Engenharia Civil, Faculdade de Engenharia da Universidade do Porto, Portugal"}]},{"given":"Vasco P","family":"de Freitas","sequence":"additional","affiliation":[{"name":"Laborat\u00f3rio de F\u00edsica das Constru\u00e7\u00f5es (LFC), Departamento de Engenharia Civil, Faculdade de Engenharia da Universidade do Porto, Portugal"}]}],"member":"179","published-online":{"date-parts":[[2012,8,2]]},"reference":[{"key":"bibr1-1744259112453822","unstructured":"Allen RG, Pereira LS, Raes D, (1998) Crop Evapotranspiration (Guidelines for Computing Crop Water Requirements), FAO Irrigation and Drainage Paper 56. Rome: Food and Agriculture Organization of the United Nations, pp. 290."},{"issue":"2","key":"bibr2-1744259112453822","first-page":"1","volume":"43","author":"Allen RG","year":"1994","journal-title":"ICID Bulletin"},{"key":"bibr3-1744259112453822","unstructured":"Bomberg M (1974) Moisture Flow Through Porous Building Materials. Report no. 52. Lund: Division of Building Technology, Lund Institute of Technology, pp. 188."},{"key":"bibr4-1744259112453822","doi-asserted-by":"publisher","DOI":"10.1177\/1744259109355730"},{"key":"bibr5-1744259112453822","doi-asserted-by":"publisher","DOI":"10.1016\/0360-1323(95)00027-5"},{"key":"bibr6-1744259112453822","doi-asserted-by":"crossref","unstructured":"Freitas VP, Guimar\u00e3es AS, Delgado JMPQ (2011) The \u201cHumivent\u201d device for rising damp treatment. Recent Patents on Engineering 5(3): 233\u2013240.","DOI":"10.2174\/187221211797636863"},{"issue":"1","key":"bibr7-1744259112453822","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1017\/S0021859600001441","volume":"4","author":"Green WH","year":"1911","journal-title":"Journal of Agricultural Science"},{"key":"bibr8-1744259112453822","doi-asserted-by":"publisher","DOI":"10.1016\/j.buildenv.2010.05.007"},{"key":"bibr9-1744259112453822","doi-asserted-by":"publisher","DOI":"10.1016\/0360-1323(80)90015-3"},{"key":"bibr10-1744259112453822","doi-asserted-by":"publisher","DOI":"10.1016\/0360-1323(81)90013-5"},{"key":"bibr11-1744259112453822","doi-asserted-by":"publisher","DOI":"10.1016\/0360-1323(77)90040-3"},{"key":"bibr12-1744259112453822","doi-asserted-by":"publisher","DOI":"10.1016\/0360-1323(81)90014-7"},{"key":"bibr13-1744259112453822","doi-asserted-by":"publisher","DOI":"10.1680\/macr.1989.41.147.51"},{"key":"bibr14-1744259112453822","doi-asserted-by":"publisher","DOI":"10.4324\/9780203301708"},{"key":"bibr15-1744259112453822","doi-asserted-by":"publisher","DOI":"10.1098\/rspa.2007.1855"},{"key":"bibr16-1744259112453822","doi-asserted-by":"publisher","DOI":"10.1016\/0360-1323(86)90017-X"},{"key":"bibr17-1744259112453822","doi-asserted-by":"publisher","DOI":"10.1016\/0360-1323(84)90009-X"},{"key":"bibr18-1744259112453822","doi-asserted-by":"publisher","DOI":"10.1016\/S0008-8846(03)00070-X"},{"key":"bibr19-1744259112453822","volume-title":"Proceedings of the international workshop on climate data and their applications in engineering","author":"Hensen JLM","year":"1999"},{"key":"bibr20-1744259112453822","first-page":"363","volume-title":"Proceedings of the 2nd international conference on building physics","author":"Holm A","year":"2003"},{"key":"bibr21-1744259112453822","doi-asserted-by":"publisher","DOI":"10.1177\/1744259106060439"},{"key":"bibr22-1744259112453822","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhydrol.2008.06.005"},{"key":"bibr23-1744259112453822","doi-asserted-by":"publisher","DOI":"10.2136\/sssaj1976.03615995004000010010x"},{"key":"bibr24-1744259112453822","unstructured":"Kunzel HM (1995) Simultaneous Heat and Moisture Transport in Building Components: One- and Two-Dimensional Calculation Using Simple Parameters. PhD Thesis, Fraunhofer Institute of Building Physics, Holzkirchen, Germany. Stuttgart, Germany: Fraunhofer IRB Verlag."},{"key":"bibr25-1744259112453822","volume-title":"Meteonorm \u2013 Version 6.0","author":"METEOTEST","year":"2008"},{"key":"bibr26-1744259112453822","first-page":"205","volume-title":"19th Symposia of the society for experimental biology","author":"Monteith JL","year":"1965"},{"key":"bibr27-1744259112453822","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhydrol.2004.08.026"},{"key":"bibr28-1744259112453822","doi-asserted-by":"publisher","DOI":"10.1016\/B978-1-4831-9936-8.50010-6"},{"key":"bibr29-1744259112453822","volume-title":"Boundary-Layer Theory","author":"Schlichting H","year":"2004","edition":"8"},{"key":"bibr30-1744259112453822","doi-asserted-by":"publisher","DOI":"10.1016\/j.buildenv.2005.07.034"},{"key":"bibr31-1744259112453822","doi-asserted-by":"publisher","DOI":"10.1016\/0360-1323(94)90013-2"}],"container-title":["Journal of Building Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/1744259112453822","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/1744259112453822","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/1744259112453822","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,3]],"date-time":"2025-03-03T11:09:12Z","timestamp":1741000152000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/1744259112453822"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,8,2]]},"references-count":31,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2013,7]]}},"alternative-id":["10.1177\/1744259112453822"],"URL":"https:\/\/doi.org\/10.1177\/1744259112453822","relation":{},"ISSN":["1744-2591","1744-2583"],"issn-type":[{"value":"1744-2591","type":"print"},{"value":"1744-2583","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,8,2]]}}}