{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T22:35:55Z","timestamp":1791412555476,"version":"4.3.3"},"reference-count":62,"publisher":"European Respiratory Society (ERS)","issue":"155","license":[{"start":{"date-parts":[[2020,2,12]],"date-time":"2020-02-12T00:00:00Z","timestamp":1581465600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["publications.ersnet.org"],"crossmark-restriction":true},"short-container-title":["Eur Respir Rev"],"accepted":{"date-parts":[[2019,10,21]]},"published-print":{"date-parts":[[2020,3,31]]},"abstract":"<jats:p>Although several guidelines recommend subglottic secretion drainage as a strategy for prevention of ventilator-associated pneumonia (VAP), its use is not widespread. With the aim to assess the effectiveness of subglottic secretion drainage for preventing VAP and to improve other outcomes such as mortality, duration of mechanical ventilation and length of stay in the intensive care unit (ICU) or hospital, an electronic search of the Cochrane Library, MEDLINE, Web of Science and Embase was undertaken. Nine systematic reviews with meta-analysis (in the overview of reviews) and 20 randomised controlled trials (in the updated meta-analysis) were included.<\/jats:p><jats:p>In the overview of reviews, all systematic reviews with meta-analysis included found a positive effect of subglottic secretion drainage in the reduction of incidence of VAP. In the updated meta-analysis, subglottic secretion drainage significantly reduced VAP incidence (risk ratio (RR) 0.56, 95% CI 0.48\u20130.63; I<jats:sup>2<\/jats:sup>=0%, p=0.841) and mortality (RR 0.88, 95% CI 0.80\u20130.97; I<jats:sup>2<\/jats:sup>=0%, p=0.888).<\/jats:p><jats:p>This is the first study that has found a decrease of mortality associated with the use of subglottic secretion drainage. In addition, subglottic secretion drainage is an effective measure to reduce VAP incidence, despite not improving the duration of mechanical ventilation and ICU and\/or hospital length of stay.<\/jats:p>","DOI":"10.1183\/16000617.0107-2019","type":"journal-article","created":{"date-parts":[[2020,2,26]],"date-time":"2020-02-26T11:30:51Z","timestamp":1582716651000},"page":"190107","update-policy":"https:\/\/doi.org\/10.1183\/ers-crossmark-policy","source":"Crossref","is-referenced-by-count":86,"title":["Subglottic secretion drainage for preventing ventilator-associated pneumonia: an overview of systematic reviews and an updated meta-analysis"],"prefix":"10.1183","volume":"29","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0527-5498","authenticated-orcid":false,"given":"Diana P.","family":"Pozuelo-Carrascosa","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2691-0315","authenticated-orcid":false,"given":"\u00c1ngel","family":"Herr\u00e1iz-Adillo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Celia","family":"Alvarez-Bueno","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jose Manuel","family":"A\u00f1\u00f3n","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vicente","family":"Mart\u00ednez-Vizca\u00edno","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Iv\u00e1n","family":"Cavero-Redondo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"81","published-online":{"date-parts":[[2020,2,12]]},"reference":[{"key":"2024102403435491000_29.155.190107.1","doi-asserted-by":"publisher","DOI":"10.1177\/0885066606288837"},{"key":"2024102403435491000_29.155.190107.2","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1016\/j.ccc.2016.12.009","article-title":"Ventilator-associated pneumonia: new definitions","volume":"33","author":"Spalding","year":"2017","journal-title":"Crit Care Clin"},{"key":"2024102403435491000_29.155.190107.3","doi-asserted-by":"publisher","DOI":"10.1016\/S1473-3099(13)70081-1"},{"key":"2024102403435491000_29.155.190107.4","doi-asserted-by":"publisher","DOI":"10.1086\/664049"},{"key":"2024102403435491000_29.155.190107.5","doi-asserted-by":"crossref","first-page":"32","DOI":"10.4037\/ccn2007.27.4.32","article-title":"Ventilator-associated pneumonia: risk factors and prevention","volume":"27","author":"Augustyn","year":"2007","journal-title":"Crit Care Nurse"},{"key":"2024102403435491000_29.155.190107.6","doi-asserted-by":"publisher","DOI":"10.2174\/187152611796504827"},{"key":"2024102403435491000_29.155.190107.7","doi-asserted-by":"publisher","DOI":"10.4187\/respcare.02380"},{"key":"2024102403435491000_29.155.190107.8","doi-asserted-by":"publisher","DOI":"10.4187\/respcare.05492"},{"key":"2024102403435491000_29.155.190107.9","doi-asserted-by":"publisher","DOI":"10.1086\/677216"},{"key":"2024102403435491000_29.155.190107.10","first-page":"1","article-title":"Guidelines for preventing health-care-associated pneumonia, 2003: recommendations of CDC and the Healthcare Infection Control Practices Advisory Committee","volume":"53","author":"Tablan","year":"2004","journal-title":"MMWR Recomm Rep"},{"key":"2024102403435491000_29.155.190107.11","doi-asserted-by":"publisher","DOI":"10.1086\/677144"},{"key":"2024102403435491000_29.155.190107.12","doi-asserted-by":"publisher","DOI":"10.1097\/CCM.0000000000002736"},{"key":"2024102403435491000_29.155.190107.13","doi-asserted-by":"publisher","DOI":"10.1093\/ptj\/89.9.873"},{"key":"2024102403435491000_29.155.190107.14","unstructured":"Higgins JP , Green S . Cochrane Handbook for Systematic Reviews of Interventions Version 5.1.0. Cochrane Collaboration 2011 http:\/\/handbook-5-1.cochrane.org\/"},{"key":"2024102403435491000_29.155.190107.15","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.j4008"},{"key":"2024102403435491000_29.155.190107.16","doi-asserted-by":"publisher","DOI":"10.1016\/j.jclinepi.2010.07.015"},{"key":"2024102403435491000_29.155.190107.17","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.39489.470347.AD"},{"key":"2024102403435491000_29.155.190107.18","unstructured":"Sch\u00fcnemann H BJ, Guyatt G, Oxman A, editors. GRADE Handbook for Grading Quality of Evidence and Strength of Recommendations. The GRADE Working Group, 2013. www.guidelinedevelopment.org\/handbook Date last updated: October 2013."},{"key":"2024102403435491000_29.155.190107.19","doi-asserted-by":"publisher","DOI":"10.1016\/j.jclinepi.2009.06.005"},{"key":"2024102403435491000_29.155.190107.20","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.d5928"},{"key":"2024102403435491000_29.155.190107.21","first-page":"719","article-title":"Statistical aspects of the analysis of data from retrospective studies of disease","volume":"22","author":"Mantel","year":"1959","journal-title":"J Natl Cancer Inst"},{"key":"2024102403435491000_29.155.190107.22","doi-asserted-by":"publisher","DOI":"10.1016\/0197-2456(86)90046-2"},{"key":"2024102403435491000_29.155.190107.23","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.315.7109.629"},{"key":"2024102403435491000_29.155.190107.24","first-page":"586","article-title":"[Comprehensive effect of subglottic secretion drainage on patients with mechanical ventilation in ICU: a meta-analysis]","volume":"29","author":"Sun","year":"2017","journal-title":"Zhonghua Wei Zhong Bing Ji Jiu Yi Xue"},{"key":"2024102403435491000_29.155.190107.25","doi-asserted-by":"publisher","DOI":"10.1186\/s13054-016-1527-7"},{"key":"2024102403435491000_29.155.190107.26","doi-asserted-by":"publisher","DOI":"10.1097\/CCM.0000000000001414"},{"key":"2024102403435491000_29.155.190107.27","doi-asserted-by":"publisher","DOI":"10.1016\/j.aucc.2013.03.003"},{"key":"2024102403435491000_29.155.190107.28","doi-asserted-by":"publisher","DOI":"10.1097\/DCC.0b013e3182445ff3"},{"key":"2024102403435491000_29.155.190107.29","doi-asserted-by":"publisher","DOI":"10.1097\/CCM.0b013e318218a4d9"},{"key":"2024102403435491000_29.155.190107.30","doi-asserted-by":"publisher","DOI":"10.1097\/TA.0b013e318247cd33"},{"key":"2024102403435491000_29.155.190107.31","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjmed.2004.07.051"},{"key":"2024102403435491000_29.155.190107.32","doi-asserted-by":"publisher","DOI":"10.1097\/MD.0000000000011223"},{"key":"2024102403435491000_29.155.190107.33","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1016\/j.jcrc.2016.11.007","article-title":"A prospective randomized trial of tapered-cuff endotracheal tubes with intermittent subglottic suctioning in preventing ventilator-associated pneumonia in critically ill patients","volume":"38","author":"Mahmoodpoor","year":"2017","journal-title":"J Crit Care"},{"key":"2024102403435491000_29.155.190107.34","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1513\/AnnalsATS.201506-346OC","article-title":"Randomized pilot trial of two modified endotracheal tubes to prevent ventilator-associated pneumonia","volume":"13","author":"Deem","year":"2016","journal-title":"Ann Am Thorac Soc"},{"key":"2024102403435491000_29.155.190107.35","doi-asserted-by":"crossref","first-page":"261","DOI":"10.4103\/0972-5229.182196","article-title":"Comparison of suction above cuff and standard endotracheal tubes in neurological patients for the incidence of ventilator-associated pneumonia and in-hospital outcome: a randomized controlled pilot study","volume":"20","author":"Jena","year":"2016","journal-title":"Indian J Crit Care Med"},{"key":"2024102403435491000_29.155.190107.36","doi-asserted-by":"publisher","DOI":"10.1093\/ejcts\/ezu483"},{"key":"2024102403435491000_29.155.190107.37","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1097\/CCM.0000000000000674","article-title":"Prevention of ventilator-associated pneumonia and ventilator-associated conditions: a randomized controlled trial with subglottic secretion suctioning","volume":"43","author":"Damas","year":"2015","journal-title":"Crit Care Med"},{"key":"2024102403435491000_29.155.190107.38","first-page":"283","article-title":"[Effect of two methods of subglottic secretion drainage on the incidence of ventilator-associated pneumonia]","volume":"37","author":"Tao","year":"2014","journal-title":"Zhonghua Jie He He Hu Xi Za Zhi"},{"key":"2024102403435491000_29.155.190107.39","first-page":"58","article-title":"Effect of subglottic secretion drainage on the ventilator-associated pneumonia in ICU patients","volume":"15","author":"Seyfi","year":"2013","journal-title":"J Babol Univ Med Sci"},{"key":"2024102403435491000_29.155.190107.40","doi-asserted-by":"publisher","DOI":"10.1164\/rccm.200906-0838OC"},{"key":"2024102403435491000_29.155.190107.41","first-page":"338","article-title":"[A clinical study of subglottic secretion drainage for prevention of ventilation associated pneumonia]","volume":"20","author":"Zheng","year":"2008","journal-title":"Zhongguo Wei Zhong Bing Ji Jiu Yi Xue"},{"key":"2024102403435491000_29.155.190107.42","first-page":"625","article-title":"[Effect of continuous aspiration of subglottic secretions on the prevention of ventilator-associated pneumonia in mechanically ventilated patients: a prospective, randomized, controlled clinical trial]","volume":"47","author":"Yang","year":"2008","journal-title":"Zhonghua Nei Ke Za Zhi"},{"key":"2024102403435491000_29.155.190107.43","doi-asserted-by":"publisher","DOI":"10.1378\/chest.08-0103"},{"key":"2024102403435491000_29.155.190107.44","doi-asserted-by":"publisher","DOI":"10.1164\/rccm.200705-761OC"},{"key":"2024102403435491000_29.155.190107.45","first-page":"717","article-title":"[Comprehensive prevention and pathogenesis of ventilator-associated pneumonia in elderly patients: a prospective, randomized, case-control clinical trial]","volume":"45","author":"Liu","year":"2006","journal-title":"Zhonghua Nei Ke Za Zhi"},{"key":"2024102403435491000_29.155.190107.46","first-page":"19","article-title":"[The effect of subglottic secretion drainage on prevention of ventilator-associated lower airway infection]","volume":"29","author":"Liu","year":"2006","journal-title":"Zhonghua Jie He He Hu Xi Za Zhi"},{"key":"2024102403435491000_29.155.190107.47","doi-asserted-by":"publisher","DOI":"10.1007\/s00134-003-2077-4"},{"key":"2024102403435491000_29.155.190107.48","doi-asserted-by":"publisher","DOI":"10.1378\/chest.121.3.858"},{"key":"2024102403435491000_29.155.190107.49","first-page":"472","article-title":"[Influence of the subglottic secretion drainage on the morbidity of ventilator associated pneumonia in mechanically ventilated patients]","volume":"23","author":"Bo","year":"2000","journal-title":"Zhonghua Jie He He Hu Xi Za Zhi"},{"key":"2024102403435491000_29.155.190107.50","doi-asserted-by":"publisher","DOI":"10.1378\/chest.116.5.1339"},{"key":"2024102403435491000_29.155.190107.51","doi-asserted-by":"publisher","DOI":"10.7326\/0003-4819-122-3-199502010-00004"},{"key":"2024102403435491000_29.155.190107.52","doi-asserted-by":"publisher","DOI":"10.1007\/BF01706421"},{"key":"2024102403435491000_29.155.190107.53","doi-asserted-by":"crossref","first-page":"422","DOI":"10.21037\/atm.2018.10.40","article-title":"Subglottic secretion drainage for ventilator-associated pneumonia prevention: an underused efficient measure","volume":"6","author":"Lacherade","year":"2018","journal-title":"Ann Transl Med"},{"key":"2024102403435491000_29.155.190107.54","doi-asserted-by":"publisher","DOI":"10.1378\/chest.122.6.2115"},{"key":"2024102403435491000_29.155.190107.55","unstructured":"SARI Working Group. Guidelines for the Prevention of Ventilator-Associated Pneumonia in Adults in Ireland. Dublin, HSE Health Protection Surveillance Centre (HPSC), 2011."},{"key":"2024102403435491000_29.155.190107.56","doi-asserted-by":"publisher","DOI":"10.1164\/rccm.200405-644ST"},{"key":"2024102403435491000_29.155.190107.57","doi-asserted-by":"crossref","first-page":"2655","DOI":"10.22207\/JPAM.10.4.23","article-title":"Early replacement of conventional endotracheal tube with endotracheal tube with subglottic suction port for the new intensive care patients; preventive or problematic against ventilator associated events?","volume":"10","author":"Masjedi","year":"2016","journal-title":"J Pure Appl Microbio"},{"key":"2024102403435491000_29.155.190107.58","doi-asserted-by":"publisher","DOI":"10.1186\/1756-0500-4-92"},{"key":"2024102403435491000_29.155.190107.59","doi-asserted-by":"crossref","first-page":"446","DOI":"10.1186\/cc11464","article-title":"Number needed to treat for subglottic secretion drainage technology as a ventilator-associated pneumonia prevention strategy","volume":"16","author":"Kelley","year":"2012","journal-title":"Crit Care"},{"key":"2024102403435491000_29.155.190107.60","first-page":"15","article-title":"Comparative effectiveness of standard endotracheal tubes vs. endotracheal tubes with continuous subglottic suctioning on ventilator-associated pneumonia rates","volume":"29","author":"Speroni","year":"2011","journal-title":"Nurs Econ"},{"key":"2024102403435491000_29.155.190107.61","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1086\/657943","article-title":"Is continuous subglottic suctioning cost-effective for the prevention of ventilator-associated pneumonia?","volume":"32","author":"Hallais","year":"2011","journal-title":"Infect Control Hosp Epidemiol"},{"key":"2024102403435491000_29.155.190107.62","doi-asserted-by":"publisher","DOI":"10.4037\/ccn2017940"}],"updated-by":[{"DOI":"10.1183\/16000617.5107-2019","type":"correction","label":"Correction","source":"publisher","updated":{"date-parts":[[2022,3,23]],"date-time":"2022-03-23T00:00:00Z","timestamp":1647993600000}}],"container-title":["European Respiratory Review"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1183\/16000617.0107-2019","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,2,24]],"date-time":"2025-02-24T05:05:00Z","timestamp":1740373500000},"score":1,"resource":{"primary":{"URL":"https:\/\/publications.ersnet.org\/lookup\/doi\/10.1183\/16000617.0107-2019"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,2,12]]},"references-count":62,"journal-issue":{"issue":"155","published-online":{"date-parts":[[2020,2,12]]},"published-print":{"date-parts":[[2020,3,31]]}},"alternative-id":["10.1183\/16000617.0107-2019"],"URL":"https:\/\/doi.org\/10.1183\/16000617.0107-2019","relation":{"correction":[{"id-type":"doi","id":"10.1183\/16000617.5107-2019","asserted-by":"object"}]},"ISSN":["0905-9180","1600-0617"],"issn-type":[{"value":"0905-9180","type":"print"},{"value":"1600-0617","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,2,12]]}}}