{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,9]],"date-time":"2026-03-09T17:38:14Z","timestamp":1773077894297,"version":"3.50.1"},"reference-count":43,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2009,5,17]],"date-time":"2009-05-17T00:00:00Z","timestamp":1242518400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Emerg Med"],"published-print":{"date-parts":[[2009,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>Intubation of the trachea in the pre-hospital setting may be lifesaving in severely ill and injured patients. However, tracheal intubation is frequently difficult to perform in this challenging environment, is associated with a lower success rate, and failed tracheal intubation constitutes an important cause of morbidity. Novel indirect laryngoscopes, such as the Glidescope<jats:sup>\u00ae<\/jats:sup> and the AWS<jats:sup>\u00ae<\/jats:sup> laryngoscopes may reduce this risk.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>We compared the efficacy of these devices to the Macintosh laryngoscope when used by 25 Advanced Paramedics proficient in direct laryngoscopy, in a randomized, controlled, manikin study. Following brief didactic instruction with the Glidescope<jats:sup>\u00ae<\/jats:sup> and the AWS<jats:sup>\u00ae<\/jats:sup> laryngoscopes, each participant took turns performing laryngoscopy and intubation with each device, in an easy intubation scenario and following placement of a hard cervical collar, in a SimMan<jats:sup>\u00ae<\/jats:sup> manikin.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>Both the Glidescope<jats:sup>\u00ae<\/jats:sup> and the AWS<jats:sup>\u00ae<\/jats:sup> performed better than the Macintosh, and demonstrate considerable promise in this context. The AWS<jats:sup>\u00ae<\/jats:sup> had the least number of dental compressions in all three scenarios, and in the cervical spine immobilization scenario it required fewer maneuvers to optimize the view of the glottis.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion<\/jats:title>\n            <jats:p>The Glidescope<jats:sup>\u00ae<\/jats:sup> and AWS<jats:sup>\u00ae<\/jats:sup> devices possess advantages over the conventional Macintosh laryngoscope when used by Advanced Paramedics in normal and simulated difficult intubation scenarios in this manikin study. Further studies are required to extend these findings to the clinical setting.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1186\/1471-227x-9-9","type":"journal-article","created":{"date-parts":[[2009,5,19]],"date-time":"2009-05-19T07:26:00Z","timestamp":1242717960000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":49,"title":["Comparison of the Glidescope\u00ae and Pentax AWS\u00aelaryngoscopes to the Macintosh laryngoscope for use by Advanced Paramedics in easy and simulated difficult intubation"],"prefix":"10.1186","volume":"9","author":[{"given":"Sajid","family":"Nasim","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chrisen H","family":"Maharaj","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Muhammad A","family":"Malik","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"John","family":"O' Donnell","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Brendan D","family":"Higgins","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"John G","family":"Laffey","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2009,5,17]]},"reference":[{"issue":"6","key":"78_CR1","doi-asserted-by":"publisher","first-page":"592","DOI":"10.1001\/archsurg.1997.01430300034007","volume":"132","author":"RJ Winchell","year":"1997","unstructured":"Winchell RJ, Hoyt DB: Endotracheal intubation in the field improves survival in patients with severe head injury. Trauma Research and Education Foundation of San Diego. Arch Surg. 1997, 132 (6): 592-597.","journal-title":"Arch Surg"},{"issue":"10","key":"78_CR2","doi-asserted-by":"publisher","first-page":"697","DOI":"10.1046\/j.1440-1622.1999.01688.x","volume":"69","author":"A Garner","year":"1999","unstructured":"Garner A, Rashford S, Lee A, Bartolacci R: Addition of physicians to paramedic helicopter services decreases blunt trauma mortality. Aust N Z J Surg. 1999, 69 (10): 697-701. 10.1046\/j.1440-1622.1999.01688.x.","journal-title":"Aust N Z J Surg"},{"issue":"4","key":"78_CR3","doi-asserted-by":"publisher","first-page":"285","DOI":"10.1097\/00063110-199912000-00002","volume":"6","author":"G Sanson","year":"1999","unstructured":"Sanson G, Di Bartolomeo S, Nardi G, Albanese P, Diani A, Raffin L, Filippetto C, Cattarossi A, Scian E, Rizzi L: Road traffic accidents with vehicular entrapment: incidence of major injuries and need for advanced life support. Eur J Emerg Med. 1999, 6 (4): 285-291.","journal-title":"Eur J Emerg Med"},{"issue":"4","key":"78_CR4","doi-asserted-by":"publisher","first-page":"255","DOI":"10.1016\/j.jclinane.2005.02.004","volume":"17","author":"TC Mort","year":"2005","unstructured":"Mort TC: Esophageal intubation with indirect clinical tests during emergency tracheal intubation: a report on patient morbidity. J Clin Anesth. 2005, 17 (4): 255-262. 10.1016\/j.jclinane.2005.02.004.","journal-title":"J Clin Anesth"},{"issue":"2","key":"78_CR5","doi-asserted-by":"publisher","first-page":"607","DOI":"10.1213\/01.ANE.0000122825.04923.15","volume":"99","author":"TC Mort","year":"2004","unstructured":"Mort TC: Emergency tracheal intubation: complications associated with repeated laryngoscopic attempts. Anesth Analg. 2004, 99 (2): 607-613. 10.1213\/01.ANE.0000122825.04923.15. table of contents.","journal-title":"Anesth Analg"},{"issue":"5","key":"78_CR6","doi-asserted-by":"publisher","first-page":"705","DOI":"10.1093\/bja\/aeg560","volume":"90","author":"F Agro","year":"2003","unstructured":"Agro F, Barzoi G, Montecchia F: Tracheal intubation using a Macintosh laryngoscope or a GlideScope in 15 patients with cervical spine immobilization. Br J Anaesth. 2003, 90 (5): 705-706. 10.1093\/bja\/aeg560.","journal-title":"Br J Anaesth"},{"issue":"3","key":"78_CR7","doi-asserted-by":"publisher","first-page":"381","DOI":"10.1093\/bja\/aei041","volume":"94","author":"DA Sun","year":"2005","unstructured":"Sun DA, Warriner CB, Parsons DG, Klein R, Umedaly HS, Moult M: The GlideScope Video Laryngoscope: randomized clinical trial in 200 patients. Br J Anaesth. 2005, 94 (3): 381-384. 10.1093\/bja\/aei041.","journal-title":"Br J Anaesth"},{"issue":"5","key":"78_CR8","doi-asserted-by":"publisher","first-page":"723","DOI":"10.1093\/bja\/aen231","volume":"101","author":"MA Malik","year":"2008","unstructured":"Malik MA, Maharaj CH, Harte BH, Laffey JG: Comparison of Macintosh, Truview EVO2, Glidescope, and Airwayscope laryngoscope use in patients with cervical spine immobilization. Br J Anaesth. 2008, 101 (5): 723-730. 10.1093\/bja\/aen231.","journal-title":"Br J Anaesth"},{"issue":"2","key":"78_CR9","doi-asserted-by":"publisher","first-page":"191","DOI":"10.1007\/BF03027728","volume":"52","author":"RM Cooper","year":"2005","unstructured":"Cooper RM, Pacey JA, Bishop MJ, McCluskey SA: Early clinical experience with a new videolaryngoscope (GlideScope) in 728 patients. Can J Anaesth. 2005, 52 (2): 191-198. 10.1007\/BF03027728.","journal-title":"Can J Anaesth"},{"issue":"4","key":"78_CR10","doi-asserted-by":"publisher","first-page":"544","DOI":"10.1093\/bja\/aen002","volume":"100","author":"Y Enomoto","year":"2008","unstructured":"Enomoto Y, Asai T, Arai T, Kamishima K, Okuda Y: Pentax-AWS, a new videolaryngoscope, is more effective than the Macintosh laryngoscope for tracheal intubation in patients with restricted neck movements: a randomized comparative study. Br J Anaesth. 2008, 100 (4): 544-548. 10.1093\/bja\/aen002.","journal-title":"Br J Anaesth"},{"issue":"1","key":"78_CR11","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1097\/01.anes.0000267529.71756.f0","volume":"107","author":"CH Maharaj","year":"2007","unstructured":"Maharaj CH, Buckley E, Harte BH, Laffey JG: Endotracheal Intubation in Patients with Cervical Spine Immobilization: A Comparison of Macintosh and Airtraq\u2122 Laryngoscopes. Anesthesiology. 2007, 107 (1): 53-59. 10.1097\/01.anes.0000267529.71756.f0.","journal-title":"Anesthesiology"},{"issue":"2","key":"78_CR12","doi-asserted-by":"publisher","first-page":"182","DOI":"10.1111\/j.1365-2044.2007.05316.x","volume":"63","author":"CH Maharaj","year":"2008","unstructured":"Maharaj CH, Costello JF, Harte BH, Laffey JG: Evaluation of the Airtraq and Macintosh laryngoscopes in patients at increased risk for difficult tracheal intubation. Anaesthesia. 2008, 63 (2): 182-188.","journal-title":"Anaesthesia"},{"issue":"11","key":"78_CR13","doi-asserted-by":"publisher","first-page":"1093","DOI":"10.1111\/j.1365-2044.2006.04819.x","volume":"61","author":"CH Maharaj","year":"2006","unstructured":"Maharaj CH, O'Croinin D, Curley G, Harte BH, Laffey JG: A comparison of tracheal intubation using the Airtraq or the Macintosh laryngoscope in routine airway management: a randomised, controlled clinical trial. Anaesthesia. 2006, 61 (11): 1093-1099. 10.1111\/j.1365-2044.2006.04819.x.","journal-title":"Anaesthesia"},{"issue":"5","key":"78_CR14","doi-asserted-by":"publisher","first-page":"654","DOI":"10.1093\/bja\/aep056","volume":"102","author":"MA Malik","year":"2009","unstructured":"Malik MA, Subramaniam R, Churasia S, Maharaj CH, Harte BH, Laffey JG: Tracheal intubation in patients with cervical spine immobilization: a comparison of the Airwayscope, LMA CTrach, and the Macintosh laryngoscopes. Br J Anaesth. 2009, 102 (5): 654-661. 10.1093\/bja\/aep056.","journal-title":"Br J Anaesth"},{"issue":"5","key":"78_CR15","doi-asserted-by":"publisher","first-page":"469","DOI":"10.1111\/j.1365-2044.2006.04547.x","volume":"61","author":"CH Maharaj","year":"2006","unstructured":"Maharaj CH, Higgins B, Harte BH, Laffey JG: Evaluation of ease of intubation with the Airtraq\u00ae or Macintosh laryngoscope by anaesthetists in easy and simulated difficult laryngoscopy \u2013 A manikin study. Anaesthesia. 2006, 61 (5): 469-477. 10.1111\/j.1365-2044.2006.04547.x.","journal-title":"Anaesthesia"},{"key":"78_CR16","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1186\/1471-227X-9-2","volume":"9","author":"S Nasim","year":"2009","unstructured":"Nasim S, Maharaj CH, Butt I, Malik MA, J OD, Higgins BD, Harte BH, Laffey JG: Comparison of the Airtraq and Truview laryngoscopes to the Macintosh laryngoscope for use by Advanced Paramedics in easy and simulated difficult intubation in manikins. BMC Emerg Med. 2009, 9: 2-10.1186\/1471-227X-9-2.","journal-title":"BMC Emerg Med"},{"issue":"7","key":"78_CR17","doi-asserted-by":"publisher","first-page":"671","DOI":"10.1111\/j.1365-2044.2006.04653.x","volume":"61","author":"CH Maharaj","year":"2006","unstructured":"Maharaj CH, Costello J, Higgins B, Harte BH, Laffey JG: Learning and performance of Tracheal intubation by novice personnel: A comparison of the Airtraq\u00ae and Macintosh laryngoscope. Anaesthesia. 2006, 61 (7): 671-677. 10.1111\/j.1365-2044.2006.04653.x.","journal-title":"Anaesthesia"},{"issue":"3","key":"78_CR18","doi-asserted-by":"publisher","first-page":"272","DOI":"10.1111\/j.1365-2044.2007.04938.x","volume":"62","author":"CH Maharaj","year":"2007","unstructured":"Maharaj CH, Costello J, Higgins BD, Harte BH, Laffey JG: Retention of tracheal intubation skills by novice personnel: A comparison of the Airtraq\u00ae and Macintosh laryngoscopes. Anaesthesia. 2007, 62 (3): 272-278. 10.1111\/j.1365-2044.2007.04938.x.","journal-title":"Anaesthesia"},{"issue":"11","key":"78_CR19","doi-asserted-by":"publisher","first-page":"1161","DOI":"10.1111\/j.1365-2044.2007.05216.x","volume":"62","author":"CH Maharaj","year":"2007","unstructured":"Maharaj CH, McDonnell JG, Harte BH, Laffey JG: A comparison of direct and indirect laryngoscopes and the ILMA in novice users: a manikin study. Anaesthesia. 2007, 62 (11): 1161-1166. 10.1111\/j.1365-2044.2007.05216.x.","journal-title":"Anaesthesia"},{"issue":"7","key":"78_CR20","doi-asserted-by":"publisher","first-page":"769","DOI":"10.1016\/j.ajem.2006.03.014","volume":"24","author":"CH Maharaj","year":"2006","unstructured":"Maharaj CH, Ni Chonghaile M, Higgins B, Harte BH, Laffey JG: Tracheal intubation by inexperienced medical residents using the Airtraq\u00ae and Macintosh laryngoscope \u2013 A manikin study. Am J Emerg Med. 2006, 24 (7): 769-774. 10.1016\/j.ajem.2006.03.014.","journal-title":"Am J Emerg Med"},{"issue":"2","key":"78_CR21","doi-asserted-by":"publisher","first-page":"301","DOI":"10.1016\/j.resuscitation.2005.06.021","volume":"68","author":"P Schlossmacher","year":"2006","unstructured":"Schlossmacher P, Martinet O, Testud R, Agesilas F, Benhamou L, Gauzere BA: Emergency percutaneous tracheostomy in a severely burned patient with upper airway obstruction and circulatory arrest. Resuscitation. 2006, 68 (2): 301-305. 10.1016\/j.resuscitation.2005.06.021.","journal-title":"Resuscitation"},{"issue":"4","key":"78_CR22","doi-asserted-by":"publisher","first-page":"454","DOI":"10.1016\/S0196-0644(98)70175-1","volume":"32","author":"F Adnet","year":"1998","unstructured":"Adnet F, Jouriles NJ, Le Toumelin P, Hennequin B, Taillandier C, Rayeh F, Couvreur J, Nougiere B, Nadiras P, Ladka A, et al: Survey of out-of-hospital emergency intubations in the French prehospital medical system: a multicenter study. Ann Emerg Med. 1998, 32 (4): 454-460. 10.1016\/S0196-0644(98)70175-1.","journal-title":"Ann Emerg Med"},{"issue":"1","key":"78_CR23","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1007\/s00101-005-0873-7","volume":"55","author":"S Koscielny","year":"2005","unstructured":"Koscielny S, Gottschall R: [Perforation of the hypopharynx as a rare life-threatening complication of endotracheal intubation]. Anaesthesist. 2005, 55 (1): 45-52. 10.1007\/s00101-005-0873-7.","journal-title":"Anaesthesist"},{"issue":"1","key":"78_CR24","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1186\/cc2420","volume":"8","author":"AM Brambrink","year":"2004","unstructured":"Brambrink AM, Koerner IP: Prehospital advanced trauma life support: how should we manage the airway, and who should do it?. Crit Care. 2004, 8 (1): 3-5. 10.1186\/cc2420.","journal-title":"Crit Care"},{"issue":"6","key":"78_CR25","doi-asserted-by":"publisher","first-page":"413","DOI":"10.1097\/00075198-200112000-00008","volume":"7","author":"JD Nolan","year":"2001","unstructured":"Nolan JD: Prehospital and resuscitative airway care: should the gold standard be reassessed?. Curr Opin Crit Care. 2001, 7 (6): 413-421. 10.1097\/00075198-200112000-00008.","journal-title":"Curr Opin Crit Care"},{"issue":"8","key":"78_CR26","doi-asserted-by":"publisher","first-page":"1864","DOI":"10.1097\/01.CCM.0000174493.45348.94","volume":"33","author":"P Gerbeaux","year":"2005","unstructured":"Gerbeaux P: Should emergency medical service rescuers be trained to practice endotracheal intubation?. Crit Care Med. 2005, 33 (8): 1864-1865. 10.1097\/01.CCM.0000174493.45348.94.","journal-title":"Crit Care Med"},{"issue":"2","key":"78_CR27","doi-asserted-by":"publisher","first-page":"156","DOI":"10.1080\/10903120590924645","volume":"9","author":"HE Wang","year":"2005","unstructured":"Wang HE, Seitz SR, Hostler D, Yealy DM: Defining the learning curve for paramedic student endotracheal intubation. Prehosp Emerg Care. 2005, 9 (2): 156-162. 10.1080\/10903120590924645.","journal-title":"Prehosp Emerg Care"},{"issue":"3","key":"78_CR28","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1016\/S0736-4679(03)00198-7","volume":"25","author":"AG Garza","year":"2003","unstructured":"Garza AG, Gratton MC, Coontz D, Noble E, Ma OJ: Effect of paramedic experience on orotracheal intubation success rates. J Emerg Med. 2003, 25 (3): 251-256. 10.1016\/S0736-4679(03)00198-7.","journal-title":"J Emerg Med"},{"issue":"1","key":"78_CR29","doi-asserted-by":"publisher","first-page":"64","DOI":"10.1136\/emj.2004.017178","volume":"22","author":"CD Deakin","year":"2005","unstructured":"Deakin CD, Peters R, Tomlinson P, Cassidy M: Securing the prehospital airway: a comparison of laryngeal mask insertion and endotracheal intubation by UK paramedics. Emerg Med J. 2005, 22 (1): 64-67. 10.1136\/emj.2004.017178.","journal-title":"Emerg Med J"},{"issue":"2","key":"78_CR30","doi-asserted-by":"publisher","first-page":"149","DOI":"10.1016\/j.resuscitation.2004.01.014","volume":"61","author":"J Kurola","year":"2004","unstructured":"Kurola J, Harve H, Kettunen T, Laakso JP, Gorski J, Paakkonen H, Silfvast T: Airway management in cardiac arrest \u2013 comparison of the laryngeal tube, tracheal intubation and bag-valve mask ventilation in emergency medical training. Resuscitation. 2004, 61 (2): 149-153. 10.1016\/j.resuscitation.2004.01.014.","journal-title":"Resuscitation"},{"issue":"1","key":"78_CR31","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1080\/312703002764","volume":"8","author":"C Rumball","year":"2004","unstructured":"Rumball C, Macdonald D, Barber P, Wong H, Smecher C: Endotracheal intubation and esophageal tracheal Combitube insertion by regular ambulance attendants: a comparative trial. Prehosp Emerg Care. 2004, 8 (1): 15-22.","journal-title":"Prehosp Emerg Care"},{"issue":"5","key":"78_CR32","doi-asserted-by":"publisher","first-page":"337","DOI":"10.1017\/S0265021505000578","volume":"22","author":"N Weksler","year":"2005","unstructured":"Weksler N, Tarnopolski A, Klein M, Schily M, Rozentsveig V, Shapira AR, Gurman GM: Insertion of the endotracheal tube, laryngeal mask airway and oesophageal-tracheal Combitube. A 6-month comparative prospective study of acquisition and retention skills by medical students. Eur J Anaesthesiol. 2005, 22 (5): 337-340. 10.1017\/S0265021505000578.","journal-title":"Eur J Anaesthesiol"},{"issue":"5\u20136","key":"78_CR33","doi-asserted-by":"publisher","first-page":"459","DOI":"10.1046\/j.1442-2026.2003.00502.x","volume":"15","author":"VM Vertongen","year":"2003","unstructured":"Vertongen VM, Ramsay MP, Herbison P: Skills retention for insertion of the Combitube and laryngeal mask airway. Emerg Med (Fremantle). 2003, 15 (5\u20136): 459-464.","journal-title":"Emerg Med (Fremantle)"},{"issue":"1","key":"78_CR34","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1097\/00000542-200301000-00007","volume":"98","author":"JT Mulcaster","year":"2003","unstructured":"Mulcaster JT, Mills J, Hung OR, MacQuarrie K, Law JA, Pytka S, Imrie D, Field C: Laryngoscopic intubation: learning and performance. Anesthesiology. 2003, 98 (1): 23-27. 10.1097\/00000542-200301000-00007.","journal-title":"Anesthesiology"},{"issue":"4","key":"78_CR35","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1097\/00008506-200610000-00005","volume":"18","author":"J Koyama","year":"2006","unstructured":"Koyama J, Aoyama T, Kusano Y, Seguchi T, Kawagishi K, Iwashita T, Okamoto K, Okudera H, Takasuna H, Hongo K: Description and first clinical application of AirWay Scope for tracheal intubation. J Neurosurg Anesthesiol. 2006, 18 (4): 247-250. 10.1097\/00008506-200610000-00005.","journal-title":"J Neurosurg Anesthesiol"},{"issue":"9","key":"78_CR36","doi-asserted-by":"publisher","first-page":"936","DOI":"10.1111\/j.1365-2044.2007.05152.x","volume":"62","author":"Y Koyama","year":"2007","unstructured":"Koyama Y, Inagawa G, Miyashita T, Kikuchi T, Miura N, Miki T, Kurihara R, Kamiya Y, Goto T: Comparison of the Airway Scope, gum elastic bougie and fibreoptic bronchoscope in simulated difficult tracheal intubation: a manikin study. Anaesthesia. 2007, 62 (9): 936-939. 10.1111\/j.1365-2044.2007.05152.x.","journal-title":"Anaesthesia"},{"issue":"10","key":"78_CR37","doi-asserted-by":"publisher","first-page":"1378","DOI":"10.1111\/j.1399-6576.2007.01450.x","volume":"51","author":"T Miki","year":"2007","unstructured":"Miki T, Inagawa G, Kikuchi T, Koyama Y, Goto T: Evaluation of the Airway Scope, a new video laryngoscope, in tracheal intubation by naive operators: a manikin study. Acta Anaesthesiol Scand. 2007, 51 (10): 1378-1381.","journal-title":"Acta Anaesthesiol Scand"},{"issue":"2","key":"78_CR38","doi-asserted-by":"publisher","first-page":"160","DOI":"10.1007\/BF03022021","volume":"54","author":"Y Hirabayashi","year":"2007","unstructured":"Hirabayashi Y: Airway Scope: initial clinical experience with novice personnel. Can J Anaesth. 2007, 54 (2): 160-161. 10.1007\/BF03022021.","journal-title":"Can J Anaesth"},{"issue":"7","key":"78_CR39","doi-asserted-by":"publisher","first-page":"671","DOI":"10.1111\/j.1365-2044.2006.04653.x","volume":"61","author":"CH Maharaj","year":"2006","unstructured":"Maharaj CH, Costello JF, Higgins BD, Harte BH, Laffey JG: Learning and performance of tracheal intubation by novice personnel: a comparison of the Airtraq and Macintosh laryngoscope. Anaesthesia. 2006, 61 (7): 671-677. 10.1111\/j.1365-2044.2006.04653.x.","journal-title":"Anaesthesia"},{"issue":"6","key":"78_CR40","doi-asserted-by":"publisher","first-page":"598","DOI":"10.1111\/j.1365-2044.2007.05036.x","volume":"62","author":"CH Maharaj","year":"2007","unstructured":"Maharaj CH, Costello JF, McDonnell JG, Harte BH, Laffey JG: The Airtraq as a rescue airway device following failed direct laryngoscopy: A case series. Anaesthesia. 2007, 62 (6): 598-601. 10.1111\/j.1365-2044.2007.05036.x.","journal-title":"Anaesthesia"},{"issue":"6","key":"78_CR41","doi-asserted-by":"publisher","first-page":"674","DOI":"10.1007\/BF03015455","volume":"44","author":"T Uchida","year":"1997","unstructured":"Uchida T, Hikawa Y, Saito Y, Yasuda K: The McCoy levering laryngoscope in patients with limited neck extension. Can J Anaesth. 1997, 44 (6): 674-676. 10.1007\/BF03015455.","journal-title":"Can J Anaesth"},{"issue":"1","key":"78_CR42","doi-asserted-by":"publisher","first-page":"128","DOI":"10.1093\/bja\/aen342","volume":"102","author":"MA Malik","year":"2009","unstructured":"Malik MA, O'Donoghue C, Carney J, Maharaj CH, Harte BH, Laffey JG: Comparison of the Glidescope, the Pentax AWS, and the Truview EVO2 with the Macintosh laryngoscope in experienced anaesthetists: a manikin study. Br J Anaesth. 2009, 102 (1): 128-134. 10.1093\/bja\/aen342.","journal-title":"Br J Anaesth"},{"issue":"7","key":"78_CR43","doi-asserted-by":"publisher","first-page":"668","DOI":"10.1111\/j.1365-2044.2005.04224.x","volume":"60","author":"C Rudolph","year":"2005","unstructured":"Rudolph C, Schneider JP, Wallenborn J, Schaffranietz L: Movement of the upper cervical spine during laryngoscopy: a comparison of the Bonfils intubation fibrescope and the Macintosh laryngoscope. Anaesthesia. 2005, 60 (7): 668-672. 10.1111\/j.1365-2044.2005.04224.x.","journal-title":"Anaesthesia"}],"container-title":["BMC Emergency Medicine"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/1471-227X-9-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/1471-227X-9-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/1471-227X-9-9","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/1471-227X-9-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,8,31]],"date-time":"2021-08-31T21:30:34Z","timestamp":1630445434000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcemergmed.biomedcentral.com\/articles\/10.1186\/1471-227X-9-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,5,17]]},"references-count":43,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2009,12]]}},"alternative-id":["78"],"URL":"https:\/\/doi.org\/10.1186\/1471-227x-9-9","relation":{},"ISSN":["1471-227X"],"issn-type":[{"value":"1471-227X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,5,17]]},"assertion":[{"value":"9 February 2009","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 May 2009","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 May 2009","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}],"article-number":"9"}}