{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,14]],"date-time":"2026-10-14T20:17:33Z","timestamp":1792009053287,"version":"4.4.0"},"reference-count":34,"publisher":"European Respiratory Society (ERS)","issue":"3","license":[{"start":{"date-parts":[[2025,12,11]],"date-time":"2025-12-11T00:00:00Z","timestamp":1765411200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Onera Health","award":["NA"],"award-info":[{"award-number":["NA"]}]}],"content-domain":{"domain":["publications.ersnet.org"],"crossmark-restriction":true},"short-container-title":["ERJ Open Res"],"accepted":{"date-parts":[[2025,11,26]]},"published-print":{"date-parts":[[2026,5]]},"abstract":"<jats:sec>\n                    <jats:title>Study objectives<\/jats:title>\n                    <jats:p>The Onera Sleep Test System (STS), the first wireless, patch-based, type II polysomnography (PSG) device designed to enable unattended sleep studies at the patient's home, has been introduced. This multicentre study validated data collected from the patch-based PSG against traditional PSG for the classification of sleep-related respiratory events.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and methods<\/jats:title>\n                    <jats:p>Seven clinical sites recruited 206 participants to complete a simultaneous sleep study in the sleep laboratory with a traditional PSG and a patch-based PSG system. Three independent scorers, blinded to patient and device type, evaluated the traditional PSG and patch-based PSG recordings in accordance with American Academy of Sleep Medicine (AASM) 2020 (Version 2.6) guidelines.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      The subjects were middle aged and mildly obese (50.9\u00b112.3\u2005years of age, body mass index 30.2\u00b16.2). There was strong positive correlation between the apnoea\u2013hypopnoea index ((AHI) using 3% desaturation or arousal rule) (0.90), apnoea index (0.89), central apnoea index (0.78), obstructive apnoea index (0.86), hypopnoea index (0.68) and arousal index (0.72) measured by the two devices. Differences in oxygen saturation (\n                      <jats:italic>S<\/jats:italic>\n                      <jats:sub>\n                        pO\n                        <jats:sub>2<\/jats:sub>\n                      <\/jats:sub>\n                      ) measurement were seen as a function of measurement site with the forehead measurements showing higher\n                      <jats:italic>S<\/jats:italic>\n                      <jats:sub>\n                        pO\n                        <jats:sub>2<\/jats:sub>\n                      <\/jats:sub>\n                      values. The patch-based device showed diagnostic utility (AUC \u22650.8) for AHI severity thresholds at 5, 15 and 30.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The Onera STS patch-based PSG system demonstrated reasonably good agreement with traditional PSG systems in detecting sleep-disordered breathing events and in diagnosing obstructive sleep apnoea by the AHI.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1183\/23120541.00857-2025","type":"journal-article","created":{"date-parts":[[2025,12,11]],"date-time":"2025-12-11T18:50:25Z","timestamp":1765479025000},"page":"00857-2025","update-policy":"https:\/\/doi.org\/10.1183\/ers-crossmark-policy","source":"Crossref","is-referenced-by-count":1,"title":["Clinical validation of respiratory outcomes for a patch-based polysomnography system"],"prefix":"10.1183","volume":"12","author":[{"given":"Holger","family":"Woehrle","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christian","family":"Viniol","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wolfgang","family":"Galetke","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Georg","family":"Nilius","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christoph","family":"Sch\u00f6bel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5010-8461","authenticated-orcid":false,"given":"Winfried","family":"Randerath","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James","family":"Leiter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2639-1180","authenticated-orcid":false,"given":"Sebastian","family":"Canisius","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hartmut","family":"Schneider","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"81","published-online":{"date-parts":[[2025,12,11]]},"reference":[{"key":"2026060801450625000_12.3.00857-2025.1","doi-asserted-by":"publisher","DOI":"10.5664\/jcsm.6506"},{"key":"2026060801450625000_12.3.00857-2025.2","doi-asserted-by":"crossref","unstructured":"Selvaraj N , Narasimhan R . Automated prediction of the apnea\u2013hypopnea index using a wireless patch sensor. Annu Int Conf IEEE Eng Med Biol Soc 2014; 2014: 1897\u20131900.","DOI":"10.1109\/EMBC.2014.6943981"},{"key":"2026060801450625000_12.3.00857-2025.3","doi-asserted-by":"crossref","first-page":"550","DOI":"10.1109\/JBHI.2021.3098312","article-title":"Respiratory event detection during sleep using electrocardiogram and respiratory related signals: using polysomnogram and patch-type wearable device data","volume":"26","author":"Yeo","year":"2022","journal-title":"IEEE J Biomed Health Inform"},{"key":"2026060801450625000_12.3.00857-2025.4","doi-asserted-by":"crossref","unstructured":"Viniol C , Galetke W , Woehrle H , et al. Clinical validation of a wireless patch-based polysomnography system. J Clin Sleep Med 2025; 21: 813\u2013823.","DOI":"10.5664\/jcsm.11524"},{"key":"2026060801450625000_12.3.00857-2025.5","doi-asserted-by":"crossref","first-page":"1143","DOI":"10.1111\/resp.12129","article-title":"Comparing finger and forehead sensors to measure oxygen saturation in people with chronic obstructive pulmonary disease","volume":"18","author":"Wilson","year":"2013","journal-title":"Respirology"},{"key":"2026060801450625000_12.3.00857-2025.6","doi-asserted-by":"publisher","DOI":"10.1186\/s13054-015-0984-8"},{"key":"2026060801450625000_12.3.00857-2025.7","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrtlng.2006.07.007"},{"key":"2026060801450625000_12.3.00857-2025.8","doi-asserted-by":"crossref","unstructured":"Castro I , Patel A , Deviaene M , et al. Unobtrusive, Through-Clothing ECG and Bioimpedance Monitoring in Sleep Apnea Patients. IEEE 2020 Computing in Cardiology Conference, Rimini, Italy, 2020.","DOI":"10.22489\/CinC.2020.191"},{"key":"2026060801450625000_12.3.00857-2025.9","doi-asserted-by":"publisher","DOI":"10.1152\/japplphysiol.00657.2013"},{"key":"2026060801450625000_12.3.00857-2025.10","doi-asserted-by":"crossref","first-page":"89487","DOI":"10.1109\/ACCESS.2019.2926841","article-title":"Wearable bioimpedance measurement for respiratory monitoring during inspiratory loading","volume":"7","author":"Blanco-Almazan","year":"2019","journal-title":"IEEE Access"},{"key":"2026060801450625000_12.3.00857-2025.11","unstructured":"Berry R , Quan S , Abreau A . The AASM Manual for the Scoring of Sleep and Associated Events: Rules, Terminology and Technical Specifications, Version 2.6 . Darien, IL, American Academy of Sleep Medicine, 2020."},{"key":"2026060801450625000_12.3.00857-2025.12","doi-asserted-by":"crossref","unstructured":"Kreidler SM , Muller KE , Grunwald GK , et al. GLIMMPSE: online power computation for linear models with and without a baseline covariate. J Stat Softw 2013; 54: i10. doi:10.18637\/jss.v054.i10","DOI":"10.18637\/jss.v054.i10"},{"key":"2026060801450625000_12.3.00857-2025.13","doi-asserted-by":"publisher","DOI":"10.2307\/2532051"},{"key":"2026060801450625000_12.3.00857-2025.14","doi-asserted-by":"publisher","DOI":"10.1016\/S1389-9457(01)00115-0"},{"key":"2026060801450625000_12.3.00857-2025.15","doi-asserted-by":"publisher","DOI":"10.1007\/s11325-008-0214-6"},{"key":"2026060801450625000_12.3.00857-2025.16","doi-asserted-by":"crossref","first-page":"901","DOI":"10.1093\/sleep\/23.7.1e","article-title":"Interobserver agreement among sleep scorers from different centers in a large dataset","volume":"23","author":"Norman","year":"2000","journal-title":"Sleep"},{"key":"2026060801450625000_12.3.00857-2025.17","doi-asserted-by":"crossref","first-page":"1266","DOI":"10.1016\/j.chest.2022.12.029","article-title":"Night-to-night variability of polysomnography-derived physiologic endotypic traits in patients with moderate to severe OSA","volume":"163","author":"Strassberger","year":"2023","journal-title":"Chest"},{"key":"2026060801450625000_12.3.00857-2025.18","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1080\/17476348.2025.2457370","article-title":"Night-to-night variability in obstructive sleep apnoea: when might a multi-night measurement be helpful?","volume":"19","author":"Schwarz","year":"2025","journal-title":"Expert Rev Respir Med"},{"key":"2026060801450625000_12.3.00857-2025.19","doi-asserted-by":"crossref","first-page":"629709","DOI":"10.3389\/fneur.2021.629709","article-title":"Accuracy of actigraphy compared to concomitant ambulatory polysomnography in narcolepsy and other sleep disorders","volume":"12","author":"Alakuijala","year":"2021","journal-title":"Front Neurol"},{"key":"2026060801450625000_12.3.00857-2025.20","doi-asserted-by":"crossref","first-page":"2605","DOI":"10.5664\/jcsm.10174","article-title":"A comparison of agreement between actigraphy and polysomnography for assessing sleep during posttraumatic amnesia","volume":"18","author":"Fedele","year":"2022","journal-title":"J Clin Sleep Med"},{"key":"2026060801450625000_12.3.00857-2025.21","doi-asserted-by":"crossref","first-page":"497","DOI":"10.5664\/jcsm.3694","article-title":"Validation of the apnea risk evaluation system (ARES) device against laboratory polysomnography in pregnant women at risk for obstructive sleep apnea syndrome","volume":"10","author":"Sharkey","year":"2014","journal-title":"J Clin Sleep Med"},{"key":"2026060801450625000_12.3.00857-2025.22","doi-asserted-by":"publisher","DOI":"10.1213\/ANE.0000000000002864"},{"key":"2026060801450625000_12.3.00857-2025.23","doi-asserted-by":"crossref","unstructured":"Altman DG . Practical Statistics for Medical Research. New York, Chapman and Hall\/CRC, 1990.","DOI":"10.1201\/9780429258589"},{"key":"2026060801450625000_12.3.00857-2025.24","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcm.2016.02.012"},{"key":"2026060801450625000_12.3.00857-2025.25","doi-asserted-by":"publisher","DOI":"10.4103\/tjem.tjem_182_23"},{"key":"2026060801450625000_12.3.00857-2025.26","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehy624"},{"key":"2026060801450625000_12.3.00857-2025.27","doi-asserted-by":"publisher","DOI":"10.1016\/j.bja.2024.01.023"},{"key":"2026060801450625000_12.3.00857-2025.28","doi-asserted-by":"publisher","DOI":"10.5664\/jcsm.8278"},{"key":"2026060801450625000_12.3.00857-2025.29","doi-asserted-by":"crossref","first-page":"687","DOI":"10.1016\/S2213-2600(19)30198-5","article-title":"Estimation of the global prevalence and burden of obstructive sleep apnoea: a literature-based analysis","volume":"7","author":"Benjafield A","year":"2019","journal-title":"Lancet Respir Med"},{"key":"2026060801450625000_12.3.00857-2025.30","doi-asserted-by":"publisher","DOI":"10.1016\/j.smrv.2016.07.002"},{"key":"2026060801450625000_12.3.00857-2025.31","doi-asserted-by":"crossref","first-page":"310","DOI":"10.1016\/S2213-2600(15)00043-0","article-title":"Prevalence of sleep-disordered breathing in the general population: the HypnoLaus study","volume":"3","author":"Heinzer","year":"2015","journal-title":"Lancet Respir Med"},{"key":"2026060801450625000_12.3.00857-2025.32","unstructured":"Faizullabhoy M , Wani G . Sleep Study Market \u2013 Testing Services (In-Lab Testing, Home Sleep Testing), Indication (Obstructive Sleep Apnea, Insomnia, Restless Leg Syndrome, Circadian Rhythm Sleeping Disorders, Narcolepsy, Bruxism), End-user \u2013 Global Forecast (2024\u20132032). 2024. www.gminsights.com\/industry-analysis\/sleep-study-market"},{"key":"2026060801450625000_12.3.00857-2025.33","doi-asserted-by":"publisher","DOI":"10.1093\/sleep\/20.12.1077"},{"key":"2026060801450625000_12.3.00857-2025.34","doi-asserted-by":"crossref","unstructured":"Ferretti D , Islind AS , \u00d3lafsd\u00f3ttir KA , et al. Feasibility and usability of three consecutive nights with self-applied, home polysomnography. J Sleep Res 2025; 34: e14286. doi:10.1111\/jsr.14286","DOI":"10.1111\/jsr.14286"}],"container-title":["ERJ Open Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1183\/23120541.00857-2025","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,8]],"date-time":"2026-06-08T08:45:29Z","timestamp":1780908329000},"score":1,"resource":{"primary":{"URL":"https:\/\/publications.ersnet.org\/lookup\/doi\/10.1183\/23120541.00857-2025"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12,11]]},"references-count":34,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2026,6,8]]},"published-print":{"date-parts":[[2026,5]]}},"alternative-id":["10.1183\/23120541.00857-2025"],"URL":"https:\/\/doi.org\/10.1183\/23120541.00857-2025","relation":{},"ISSN":["2312-0541"],"issn-type":[{"value":"2312-0541","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,12,11]]}}}