{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,22]],"date-time":"2026-09-22T22:31:58Z","timestamp":1790116318468,"version":"4.0.1"},"reference-count":30,"publisher":"European Respiratory Society (ERS)","issue":"4","license":[{"start":{"date-parts":[[2025,10,1]],"date-time":"2025-10-01T00:00:00Z","timestamp":1759276800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["publications.ersnet.org"],"crossmark-restriction":true},"short-container-title":["Breathe"],"accepted":{"date-parts":[[2025,10,15]]},"published-print":{"date-parts":[[2025,10]]},"abstract":"<jats:p>Pleural effusion represents a frequent and diagnostically challenging condition across multiple clinical settings. Conventional characterisation relies on invasive thoracentesis and biochemical analysis, with Light's criteria offering high sensitivity but limited specificity. Procedural risks and patient factors may limit fluid sampling, highlighting the need for complementary, noninvasive approaches. Recent advances in thoracic ultrasound (TUS) suggest that quantitative assessment of pleural fluid (PF) echogenicity, particularly pixel density analysis and hypoechogenicity index, may represent an investigational approach for objective and reproducible evaluation. Preliminary studies using standardised image analysis platforms, such as ImageJ, indicate that exudative effusions more frequently exhibit higher pixel density than transudates, in association with markers of cellularity, protein content, and inflammation. Hybrid scoring systems combining quantitative metrics with morphological sonographic features, such as septations, fibrin strands, and debris, have been explored and may enhance diagnostic specificity, although validation remains limited. However, methodological constraints, operator- and device-dependent variability and small sample sizes continue to restrict their applicability in routine clinical practice. Emerging approaches, including artificial intelligence, may be able to mitigate these limitations by standardising measurements, harmonising grayscale output, and integrating clinical, laboratory and imaging data to generate real-time risk scores. In the absence of robustly validated evidence, quantitative TUS should be regarded as an investigational adjunct, with potential to refine PF characterisation, support clinical decision-making, and inform future research on noninvasive diagnostic strategies.<\/jats:p>","DOI":"10.1183\/20734735.0282-2025","type":"journal-article","created":{"date-parts":[[2025,12,16]],"date-time":"2025-12-16T09:30:12Z","timestamp":1765877412000},"page":"250282","update-policy":"https:\/\/doi.org\/10.1183\/ers-crossmark-policy","source":"Crossref","is-referenced-by-count":8,"title":["Exploring pleural effusion characterisation with quantitative thoracic ultrasound imaging: a viewpoint on the investigational role of pixel-based echogenicity analysis in transudate and exudate differentiation"],"prefix":"10.1183","volume":"21","author":[{"ORCID":"https:\/\/orcid.org\/0009-0000-6122-7792","authenticated-orcid":false,"given":"Guido","family":"Marchi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"81","published-online":{"date-parts":[[2025,12,16]]},"reference":[{"key":"2025121601300716000_21.4.250282.1","unstructured":"Light RW . Pleural Diseases. 5th Edn. Philadelphia, Lippincott Williams & Wilkins, 2007."},{"key":"2025121601300716000_21.4.250282.2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMra1403503"},{"key":"2025121601300716000_21.4.250282.3","doi-asserted-by":"publisher","DOI":"10.1016\/j.chest.2021.05.026"},{"key":"2025121601300716000_21.4.250282.4","doi-asserted-by":"crossref","first-page":"213","DOI":"10.7861\/clinmedicine.19-3-213","article-title":"Interpreting pleural fluid results","volume":"19","author":"Mercer","year":"2019","journal-title":"Clin Med (Lond)"},{"key":"2025121601300716000_21.4.250282.5","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1016\/j.ccm.2012.11.006","article-title":"The Light criteria","volume":"34","author":"Light","year":"2013","journal-title":"Clin Chest Med"},{"key":"2025121601300716000_21.4.250282.6","doi-asserted-by":"crossref","first-page":"828","DOI":"10.1016\/j.chest.2025.06.001","article-title":"Pleural fluid analysis: maximizing diagnostic yield in the pleural effusion evaluation","volume":"168","author":"Chopra","year":"2025","journal-title":"Chest"},{"key":"2025121601300716000_21.4.250282.7","doi-asserted-by":"publisher","DOI":"10.1111\/j.1440-1843.2010.01794.x"},{"key":"2025121601300716000_21.4.250282.8","doi-asserted-by":"crossref","first-page":"378","DOI":"10.1097\/MCP.0000000000000285","article-title":"Complications of thoracentesis: incidence, risk factors, and strategies for prevention","volume":"22","author":"Cantey","year":"2016","journal-title":"Curr Opin Pulm Med"},{"key":"2025121601300716000_21.4.250282.9","first-page":"e20230395","article-title":"Thoracic ultrasound: a review of the state-of-the-art","volume":"50","author":"Colares","year":"2024","journal-title":"J Bras Pneumol"},{"key":"2025121601300716000_21.4.250282.10","doi-asserted-by":"publisher","DOI":"10.1183\/13993003.01519-2020"},{"key":"2025121601300716000_21.4.250282.11","doi-asserted-by":"crossref","first-page":"250179","DOI":"10.1183\/20734735.0179-2025","article-title":"The road less travelled: thoracic ultrasound, advanced imaging, and artificial intelligence for early diagnosis of non-expandable lung in malignant pleural effusion","volume":"21","author":"Marchi","year":"2025","journal-title":"Breathe (Sheff)"},{"key":"2025121601300716000_21.4.250282.12","doi-asserted-by":"publisher","DOI":"10.1183\/16000617.0136-2019"},{"key":"2025121601300716000_21.4.250282.13","doi-asserted-by":"crossref","first-page":"2062","DOI":"10.3390\/jcm14062062","article-title":"Thoracic ultrasound for pre-procedural dynamic assessment of non-expandable lung: a non-invasive, real-time and multifaceted diagnostic tool","volume":"14","author":"Marchi","year":"2025","journal-title":"J Clin Med"},{"key":"2025121601300716000_21.4.250282.14","doi-asserted-by":"crossref","first-page":"6326","DOI":"10.3390\/jcm14176326","article-title":"Intercostal artery screening with color Doppler thoracic ultrasound in pleural procedures: a potential yet underexplored imaging modality for minimizing iatrogenic bleeding risk in interventional pulmonology","volume":"14","author":"Marchi","year":"2025","journal-title":"J Clin Med"},{"key":"2025121601300716000_21.4.250282.15","doi-asserted-by":"crossref","first-page":"108296","DOI":"10.1016\/j.rmed.2025.108296","article-title":"The accuracy of thoracic ultrasound in differentiating transudative from exudative effusions: a meta-analysis","volume":"247","author":"Kummerfeldt","year":"2025","journal-title":"Respir Med"},{"key":"2025121601300716000_21.4.250282.16","doi-asserted-by":"publisher","DOI":"10.2214\/ajr.159.1.1609716"},{"key":"2025121601300716000_21.4.250282.17","doi-asserted-by":"publisher","DOI":"10.1097\/MD.0000000000030119"},{"key":"2025121601300716000_21.4.250282.18","doi-asserted-by":"publisher","DOI":"10.1159\/000496153"},{"key":"2025121601300716000_21.4.250282.19","doi-asserted-by":"publisher","DOI":"10.1016\/j.ultrasmedbio.2007.09.009"},{"key":"2025121601300716000_21.4.250282.20","doi-asserted-by":"publisher","DOI":"10.1016\/j.chest.2020.02.051"},{"key":"2025121601300716000_21.4.250282.21","doi-asserted-by":"crossref","first-page":"543","DOI":"10.21037\/jtd.2017.03.31","article-title":"Correlation of pleural effusions\u2019 grayscale sonographic parameters with fluid's analysis results","volume":"9","author":"Kalkanis","year":"2017","journal-title":"J Thorac Dis"},{"key":"2025121601300716000_21.4.250282.22","doi-asserted-by":"publisher","DOI":"10.1038\/nmeth.2089"},{"key":"2025121601300716000_21.4.250282.23","first-page":"1283590","article-title":"The use of a novel quantitative marker of echogenicity of pleural fluid in parapneumonic pleural effusions","volume":"2020","author":"Varsamas","year":"2020","journal-title":"Can Respir J"},{"key":"2025121601300716000_21.4.250282.24","doi-asserted-by":"publisher","DOI":"10.1513\/AnnalsATS.202105-548RL"},{"key":"2025121601300716000_21.4.250282.25","doi-asserted-by":"crossref","first-page":"117","DOI":"10.4103\/atm.atm_192_23","article-title":"Artificial intelligence in respiratory care: current scenario and future perspective","volume":"19","author":"Al-Anazi","year":"2024","journal-title":"Ann Thorac Med"},{"key":"2025121601300716000_21.4.250282.26","first-page":"E285","article-title":"Perspectives on AI use in medicine: views of the Italian Society of Artificial Intelligence in Medicine","volume":"65","author":"Causio","year":"2024","journal-title":"J Prev Med Hyg"},{"key":"2025121601300716000_21.4.250282.27","doi-asserted-by":"publisher","DOI":"10.1183\/16000617.0263-2024"},{"key":"2025121601300716000_21.4.250282.28","doi-asserted-by":"crossref","first-page":"429","DOI":"10.1007\/s40477-023-00866-5","article-title":"New perspectives on the use of artificial intelligence in the ultrasound evaluation of lung diseases","volume":"27","author":"Boccatonda","year":"2024","journal-title":"J Ultrasound"},{"key":"2025121601300716000_21.4.250282.29","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1001\/jamacardio.2024.4991","article-title":"Artificial intelligence-guided lung ultrasound by nonexperts","volume":"10","author":"Baloescu","year":"2025","journal-title":"JAMA Cardiol"},{"key":"2025121601300716000_21.4.250282.30","first-page":"17","article-title":"Artificial intelligence and democratization of the use of lung ultrasound in COVID-19: on the feasibility of automatic calculation of lung ultrasound score","volume":"2","author":"Camacho","year":"2022","journal-title":"Int J Transl Med"}],"container-title":["Breathe"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1183\/20734735.0282-2025","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,12,16]],"date-time":"2025-12-16T09:30:18Z","timestamp":1765877418000},"score":1,"resource":{"primary":{"URL":"http:\/\/publications.ersnet.org\/lookup\/doi\/10.1183\/20734735.0282-2025"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10]]},"references-count":30,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2025,12,16]]},"published-print":{"date-parts":[[2025,10]]}},"alternative-id":["10.1183\/20734735.0282-2025"],"URL":"https:\/\/doi.org\/10.1183\/20734735.0282-2025","relation":{},"ISSN":["1810-6838","2073-4735"],"issn-type":[{"value":"1810-6838","type":"print"},{"value":"2073-4735","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,10]]}}}