{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,2]],"date-time":"2026-03-02T05:41:47Z","timestamp":1772430107595,"version":"3.50.1"},"reference-count":36,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2011,10,17]],"date-time":"2011-10-17T00:00:00Z","timestamp":1318809600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/2.0"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["BMC Med Imaging"],"published-print":{"date-parts":[[2011,12]]},"DOI":"10.1186\/1471-2342-11-20","type":"journal-article","created":{"date-parts":[[2011,10,18]],"date-time":"2011-10-18T06:35:19Z","timestamp":1318919719000},"source":"Crossref","is-referenced-by-count":4,"title":["Estimating radiation effective doses from whole body computed tomography scans based on U.S. soldier patient height and weight"],"prefix":"10.1186","volume":"11","author":[{"given":"Robert D","family":"Prins","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Raymond H","family":"Thornton","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C Ross","family":"Schmidtlein","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Brian","family":"Quinn","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hung","family":"Ching","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lawrence T","family":"Dauer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2011,10,17]]},"reference":[{"issue":"1","key":"124_CR1","doi-asserted-by":"publisher","first-page":"204","DOI":"10.1097\/TA.0b013e3181bdcf95","volume":"68","author":"PJ Belmont Jr","year":"2010","unstructured":"Belmont PJ, Goodman GP, Zacchilli M, Posner M, Evans C, Owens BD: Incidence and epidemiology of combat injuries sustained during \"the surge\" portion of operation iraqi freedom by a U.S. army brigade combat team. Journal of Trauma - Injury, Infection and Critical Care. 2010, 68 (1): 204-210. 10.1097\/TA.0b013e3181bdcf95.","journal-title":"Journal of Trauma - Injury, Infection and Critical Care"},{"issue":"2","key":"124_CR2","doi-asserted-by":"publisher","first-page":"295","DOI":"10.1097\/TA.0b013e318163b875","volume":"64","author":"BD Owens","year":"2008","unstructured":"Owens BD, Kragh JF, Wenke JC, Macaitis J, Wade CE, Holcomb JB: Combat wounds in operation Iraqi Freedom and operation Enduring Freedom. J Trauma. 2008, 64 (2): 295-299. 10.1097\/TA.0b013e318163b875.","journal-title":"J Trauma"},{"issue":"1","key":"124_CR3","doi-asserted-by":"publisher","first-page":"175","DOI":"10.1148\/radiol.2511081296","volume":"251","author":"A Sodickson","year":"2009","unstructured":"Sodickson A, Baeyens PF, Andriole KP, Prevedello LM, Nawfel RD, Hanson R, Khorasani R: Recurrent CT, cumulative radiation exposure, and associated radiation-induced cancer risks from CT of adults. Radiology. 2009, 251 (1): 175-184. 10.1148\/radiol.2511081296.","journal-title":"Radiology"},{"key":"124_CR4","volume-title":"NCRP Report 160","author":"National Council on Radiation Protection and Measurements","year":"2009","unstructured":"National Council on Radiation Protection and Measurements: Ionizing radiation exposure of the population of the United States. NCRP Report 160. 2009"},{"issue":"1","key":"124_CR5","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1007\/s00268-010-0782-z","volume":"35","author":"JJ Morrison","year":"2011","unstructured":"Morrison JJ, Clasper JC, Gibb I, Midwinter M: Management of penetrating abdominal trauma in the conflict environment: The role of computed tomography scanning. World Journal of Surgery. 2011, 35 (1): 27-33. 10.1007\/s00268-010-0782-z.","journal-title":"World Journal of Surgery"},{"issue":"2","key":"124_CR6","doi-asserted-by":"publisher","first-page":"397","DOI":"10.1097\/01.ta.0000203581.75241.f1","volume":"60","author":"JB Holcomb","year":"2006","unstructured":"Holcomb JB, Stansbury LG, Champion HR, Wade C, Bellamy RF: Understanding combat casualty care statistics. J Trauma. 2006, 60 (2): 397-401. 10.1097\/01.ta.0000203581.75241.f1.","journal-title":"J Trauma"},{"issue":"6","key":"124_CR7","doi-asserted-by":"publisher","first-page":"516","DOI":"10.7205\/MILMED.170.6.516","volume":"170","author":"CK Murray","year":"2005","unstructured":"Murray CK, Reynolds JC, Schroeder JM, Harrison MB, Evans OM, Hospenthal DR: Spectrum of care provided at an echelon II Medical Unit during Operation Iraqi Freedom. Mil Med. 2005, 170 (6): 516-520.","journal-title":"Mil Med"},{"issue":"1","key":"124_CR8","doi-asserted-by":"publisher","first-page":"151","DOI":"10.1097\/TA.0b013e31802d9700","volume":"62","author":"H Tien","year":"2007","unstructured":"Tien H, Tremblay L, Rizoli S, Gelberg J, Spencer F, Caldwell C, Brenneman F: Radiation exposure from diagnostic imaging in severely injured trauma patients. J Trauma. 2007, 62 (1): 151-156. 10.1097\/TA.0b013e31802d9700.","journal-title":"J Trauma"},{"issue":"3","key":"124_CR9","doi-asserted-by":"publisher","first-page":"510","DOI":"10.1097\/01.TA.0000141028.97753.67","volume":"57","author":"PK Kim","year":"2004","unstructured":"Kim PK, Gracias VH, Maidment ADA, O'Shea M, Reilly PM, Schwab CW: Cumulative radiation dose caused by radiologic studies in critically ill trauma patients. Journal of Trauma - Injury, Infection and Critical Care. 2004, 57 (3): 510-514. 10.1097\/01.TA.0000141028.97753.67.","journal-title":"Journal of Trauma - Injury, Infection and Critical Care"},{"key":"124_CR10","doi-asserted-by":"crossref","unstructured":"Quantities used in radiological protection. Annals of the ICRP. 1991, 21 (1-3): 4-11.","DOI":"10.1016\/0146-6453(91)90066-P"},{"key":"124_CR11","unstructured":"The Measurement, Reporting, and Management of Radiation Dose in CT, Report 96. Report of AAPM Task Group 23 of the Diagnostic Imaging Council CT Committee. Edited by: American Association of Physicists in Medicine. 2008, College Park: AAPM"},{"key":"124_CR12","unstructured":"Radiation Exposure in X-ray and CT Examinations. [ http:\/\/www.radiologyinfo.org ]"},{"key":"124_CR13","volume-title":"Medical Electrical Equipment. Part 2-44. Particular Requirements for the safety of X-ray equipment for computed tomography","author":"International Electrotechnical Commission","year":"2003","unstructured":"International Electrotechnical Commission: Medical Electrical Equipment. Part 2-44. Particular Requirements for the safety of X-ray equipment for computed tomography. 2003, Geneva, Switzerland: IFC: IFC publication number 60601-2-44 amendment 1, 2","edition":"2"},{"issue":"948","key":"124_CR14","doi-asserted-by":"publisher","first-page":"968","DOI":"10.1259\/bjr\/93277434","volume":"79","author":"PC Shrimpton","year":"2006","unstructured":"Shrimpton PC, Hillier MC, Lewis MA, Dunn M: National survey of doses from CT in the UK: 2003. Br J Radiol. 2006, 79 (948): 968-980. 10.1259\/bjr\/93277434.","journal-title":"Br J Radiol"},{"key":"124_CR15","unstructured":"PCXMC version 2.0. [ http:\/\/www.stuk.fi\/sateilyn_kaytto\/ohjelmat\/PCXMC\/en_GB\/pcxmc\/ ]"},{"issue":"7-8","key":"124_CR16","first-page":"629","volume":"54","author":"D Fulea","year":"2009","unstructured":"Fulea D, Cosma C, Pop IG: Monte Carlo method for radiological X-ray examinations. Romanian Journal in Physics. 2009, 54 (7-8): 629-639.","journal-title":"Romanian Journal in Physics"},{"issue":"7","key":"124_CR17","doi-asserted-by":"publisher","first-page":"702","DOI":"10.7205\/MILMED-D-02-2008","volume":"174","author":"K Reynolds","year":"2009","unstructured":"Reynolds K, Cosio-Lima L, Bovill M, Tharion W, Williams J, Hodges T: A comparison of injuries, limited-duty days, and injury risk factors in infantry, artillery, construction engineers, and Special Forces soliders. Military Medicine. 2009, 174 (7): 702-708.","journal-title":"Military Medicine"},{"issue":"2","key":"124_CR18","doi-asserted-by":"publisher","first-page":"167","DOI":"10.1006\/pmed.1998.0396","volume":"28","author":"KL Reynolds","year":"1999","unstructured":"Reynolds KL, White JS, Knapik JJ, Witt CE, Amoroso PJ: Injuries and risk factors in a 100-mile (161-km) infantry road march. Preventive Medicine. 1999, 28 (2): 167-173. 10.1006\/pmed.1998.0396.","journal-title":"Preventive Medicine"},{"issue":"12","key":"124_CR19","doi-asserted-by":"publisher","first-page":"1503","DOI":"10.1016\/0895-4356(95)00048-8","volume":"48","author":"P Peduzzi","year":"1995","unstructured":"Peduzzi P, Concato J, Feinstein AR, Holford TR: Importance of events per independent variable in proportional hazards regression analysis II. Accuracy and precision of regression estimates. Journal of Clinical Epidemiology. 1995, 48 (12): 1503-1510. 10.1016\/0895-4356(95)00048-8.","journal-title":"Journal of Clinical Epidemiology"},{"issue":"12","key":"124_CR20","doi-asserted-by":"publisher","first-page":"1495","DOI":"10.1016\/0895-4356(95)00510-2","volume":"48","author":"J Concato","year":"1995","unstructured":"Concato J, Peduzzi P, Holford TR, Feinstein AR: Importance of events per independent variable in proportional hazards analysis I. Background, goals, and general strategy. Journal of Clinical Epidemiology. 1995, 48 (12): 1495-1501. 10.1016\/0895-4356(95)00510-2.","journal-title":"Journal of Clinical Epidemiology"},{"key":"124_CR21","unstructured":"LightSpeed Series Technical Reference Manual. Edited by: GE Systems. 2005, 2nd Revision"},{"key":"124_CR22","volume-title":"R: A Language and Environment for Statistical Computing","author":"The R Development Core Team","year":"2007","unstructured":"The R Development Core Team: R: A Language and Environment for Statistical Computing. 2007, Vienna, Austria: R Foundation for Statistical Computing"},{"key":"124_CR23","unstructured":"MicroStar Specifications. [ http:\/\/www.osldosimetry.com\/documents\/MicroStar_Specifications.pdf ]"},{"issue":"2","key":"124_CR24","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1148\/radiol.11101800","volume":"259","author":"CH McCollough","year":"2011","unstructured":"McCollough CH, Leng S, Lifang Y, Cody DD, Boone JM, McNitt-Gray MF: CT Dose Index and Patient Dose: They Are Not the Same Thing. Radiology. 2011, 259 (2): 6-","journal-title":"Radiology"},{"key":"124_CR25","doi-asserted-by":"crossref","unstructured":"Bland JM, Altman DG: Comparing methods of measurement: why plotting difference against standard method is misleading. Lancet. 1995, 3-346","DOI":"10.1016\/S0140-6736(95)91748-9"},{"issue":"2","key":"124_CR26","doi-asserted-by":"publisher","first-page":"194","DOI":"10.1093\/europace\/eup394","volume":"12","author":"JY Wielandts","year":"2010","unstructured":"Wielandts JY, De Buck S, Ector J, LaGerche A, Willems R, Bosmans H, Heidbuchel H: Three-dimensional cardiac rotational angiography: Effective radiation dose and image quality implications. Europace. 2010, 12 (2): 194-201. 10.1093\/europace\/eup394.","journal-title":"Europace"},{"issue":"7","key":"124_CR27","doi-asserted-by":"publisher","first-page":"1850","DOI":"10.1007\/s00330-006-0543-4","volume":"17","author":"G M\u00fchlenbruch","year":"2007","unstructured":"M\u00fchlenbruch G, Hohl C, Das M, Wildberger JE, Suess C, Klotz E, Flohr T, Koos R, Thomas C, G\u00fcnther RW, et al: Evaluation of automated attenuation-based tube current adaptation for coronary calcium scoring in MDCT in a cohort of 262 patients. European Radiology. 2007, 17 (7): 1850-1857. 10.1007\/s00330-006-0543-4.","journal-title":"European Radiology"},{"key":"124_CR28","doi-asserted-by":"crossref","unstructured":"Altman DG, Bland JM: Measurement in Medicine: the Analysis of Method Comparison Studies. The Statistician. 1983, 11-32","DOI":"10.2307\/2987937"},{"issue":"5","key":"124_CR29","doi-asserted-by":"publisher","first-page":"781","DOI":"10.1097\/00000542-199005000-00001","volume":"72","author":"KR LaMantia","year":"1990","unstructured":"LaMantia KR, O'Connor T, Barash PG: Comparing methods of measurement: an alternative approach. Anesthesiology. 1990, 72 (5): 781-783. 10.1097\/00000542-199005000-00001.","journal-title":"Anesthesiology"},{"issue":"3","key":"124_CR30","doi-asserted-by":"publisher","first-page":"995","DOI":"10.1148\/radiol.2483071964","volume":"248","author":"W Huda","year":"2008","unstructured":"Huda W, Ogden K, Khorasani M: Converting dose-length product to effective dose at CT. Radiology. 2008, 248 (3): 995-1003. 10.1148\/radiol.2483071964.","journal-title":"Radiology"},{"key":"124_CR31","doi-asserted-by":"crossref","unstructured":"Fujii K, Aoyama T, Yamauchi-Kawaura C, Koyama S, Yamauchi M, Ko S, Akahane K, Nishizawa K: Radiation dose evaluation in 64-slice CT examinations with adult and paediatric anthropomorphic phantoms. The British Journal of Radiology. 2009, 9-82","DOI":"10.1259\/bjr\/13320880"},{"key":"124_CR32","doi-asserted-by":"crossref","unstructured":"Groves AM, Owen KE, Courtney HM, Yates SJ, Goldstone KE, Blake GM: 16-detector multislice CT: dosimetry estimation by TLD measurement compared with Monte Carlo simulation. The British Journal of Radiology. 2004, 4-77","DOI":"10.1259\/bjr\/48307881"},{"issue":"4","key":"124_CR33","doi-asserted-by":"publisher","first-page":"544","DOI":"10.1097\/RCT.0b013e31802d3dd2","volume":"31","author":"LM Hurwitz","year":"2007","unstructured":"Hurwitz LM, Yoshizumi TT, Goodman PC, Frush DP, Nguyen G, Toncheva G, Lowry C: Effective dose determination using an anthropomorphic phantom and metal oxide semiconductor field effect transistor technology for clinical adult body multidetector array computed tomography protocols. Journal of Computer Assisted Tomography. 2007, 31 (4): 544-549. 10.1097\/RCT.0b013e31802d3dd2.","journal-title":"Journal of Computer Assisted Tomography"},{"issue":"6","key":"124_CR34","doi-asserted-by":"publisher","first-page":"1080","DOI":"10.1118\/1.1481516","volume":"29","author":"JB Sessions","year":"2002","unstructured":"Sessions JB, Roshau JN, Tressler MA, Hintenlang DE, Arreola MM, Williams JL, Bouchet LG, Bolch WE: Comparisons of point and average organ dose within an anthropomorphic physical phantom and a computational model of the newborn patient. Med Phys. 2002, 29 (6): 1080-1089. 10.1118\/1.1481516.","journal-title":"Med Phys"},{"issue":"2","key":"124_CR35","first-page":"79","volume":"57","author":"J Aldrich","year":"2006","unstructured":"Aldrich J, Bilawich A, Mayo J: Radiation doses to patients receiving computed tomography examinations in British Columbia. Can Assoc Radiol J. 2006, 57 (2): 79-85.","journal-title":"Can Assoc Radiol J"},{"issue":"22","key":"124_CR36","doi-asserted-by":"publisher","first-page":"2078","DOI":"10.1001\/archinternmed.2009.427","volume":"169","author":"R Smith-Bindman","year":"2009","unstructured":"Smith-Bindman R, Lipson J, Marcus R, Kim KP, Mahesh M, Gould R, Berrington de Gonzalez A, Miglioretti DL: Radiation dose associated with common computed tomography examinations and the associated lifetime attributable risk of cancer. Arch Intern Med. 2009, 169 (22): 2078-2086. 10.1001\/archinternmed.2009.427.","journal-title":"Arch Intern Med"}],"container-title":["BMC Medical Imaging"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1186\/1471-2342-11-20\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/1471-2342-11-20.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/1471-2342-11-20","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/1471-2342-11-20.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,6,17]],"date-time":"2019-06-17T21:43:37Z","timestamp":1560807817000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmedimaging.biomedcentral.com\/articles\/10.1186\/1471-2342-11-20"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,10,17]]},"references-count":36,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2011,12]]}},"alternative-id":["124"],"URL":"https:\/\/doi.org\/10.1186\/1471-2342-11-20","relation":{},"ISSN":["1471-2342"],"issn-type":[{"value":"1471-2342","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,10,17]]},"article-number":"20"}}