{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T02:12:12Z","timestamp":1790820732036,"version":"4.1.0"},"reference-count":20,"publisher":"European Respiratory Society (ERS)","issue":"1","license":[{"start":{"date-parts":[[2021,12,10]],"date-time":"2021-12-10T00:00:00Z","timestamp":1639094400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["publications.ersnet.org"],"crossmark-restriction":true},"short-container-title":["ERJ Open Res"],"accepted":{"date-parts":[[2021,11,24]]},"published-print":{"date-parts":[[2022,1]]},"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>\n                      Computed tomography (CT) screening has improved lung cancer survival, yet increasingly detects small lung lesions. Thus, the number of transthoracic lung biopsies (TTLB) for small nodules is expected to rise significantly. The aim of the present study was to evaluate the diagnostic accuracy and safety of CT-guided TTLB for nodules \u226420\u2005mm\n                      <jats:italic>versus<\/jats:italic>\n                      nodules &gt;20\u2005mm.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Study design and methods<\/jats:title>\n                    <jats:p>Data for CT-guided TTLBs from 474 consecutive patients were prospectively collected over a 3-year period (198 lesions \u226420\u2005mm and 276 lesions &gt;20\u2005mm) in a teaching hospital and analysed in terms of diagnostic performance and complications.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      There were more conclusive biopsies in the &gt;20\u2005mm lesion group (n=236, 85.5%) than in \u226420\u2005mm lesion group (n=140, 70.7%; p&lt;0.001). The overall accuracy, sensitivity, specificity and negative predictive value for diagnosing malignant lesions after first TTLB were 88.4%, 84%, 100% and 70.1%, respectively, for \u226420\u2005mm lesions, and 94.2%, 93%, 100% and 74.6%, respectively, for &gt;20\u2005mm lesions. Pneumothorax requiring drainage was significantly more common for \u226420\u2005mm lesions, compared to TTLB of larger lesions (9.6%\n                      <jats:italic>versus<\/jats:italic>\n                      4.3%; p=0.02). Prolonged hospital stay due to pneumothorax occurred in 27 (17.4%) TTLBs of \u226420\u2005mm lesions and 15 (7%) TTLBs of &gt;20\u2005mm lesions (p=0.002). There were no deaths. The only variable significantly associated with diagnostic failure in the \u226420\u2005mm lesion group was the radiologist's experience.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Interpretation<\/jats:title>\n                    <jats:p>TTLBs for lesions \u226420\u2005mm were associated with slightly lower diagnostic performance, whereas the higher rate of major complications was still inferior to that extrapolated from United States insurance databases.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1183\/23120541.00562-2021","type":"journal-article","created":{"date-parts":[[2021,12,10]],"date-time":"2021-12-10T06:00:19Z","timestamp":1639116019000},"page":"00562-2021","update-policy":"https:\/\/doi.org\/10.1183\/ers-crossmark-policy","source":"Crossref","is-referenced-by-count":11,"title":["Transthoracic lung biopsy for pulmonary nodules \u226420\u2005mm in routine clinical care"],"prefix":"10.1183","volume":"8","author":[{"given":"Emilie","family":"Lissavalid","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antoine","family":"Khalil","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5745-2513","authenticated-orcid":false,"given":"Ghassen","family":"Soussi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marie-Pierre","family":"Debray","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alice","family":"Guyard","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vincent","family":"Bunel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9906-0024","authenticated-orcid":false,"given":"Raphael","family":"Borie","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pierre","family":"Mordant","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aur\u00e9lie","family":"Cazes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"G\u00e9rard","family":"Zalcman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9473-1247","authenticated-orcid":false,"given":"Val\u00e9rie","family":"Gounant","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"81","published-online":{"date-parts":[[2021,12,10]]},"reference":[{"key":"2024101711263073000_8.1.00562-2021.1","doi-asserted-by":"publisher","DOI":"10.3322\/caac.21654"},{"key":"2024101711263073000_8.1.00562-2021.2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1102873"},{"key":"2024101711263073000_8.1.00562-2021.3","doi-asserted-by":"crossref","first-page":"503","DOI":"10.1056\/NEJMoa1911793","article-title":"Reduced lung-cancer mortality with volume CT screening in a randomized trial","volume":"382","author":"de Koning","year":"2020","journal-title":"N Engl J Med"},{"key":"2024101711263073000_8.1.00562-2021.4","doi-asserted-by":"crossref","first-page":"324","DOI":"10.1001\/jamainternmed.2018.6277","article-title":"Complication rates and downstream medical costs associated with invasive diagnostic procedures for lung abnormalities in the community setting","volume":"179","author":"Huo","year":"2019","journal-title":"JAMA Intern Med"},{"key":"2024101711263073000_8.1.00562-2021.5","doi-asserted-by":"crossref","first-page":"138","DOI":"10.1007\/s00330-016-4357-8","article-title":"Complication rates of CT-guided transthoracic lung biopsy: meta-analysis","volume":"27","author":"Heerink","year":"2017","journal-title":"Eur Radiol"},{"key":"2024101711263073000_8.1.00562-2021.6","doi-asserted-by":"crossref","first-page":"149","DOI":"10.4103\/1817-1737.134069","article-title":"Computer tomography-guided core biopsies in a county hospital in Sweden: complication rate and diagnostic yield","volume":"9","author":"Brand\u00e9n","year":"2014","journal-title":"Ann Thorac Med"},{"key":"2024101711263073000_8.1.00562-2021.7","doi-asserted-by":"crossref","first-page":"e16","DOI":"10.3747\/co.19.871","article-title":"Fine-needle aspiration biopsy versus core-needle biopsy in diagnosing lung cancer: a systematic review","volume":"19","author":"Yao","year":"2012","journal-title":"Curr Oncol"},{"key":"2024101711263073000_8.1.00562-2021.8","doi-asserted-by":"crossref","first-page":"e0154","DOI":"10.1097\/MD.0000000000010154","article-title":"Computed tomography-guided percutaneous transthoracic needle biopsy for solitary pulmonary nodules in diameter less than 20 mm","volume":"97","author":"Xu","year":"2018","journal-title":"Medicine"},{"key":"2024101711263073000_8.1.00562-2021.9","first-page":"527","article-title":"Percutaneous core needle biopsy for small (\u2264 10 mm) lung nodules: accurate diagnosis and complication rates","volume":"18","author":"Jae","year":"2012","journal-title":"Diagn Interv Radiol"},{"key":"2024101711263073000_8.1.00562-2021.10","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.12.10156"},{"key":"2024101711263073000_8.1.00562-2021.11","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1186\/s40644-019-0240-6","article-title":"Accuracy and complications of CT-guided pulmonary core biopsy in small nodules: a single-center experience","volume":"19","author":"Huang","year":"2019","journal-title":"Cancer Imaging"},{"key":"2024101711263073000_8.1.00562-2021.12","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.202.1.8988197"},{"key":"2024101711263073000_8.1.00562-2021.13","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2253011465"},{"key":"2024101711263073000_8.1.00562-2021.14","doi-asserted-by":"publisher","DOI":"10.1016\/j.crad.2007.09.003"},{"key":"2024101711263073000_8.1.00562-2021.15","doi-asserted-by":"crossref","first-page":"333","DOI":"10.21037\/jtd.2017.02.16","article-title":"CT-guided transthoracic core needle biopsy for small pulmonary lesions: diagnostic performance and adequacy for molecular testing","volume":"9","author":"Tian","year":"2017","journal-title":"J Thorac Dis"},{"key":"2024101711263073000_8.1.00562-2021.16","doi-asserted-by":"publisher","DOI":"10.1007\/s002700010067"},{"key":"2024101711263073000_8.1.00562-2021.17","doi-asserted-by":"crossref","first-page":"796","DOI":"10.1007\/s00330-017-5027-1","article-title":"Diagnostic feasibility and safety of CT-guided core biopsy for lung nodules less than or equal to 8 mm: a single-institution experience","volume":"28","author":"Chang","year":"2018","journal-title":"Eur Radiol"},{"key":"2024101711263073000_8.1.00562-2021.18","doi-asserted-by":"crossref","unstructured":"Najafi A , Al Ahmar M , Bonnet B , et al. The PEARL approach for CT-guided lung biopsy: assessment of complication rate. Radiology 2021; in press [https:\/\/doi.org\/10.1148\/radiol.2021210360]. doi:10.1148\/radiol.2021210360","DOI":"10.1148\/radiol.2021210360"},{"key":"2024101711263073000_8.1.00562-2021.19","doi-asserted-by":"crossref","first-page":"715","DOI":"10.1148\/radiology.198.3.8628859","article-title":"Transthoracic needle biopsy with a coaxially placed 20-gauge automated cutting needle: results in 122 patients","volume":"198","author":"Klein","year":"1996","journal-title":"Radiology"},{"key":"2024101711263073000_8.1.00562-2021.20","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1148\/radiol.2015150381","article-title":"Frequency and severity of pulmonary hemorrhage in patients undergoing percutaneous CT-guided transthoracic lung biopsy: single-institution experience of 1175 cases","volume":"279","author":"Tai","year":"2016","journal-title":"Radiology"}],"container-title":["ERJ Open Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1183\/23120541.00562-2021","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,2,24]],"date-time":"2025-02-24T00:13:18Z","timestamp":1740355998000},"score":1,"resource":{"primary":{"URL":"https:\/\/publications.ersnet.org\/lookup\/doi\/10.1183\/23120541.00562-2021"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,12,10]]},"references-count":20,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,1,24]]},"published-print":{"date-parts":[[2022,1]]}},"alternative-id":["10.1183\/23120541.00562-2021"],"URL":"https:\/\/doi.org\/10.1183\/23120541.00562-2021","relation":{},"ISSN":["2312-0541"],"issn-type":[{"value":"2312-0541","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,12,10]]}}}