{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,25]],"date-time":"2026-02-25T21:17:03Z","timestamp":1772054223018,"version":"3.50.1"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2010,5,21]],"date-time":"2010-05-21T00:00:00Z","timestamp":1274400000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Med Imaging"],"published-print":{"date-parts":[[2010,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Background<\/jats:title><jats:p>A widespread and fundamental assumption in the health sciences is that muscle functions are related to a wide variety of conditions, for example pain, ischemic and neurological disorder, exercise and injury. It is therefore highly desirable to study musculoskeletal contributions in clinical applications such as the treatment of muscle injuries, post-surgery evaluations, monitoring of progressive degeneration in neuromuscular disorders, and so on.<\/jats:p><jats:p>The spatial image resolution in ultrasound systems has improved tremendously in the last few years and nowadays provides detailed information about tissue characteristics. It is now possible to study skeletal muscles in real-time during activity.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>The ultrasound images are transformed to be congruent and are effectively compressed and stacked in order to be analysed with multivariate techniques. The method is applied to a relevant clinical orthopaedic research field, namely to describe the dynamics in the Achilles tendon and the calf during real-time movements.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>This study introduces a novel method to medical applications that can be used to examine ultrasound image sequences and to detect, visualise and quantify skeletal muscle dynamics and functions.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>This new objective method is a powerful tool to use when visualising tissue activity and dynamics of musculoskeletal ultrasound registrations.<\/jats:p><\/jats:sec>","DOI":"10.1186\/1471-2342-10-9","type":"journal-article","created":{"date-parts":[[2010,6,17]],"date-time":"2010-06-17T18:15:35Z","timestamp":1276798535000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":18,"title":["Modelling human musculoskeletal functional movements using ultrasound imaging"],"prefix":"10.1186","volume":"10","author":[{"given":"Michael","family":"Peolsson","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tommy","family":"L\u00f6fstedt","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Susanna","family":"Vogt","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hans","family":"Stenlund","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anton","family":"Arndt","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Johan","family":"Trygg","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2010,5,21]]},"reference":[{"key":"86_CR1","doi-asserted-by":"publisher","first-page":"530","DOI":"10.1097\/BOR.0b013e3282efdc66","volume":"19","author":"GP Kuo","year":"2007","unstructured":"Kuo GP, Carrino JA: Skeletal muscle imaging and inflammatory myopathies. Current opinion in rheumatology. 2007, 19: 530-535. 10.1097\/BOR.0b013e3282efdc66.","journal-title":"Current opinion in rheumatology"},{"key":"86_CR2","doi-asserted-by":"publisher","first-page":"137","DOI":"10.1016\/j.ejpain.2005.02.001","volume":"10","author":"A Elvin","year":"2006","unstructured":"Elvin A, Si\u00f6steen AK, Nilsson A, Kosek E: Decreased muscle blood flow in fibromyalgia patients during standardised muscle exercise: A contrast media enhanced colour doppler study. European Journal of Pain. 2006, 10: 137-144. 10.1016\/j.ejpain.2005.02.001.","journal-title":"European Journal of Pain"},{"key":"86_CR3","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1111\/j.1600-0838.2006.00545.x","volume":"17","author":"J N\u00f8rregaard","year":"2007","unstructured":"N\u00f8rregaard J, Larsen CC, Bieler T, Langberg H: Eccentric exercise in treatment of Achilles tendinopathy. Scandinavian journal of medicine & science in sports. 2007, 17: 133-138.","journal-title":"Scandinavian journal of medicine & science in sports"},{"key":"86_CR4","doi-asserted-by":"publisher","first-page":"813","DOI":"10.1016\/j.berh.2004.05.001","volume":"18","author":"W Grassi","year":"2004","unstructured":"Grassi W, Filippucci E, Busilacchi P: Musculoskeletal ultrasound. Best Practice & Research Clinical Rheumatology. 2004, 18: 813-826.","journal-title":"Best Practice & Research Clinical Rheumatology"},{"key":"86_CR5","doi-asserted-by":"publisher","first-page":"823","DOI":"10.1093\/rheumatology\/keh214","volume":"43","author":"D Kane","year":"2004","unstructured":"Kane D, Balint PV, Sturrock R, Grassi W: Musculoskeletal ultrasound - a state of the art review in rheumatology. Part 1: Current controversies and issues in the development of musculoskeletal ultrasound in rheumatology. Rheumatology. 2004, 43: 823-828. 10.1093\/rheumatology\/keh214.","journal-title":"Rheumatology"},{"key":"86_CR6","doi-asserted-by":"publisher","first-page":"280","DOI":"10.1109\/10.133210","volume":"38","author":"LN Bohs","year":"1991","unstructured":"Bohs LN, Trahey GE: A novel method for angle independent ultrasonic imaging of blood flow and tissue motion. IEEE Transactions on Biomedical Engineering. 1991, 38: 280-286. 10.1109\/10.133210.","journal-title":"IEEE Transactions on Biomedical Engineering"},{"key":"86_CR7","doi-asserted-by":"publisher","first-page":"2177","DOI":"10.1109\/TUFFC.917","volume":"55","author":"T Deffieux","year":"2008","unstructured":"Deffieux T, Gennisson JL, Tanter M, Fink M: Assessment of the mechanical properties of the musculoskeletal system using 2-D and 3-D very high frame rate ultrasound. IEEE Trans Ultrason Ferroelectr Freq Control. 2008, 55: 2177-2190. 10.1109\/TUFFC.917.","journal-title":"IEEE Trans Ultrason Ferroelectr Freq Control"},{"key":"86_CR8","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1063\/1.2378616","volume":"89","author":"T Deffieux","year":"2006","unstructured":"Deffieux T, Gennisson JL, Tanter M, Fink M, Nordez A: Ultrafast imaging of in vivo muscle contraction using ultrasound. Applied Physics Letters. 2006, 89: 3-10.1063\/1.2378616.","journal-title":"Applied Physics Letters"},{"key":"86_CR9","doi-asserted-by":"publisher","first-page":"1970","DOI":"10.1152\/japplphysiol.00221.2009","volume":"106","author":"A Nordez","year":"2009","unstructured":"Nordez A, Gallot T, Catheline S, Guevel A, Cornu C, Hug F: Electromechanical delay revisited using very high frame rate ultrasound. J Appl Physiol. 2009, 106: 1970-1975. 10.1152\/japplphysiol.00221.2009.","journal-title":"J Appl Physiol"},{"key":"86_CR10","doi-asserted-by":"publisher","first-page":"755","DOI":"10.1109\/TMI.2005.848331","volume":"24","author":"J Revell","year":"2005","unstructured":"Revell J, Mirmehdi M, McNally D: Computer vision elastography: Speckle adaptive motion estimation for elastography using ultrasound sequences. IEEE Trans Med Imaging. 2005, 24: 755-766. 10.1109\/TMI.2005.848331.","journal-title":"IEEE Trans Med Imaging"},{"key":"86_CR11","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1109\/TUFFC.2009.1002","volume":"56","author":"J Farron","year":"2009","unstructured":"Farron J, Varghese T, Thelen DG: Measurement of tendon strain during muscle twitch contractions using ultrasound elastography. IEEE Trans Ultrason Ferroelectr Freq Control. 2009, 56: 27-35. 10.1109\/TUFFC.2009.1002.","journal-title":"IEEE Trans Ultrason Ferroelectr Freq Control"},{"key":"86_CR12","doi-asserted-by":"publisher","first-page":"2031","DOI":"10.1016\/j.ultrasmedbio.2009.06.1101","volume":"35","author":"RGP Lopata","year":"2009","unstructured":"Lopata RGP, Nillesen MM, Hansen HHG, Gerrits IH, Thijssen JM, de Korte CL: Performance of two dimensional displacement and strain estimation techniques using a phased array transducer. Ultrasound in Medicine & Biology. 2009, 35: 2031-2041.","journal-title":"Ultrasound in Medicine & Biology"},{"key":"86_CR13","doi-asserted-by":"publisher","first-page":"764","DOI":"10.1109\/ULTSYM.2004.1417834","volume-title":"2004 IEEE Ultrasonics Symposium","author":"RS Witte","year":"2004","unstructured":"Witte RS, Dow DE, Olafsson R, Shi Y, O'Donnell M: High resolution ultrasound imaging of skeletal muscle dynamics and effects of fatigue. 2004 IEEE Ultrasonics Symposium. Edited by: Yuhas MP. 2004, New York: Ieee, 1-3: 764-767. full_text. Ultrasonics Symposium"},{"key":"86_CR14","doi-asserted-by":"publisher","DOI":"10.1109\/IEMBS.2006.260850","volume-title":"Effect of fatigue on muscle elasticity in the human forearm using ultrasound strain imaging","author":"RS Witte","year":"2006","unstructured":"Witte RS, Kim K, Martin BJ, O'Donnell M: Effect of fatigue on muscle elasticity in the human forearm using ultrasound strain imaging. 2006, New York: IEEE"},{"key":"86_CR15","volume-title":"Digital Image Processing","author":"RC Gonzalez","year":"2002","unstructured":"Gonzalez RC, Woods RE: Digital Image Processing. 2002, Prentice Hall, Second","edition":"Second"},{"key":"86_CR16","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1016\/0169-7439(89)80112-1","volume":"7","author":"K Esbensen","year":"1989","unstructured":"Esbensen K, Geladi P: Strategy of multivariate image analysis (MIA). Chemometrics Intell Lab Syst. 1989, 7: 67-86. 10.1016\/0169-7439(89)80112-1.","journal-title":"Chemometrics Intell Lab Syst"},{"key":"86_CR17","doi-asserted-by":"publisher","first-page":"375","DOI":"10.1016\/0169-7439(92)80119-O","volume":"14","author":"P Geladi","year":"1992","unstructured":"Geladi P: Some special topics in multivariate image analysis. Chemometrics Intell Lab Syst. 1992, 14: 375-390. 10.1016\/0169-7439(92)80119-O.","journal-title":"Chemometrics Intell Lab Syst"},{"key":"86_CR18","doi-asserted-by":"publisher","first-page":"209","DOI":"10.1016\/0169-7439(89)80049-8","volume":"5","author":"P Geladi","year":"1989","unstructured":"Geladi P, Isaksson H, Lindqvist L, Wold S, Esbensen K: Principal component analysis of multivariate images. Chemometrics Intell Lab Syst. 1989, 5: 209-220. 10.1016\/0169-7439(89)80049-8.","journal-title":"Chemometrics Intell Lab Syst"},{"key":"86_CR19","doi-asserted-by":"publisher","first-page":"1247","DOI":"10.1016\/j.echo.2005.03.024","volume":"18","author":"J Korinek","year":"2005","unstructured":"Korinek J, Wang JW, Sengupta PP, Miyazaki C, Kjaergaard J, McMahon E, Abraham TP, Belohlavek M: Two-dimensional strain - a Doppler-independent ultrasound method for quantitation of regional deformation: Validation in vitro and in vivo. J Am Soc Echocardiogr. 2005, 18: 1247-1253. 10.1016\/j.echo.2005.03.024.","journal-title":"J Am Soc Echocardiogr"},{"key":"86_CR20","volume-title":"Euroecho 8","author":"BH Amundsen","year":"2004","unstructured":"Amundsen BH, Helle-Valle T, Torp H, Crosby J, St\u00f8ylen A, Ihlen H, Smiseth O, Sl\u00f8rdahl SA: Ultrasound speckle tracking reduces angle dependency of myocardial strain estimates - Validation by sonomicrometry. Euroecho 8. 2004, European Association of Echocardiography"},{"key":"86_CR21","doi-asserted-by":"publisher","first-page":"3149","DOI":"10.1161\/CIRCULATIONAHA.104.531558","volume":"112","author":"T Helle-Valle","year":"2005","unstructured":"Helle-Valle T, Crosby J, Edvardsen T, Lyseggen E, Amundsen BH, Smith HJ, Rosen BD, Lima JAC, Torp H, Ihlen H, Smiseth OA: New noninvasive method for assessment of left ventricular rotation - Speckle tracking echocardiography. Circulation. 2005, 112: 3149-3156. 10.1161\/CIRCULATIONAHA.104.531558.","journal-title":"Circulation"},{"key":"86_CR22","first-page":"674","volume-title":"International Joint Conference on Artificial Intelligence (IJCAI)","author":"BD Lucas","year":"1981","unstructured":"Lucas BD, Kanade T: An Iterative Image Registration Technique with an Application to Stereo Vision. International Joint Conference on Artificial Intelligence (IJCAI). 1981, 674-679."},{"key":"86_CR23","volume-title":"Intel Corporation Microprocessor Research Labs","author":"JY Bouguet","year":"2000","unstructured":"Bouguet JY: Pyramidal Implementation of the Lucas Kanade Feature Tracker: Description of the algorithm. Intel Corporation Microprocessor Research Labs. 2000"},{"key":"86_CR24","doi-asserted-by":"publisher","first-page":"559","DOI":"10.1080\/14786440109462720","volume":"2","author":"K Pearson","year":"1901","unstructured":"Pearson K: On lines and planes of closest fit to systems of points in space. Philosophical Magazine. 1901, 2: 559-572.","journal-title":"Philosophical Magazine"},{"key":"86_CR25","doi-asserted-by":"publisher","first-page":"393","DOI":"10.1002\/cem.944","volume":"19","author":"L Eriksson","year":"2005","unstructured":"Eriksson L, Wold S, Trygg J: Multivariate analysis of congruent images (MACI). J Chemometr. 2005, 19: 393-403. 10.1002\/cem.944.","journal-title":"J Chemometr"},{"key":"86_CR26","doi-asserted-by":"publisher","first-page":"57","DOI":"10.1016\/j.chemolab.2004.02.005","volume":"72","author":"MH Bharati","year":"2004","unstructured":"Bharati MH, Liu JJ, MacGregor JF: Image texture analysis: methods and comparisons. Chemometrics Intell Lab Syst. 2004, 72: 57-71. 10.1016\/j.chemolab.2004.02.005.","journal-title":"Chemometrics Intell Lab Syst"},{"key":"86_CR27","doi-asserted-by":"publisher","first-page":"613","DOI":"10.1111\/j.1469-7793.2001.t01-1-00613.x","volume":"534","author":"P Aagaard","year":"2001","unstructured":"Aagaard P, Andersen JL, Dyhre-Poulsen P, Leffers AM, Wagner A, Magnusson SP, Halkj\u00e6r-Kristensen J, Simonsen EB: A mechanism for increased contractile strength of human pennate muscle in response to strength training: changes in muscle architecture. Journal of Physiology. 2001, 534: 613-623. 10.1111\/j.1469-7793.2001.t01-1-00613.x.","journal-title":"Journal of Physiology"},{"key":"86_CR28","doi-asserted-by":"publisher","first-page":"2272","DOI":"10.1016\/j.jbiomech.2008.04.008","volume":"41","author":"G De Monte","year":"2008","unstructured":"De Monte G, Arampatzis A: Influence of different shortening velocities preceding stretch on human triceps surae moment generation in vivo. Journal of Biomechanics. 2008, 41: 2272-2278. 10.1016\/j.jbiomech.2008.04.008.","journal-title":"Journal of Biomechanics"},{"key":"86_CR29","first-page":"17","volume-title":"Chemometrics - Mathematics and Statistics in Chemistry","author":"S Wold","year":"1984","unstructured":"Wold S, Albano C, Dunn WJ, Edlund U, Esbensen K, Geladi P, Hellberg S, Johansson E, Lindberg W, Sj\u00f6str\u00f6m M: Multivariate data analysis in chemistry. Chemometrics - Mathematics and Statistics in Chemistry. Edited by: Kowalski BR. 1984, Dordrecht, The Netherlands: D. Reidel Publishing Company, 17-81."},{"key":"86_CR30","doi-asserted-by":"crossref","first-page":"1230","DOI":"10.1152\/jappl.1998.85.4.1230","volume":"85","author":"L Ito","year":"1998","unstructured":"Ito L, Kawakami Y, Ichinose Y, Fukashiro S, Fukunaga T: Nonisometric behavior of fascicles during isometric contractions of a human muscle. J Appl Physiol. 1998, 85: 1230-1235.","journal-title":"J Appl Physiol"}],"container-title":["BMC Medical Imaging"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/1471-2342-10-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/1471-2342-10-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/1471-2342-10-9","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/1471-2342-10-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,3,27]],"date-time":"2024-03-27T17:34:20Z","timestamp":1711560860000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmedimaging.biomedcentral.com\/articles\/10.1186\/1471-2342-10-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,5,21]]},"references-count":30,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2010,12]]}},"alternative-id":["86"],"URL":"https:\/\/doi.org\/10.1186\/1471-2342-10-9","relation":{},"ISSN":["1471-2342"],"issn-type":[{"value":"1471-2342","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,5,21]]},"assertion":[{"value":"20 July 2009","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 May 2010","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 May 2010","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}],"article-number":"9"}}