{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T10:45:24Z","timestamp":1777632324409,"version":"3.51.4"},"reference-count":31,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2011,12,1]],"date-time":"2011-12-01T00:00:00Z","timestamp":1322697600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Med Imaging"],"published-print":{"date-parts":[[2011,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Background<\/jats:title><jats:p>Incremental palmar stimulation of the median nerve sensory conduction at the wrist, the \"inching test\", provides an assessment with reference to segments proximal and distal to the entrapment. This study used high-resolution ultrasonography (US) to measure the median nerve's cross-section areas (CSAs) like the \"inching test\" and to correlate with the nerve conduction study (NCS) severity and duration of carpal tunnel syndrome (CTS).<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>Two hundred and twelve (212) \"CTS-hands\" from 135 CTS patients and 50 asymptomatic hands (\"A-hands\") from 25 control individuals were enrolled. The median nerve CSAs were measured at the 8-point marked as<jats:italic>i<\/jats:italic>4,<jats:italic>i<\/jats:italic>3,<jats:italic>i<\/jats:italic>2,<jats:italic>i<\/jats:italic>1,<jats:italic>w<\/jats:italic>,<jats:italic>o<\/jats:italic>1,<jats:italic>o<\/jats:italic>2, and<jats:italic>0<\/jats:italic>3 in inching test. The NCS severities were classified into six groups based on motor and sensory responses (i.e., negative, minimal, mild, moderate, severe, and extreme). Results of US studies were compared in terms of NCS severity and duration of clinical CTS symptoms.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>There was significantly larger CSA of the NCS negative group of \"CTS-hands\" than of \"A-hands\". The cut-off values of the CSAs of the NCS negative CTS group were 12.5 mm<jats:sup>2<\/jats:sup>, 11.5 mm<jats:sup>2<\/jats:sup>and 10.1 mm<jats:sup>2<\/jats:sup>at the inlet, wrist crease, and outlet, respectively. Of the 212 \"CTS-hands\", 32 were NCS negative while 40 had minimal, 43 mild, 85 moderate, 10 severe, and two extreme NCS severities. The CSAs of \"CTS-hands\" positively correlated with different NCS severities and with the duration of CTS symptoms. By duration of clinical symptoms, 12 of the 212 \"CTS-hands\" were in the 1 month group; 82 in &gt;1 month and \u226412 months group, and 118 in &gt;12 months group. In \"inching test\", segments<jats:italic>i<\/jats:italic>4-<jats:italic>i<\/jats:italic>3 and<jats:italic>i<\/jats:italic>3-<jats:italic>i<\/jats:italic>2 were the most common \"positive-site\". The corresponding CSAs measured at<jats:italic>i<\/jats:italic>4 and<jats:italic>i<\/jats:italic>3, but not at<jats:italic>i<\/jats:italic>2, were significantly larger than those measured at points that were not \"positive-site\".<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>Using the 8-point measurement of the median nerve CSA from inlet to outlet similar to the \"inching test\" has positive correlations with NCS severity and duration of CTS clinical symptoms, and can provide more information on anatomic changes. Combined NCS and US studies using the 8-point measurement may have a higher positive rate than NCS alone for diagnosing CTS.<\/jats:p><\/jats:sec>","DOI":"10.1186\/1471-2342-11-22","type":"journal-article","created":{"date-parts":[[2011,12,21]],"date-time":"2011-12-21T19:24:34Z","timestamp":1324495474000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":33,"title":["Ultrasonographic median nerve cross-section areas measured by 8-point \"inching test\" for idiopathic carpal tunnel syndrome: a correlation of nerve conduction study severity and duration of clinical symptoms"],"prefix":"10.1186","volume":"11","author":[{"given":"Shu-Fang","family":"Chen","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cheng-Hsien","family":"Lu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chi-Ren","family":"Huang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yao-Chung","family":"Chuang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nai-Wen","family":"Tsai","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chiung-Chih","family":"Chang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wen-Neng","family":"Chang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2011,12,21]]},"reference":[{"key":"127_CR1","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1097\/00003086-197203000-00007","volume":"83","author":"GS Phalen","year":"1972","unstructured":"Phalen GS: The carpal-tunnel syndrome. Clinical evaluation of 598 hands. Clin Ortho Relat Res. 1972, 83: 29-40.","journal-title":"Clin Ortho Relat Res"},{"key":"127_CR2","doi-asserted-by":"publisher","first-page":"1589","DOI":"10.1212\/WNL.58.11.1589","volume":"58","author":"CK Jablecki","year":"2002","unstructured":"Jablecki CK, Andary MT, Floeter RG, Miller CA, Quartly CA, Vennix MJ, Wilson JR, American Association of Electro-diagnostic Medicine; American Academy of Neurology; American Academy of Physical Medicine and Rehabilitation: Practice parameter; Electro-diagnostic studies in carpal tunnel syndrome. Report of the American Association of Electro-diagnostic Medicine, American Academy of Neurology, and the American Academy of Physical Medicine and Rehabilitation. Neurology. 2002, 58: 1589-1592. 10.1212\/WNL.58.11.1589.","journal-title":"Neurology"},{"key":"127_CR3","first-page":"1353","volume":"119","author":"LD Hobson-Webb","year":"2008","unstructured":"Hobson-Webb LD, Massey JM, Juel VC, Sanders DB: The ultrasonographic wrist-to-forearm median nerve area ratio in carpal tunnel syndrome. ClinNeurophysiol. 2008, 119: 1353-1357.","journal-title":"ClinNeurophysiol"},{"key":"127_CR4","doi-asserted-by":"publisher","first-page":"619","DOI":"10.1093\/brain\/102.3.619","volume":"102","author":"J Kimura","year":"1979","unstructured":"Kimura J: The carpal tunnel syndrome: localization of conduction abnormalities within the distal segment of median nerve. Brain. 1979, 102: 619-635. 10.1093\/brain\/102.3.619.","journal-title":"Brain"},{"key":"127_CR5","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1148\/radiol.2321030071","volume":"232","author":"SM Wong","year":"2004","unstructured":"Wong SM, Griffith JF, Hui ACF, Lo SK, Fu M, Wong KS: Carpal tunnel srndrome: diagnostic usefulness of ultrasonography. Radiology. 2004, 232: 93-99. 10.1148\/radiol.2321030071.","journal-title":"Radiology"},{"key":"127_CR6","doi-asserted-by":"publisher","first-page":"304","DOI":"10.1002\/art.20723","volume":"52","author":"HR Ziswiler","year":"2005","unstructured":"Ziswiler HR, Reichenbach S, Vogelin E, Bachmann LM, Villiger PM, Juni P: Diagnostic value of sonography in patients with suspected carpal tunnel syndrome: a prospective study. Arthritis Rheum. 2005, 52: 304-311. 10.1002\/art.20723.","journal-title":"Arthritis Rheum"},{"key":"127_CR7","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1002\/mus.10227","volume":"27","author":"R Beekman","year":"2003","unstructured":"Beekman R, Visser LH: Sonography in the diagnosis of carpal tunnel syndrome: a critical review of the literature. Muscle Nerve. 2003, 27: 26-33. 10.1002\/mus.10227.","journal-title":"Muscle Nerve"},{"key":"127_CR8","doi-asserted-by":"publisher","first-page":"365","DOI":"10.1016\/j.ejrad.2005.05.013","volume":"56","author":"HR Koyuncuoglu","year":"2005","unstructured":"Koyuncuoglu HR, Kutluhan S, Oyar O, Guler K, Ozden A: The value of ultrasonographic measurement in carpal tunnel syndrome in patients with negative electro-diagnostic tests. Eur J Radiol. 2005, 56: 365-369. 10.1016\/j.ejrad.2005.05.013.","journal-title":"Eur J Radiol"},{"key":"127_CR9","doi-asserted-by":"publisher","first-page":"357","DOI":"10.1002\/art.23317","volume":"59","author":"M Mondelli","year":"2008","unstructured":"Mondelli M, Filippou G, Gallo A, Frediani B: Diagnostic utility of ultrasonography versus nerve conduction studies in mild carpal tunnel syndrome. Arthritis Rheum. 2008, 59: 357-366. 10.1002\/art.23317.","journal-title":"Arthritis Rheum"},{"key":"127_CR10","doi-asserted-by":"publisher","first-page":"2064","DOI":"10.1016\/j.clinph.2008.05.004","volume":"119","author":"L Padua","year":"2008","unstructured":"Padua L, Pazzaglia C, Caliandro P, Granata G, Foschini M, Briani C, Martinoli C: Carpal tunnel syndrome: ultrasound, neurophysiology, clinical and patient-oriented assessment. Clin Neurophysiol. 2008, 119: 2064-2069. 10.1016\/j.clinph.2008.05.004.","journal-title":"Clin Neurophysiol"},{"key":"127_CR11","doi-asserted-by":"publisher","first-page":"2406","DOI":"10.1212\/WNL.43.11.2406","volume":"43","author":"Practice parameter for carpal tunnel syndrome (summary statement)","year":"1993","unstructured":"Practice parameter for carpal tunnel syndrome (summary statement): Report of the Quality Standards Subcommittee of the American Academy of Neurology. Neurology. 1993, 43: 2406-2409.","journal-title":"Neurology"},{"key":"127_CR12","doi-asserted-by":"publisher","first-page":"497","DOI":"10.1002\/(SICI)1097-4598(199904)22:4<497::AID-MUS11>3.0.CO;2-T","volume":"22","author":"H You","year":"1999","unstructured":"You H, Simmons Z, Freivalds A, Kothari MJ, Naidu SH: Relationships between clinical symptom severity scales and nerve conduction measures in CTS. Muscle Nerve. 1999, 22: 497-501. 10.1002\/(SICI)1097-4598(199904)22:4<497::AID-MUS11>3.0.CO;2-T.","journal-title":"Muscle Nerve"},{"key":"127_CR13","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1016\/S0003-9993(21)01687-7","volume":"70","author":"DA Jackson","year":"1989","unstructured":"Jackson DA, Clifford JC: Electro-diagnosis of mild carpal tunnel syndrome. Arch Phys Med Rehabil. 1989, 70: 199-204.","journal-title":"Arch Phys Med Rehabil"},{"key":"127_CR14","doi-asserted-by":"publisher","first-page":"735","DOI":"10.1002\/mus.880120906","volume":"12","author":"A Uncini","year":"1989","unstructured":"Uncini A, Lange DJ, Solomon M, Soliven B, Meer J, Lovelace RE: Ring finger testing in CTS: a comparative study of diagnostic utility. Muscle Nerve. 1989, 12: 735-741. 10.1002\/mus.880120906.","journal-title":"Muscle Nerve"},{"key":"127_CR15","doi-asserted-by":"publisher","first-page":"966","DOI":"10.1002\/mus.1096","volume":"24","author":"RJL Walters","year":"2001","unstructured":"Walters RJL, Murray NMF: Trans-carpal motor conduction velocity in carpal tunnel syndrome. Muscle Nerve. 2001, 24: 966-968. 10.1002\/mus.1096.","journal-title":"Muscle Nerve"},{"key":"127_CR16","first-page":"499","volume":"69","author":"PA Nathan","year":"1988","unstructured":"Nathan PA, Meadows KD, Doyle LS: Sensory segmental latency values of the median nerve for a population of normal individuals. Arch Phys Med Rehabil. 1988, 69: 499-501.","journal-title":"Arch Phys Med Rehabil"},{"key":"127_CR17","doi-asserted-by":"publisher","first-page":"211","DOI":"10.1111\/j.1600-0404.1997.tb00271.x","volume":"96","author":"L Padua","year":"1997","unstructured":"Padua L, LoMonaco M, Gregori B, Valente EM, Padua R, Tonali P: Neuro-physiologic classification and sensitivity in 500 CTS hands. Acta Neurol Scand. 1997, 96: 211-217.","journal-title":"Acta Neurol Scand"},{"key":"127_CR18","doi-asserted-by":"publisher","first-page":"256","DOI":"10.1097\/00002060-200104000-00004","volume":"80","author":"MH Kuo","year":"2001","unstructured":"Kuo MH, Leong CP, Cheng YF, Chang HW: Static wrist position associated with least median nerve compression: sonographic evaluation. Am J Phys Med Rehabil. 2001, 80: 256-260. 10.1097\/00002060-200104000-00004.","journal-title":"Am J Phys Med Rehabil"},{"key":"127_CR19","doi-asserted-by":"publisher","first-page":"489","DOI":"10.1007\/s11547-011-0632-6","volume":"116","author":"M Rahmani","year":"2011","unstructured":"Rahmani M, Ghasemi Esfe AR, Bozorg SM, Mazloumi M, Khalilzadeh O, Kahnouji H: The ultrasonographic correlates of carpal tunnel syndrome in patients with normal electro-diagnostic tests. Radiol Med. 2011, 116: 489-496. 10.1007\/s11547-011-0632-6.","journal-title":"Radiol Med"},{"key":"127_CR20","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1097\/01.sap.0000141942.27182.55","volume":"54","author":"CH Lee","year":"2005","unstructured":"Lee CH, Kim TK, Yoon ES, Dhong ES: Correlation of high-resolution ultrasonographic findings with the clinical symptoms and electro-diagnostic data in carpal tunnel syndrome. Ann Plast Sur. 2005, 54: 20-23. 10.1097\/01.sap.0000141942.27182.55.","journal-title":"Ann Plast Sur"},{"key":"127_CR21","doi-asserted-by":"publisher","first-page":"725","DOI":"10.1016\/0266-7681(94)90245-3","volume":"19","author":"P Seror","year":"1994","unstructured":"Seror P: Sensitivity of the various tests for diagnosis of carpal tunnel syndrome. J Hand Surg Br. 1994, 19: 725-728. 10.1016\/0266-7681(94)90245-3.","journal-title":"J Hand Surg Br"},{"key":"127_CR22","first-page":"744","volume-title":"Neuromuscular Disorders in Clinical Practice","author":"DC Preston","year":"2002","unstructured":"Preston DC: Compressive and entrapment neuropathies of the upper extremity. Neuromuscular Disorders in Clinical Practice. Edited by: Katirji B et al. 2002, Boston: Butterworth-Heinemann, 744-773."},{"key":"127_CR23","doi-asserted-by":"publisher","first-page":"515","DOI":"10.1002\/mus.20019","volume":"29","author":"JC Witt","year":"2004","unstructured":"Witt JC, Hentz JG, Stevens JC: Carpal tunnel syndrome with normal nerve conduction studies. Muscle Nerve. 2004, 29: 515-522. 10.1002\/mus.20019.","journal-title":"Muscle Nerve"},{"key":"127_CR24","doi-asserted-by":"publisher","first-page":"761","DOI":"10.1007\/s00296-009-1061-x","volume":"30","author":"YS Karadag","year":"2010","unstructured":"Karadag YS, Karadag O, Cicekli E, Ozturk S, Kiraz S, Ozbakir S, Filippucci E, Grassi W: Severity of carpal tunnel syndrome assessed with high frequency ultrasonography. Rheumatol Int. 2010, 30: 761-765. 10.1007\/s00296-009-1061-x.","journal-title":"Rheumatol Int"},{"key":"127_CR25","first-page":"516","volume":"13","author":"A Mohammadi","year":"2010","unstructured":"Mohammadi A, Afshar A, Etemadi A, Masoudi S, Baghizadeh A: Diagnostic value of cross-sectional area of median nerve in grading severity of carpal tunnel syndrome. Arch Iran Med. 2010, 13: 516-521.","journal-title":"Arch Iran Med"},{"key":"127_CR26","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1136\/jnnp.2007.115337","volume":"79","author":"LH Visser","year":"2008","unstructured":"Visser LH, Smidt MH, Lee ML: High-resolution sonography versus EMG in the diagnosis of carpal tunnel syndrome. J Neurol Neurosurg Psychiatry. 2008, 79: 63-67. 10.1136\/jnnp.2007.115337.","journal-title":"J Neurol Neurosurg Psychiatry"},{"key":"127_CR27","doi-asserted-by":"publisher","first-page":"767","DOI":"10.1002\/mus.21619","volume":"41","author":"BG Impink","year":"2010","unstructured":"Impink BG, Gagnon D, Collinger JL, Boninger ML: Repeatability of ultrasonographic median nerve measures. Muscle Nerve. 2010, 41: 767-773. 10.1002\/mus.21619.","journal-title":"Muscle Nerve"},{"key":"127_CR28","doi-asserted-by":"publisher","first-page":"415","DOI":"10.1002\/ana.410160402","volume":"16","author":"J Kimura","year":"1984","unstructured":"Kimura J: Principles and pitfalls of nerve conduction studies. Ann Neurol. 1984, 16: 415-429. 10.1002\/ana.410160402.","journal-title":"Ann Neurol"},{"key":"127_CR29","doi-asserted-by":"publisher","first-page":"1557","DOI":"10.1002\/(SICI)1097-4598(199811)21:11<1557::AID-MUS32>3.0.CO;2-V","volume":"21","author":"SR Geiringer","year":"1998","unstructured":"Geiringer SR: Inching Techniques are of limited usage. Muscle Nerve. 1998, 21: 1557-1561. 10.1002\/(SICI)1097-4598(199811)21:11<1557::AID-MUS32>3.0.CO;2-V.","journal-title":"Muscle Nerve"},{"key":"127_CR30","doi-asserted-by":"publisher","first-page":"721","DOI":"10.1007\/s10072-010-0258-9","volume":"31","author":"F Claes","year":"2010","unstructured":"Claes F, Meulstee J, Claessen-Oude Luttikhuis TT, Huygen PL, Verhagen WI: Usefulness of additional measurements of the median nerve with ultrasonography. Neurol Sci. 2010, 31: 721-725. 10.1007\/s10072-010-0258-9.","journal-title":"Neurol Sci"},{"key":"127_CR31","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.apmr.2010.09.012","volume":"92","author":"DW Rha","year":"2011","unstructured":"Rha DW, Im SH, Kim SK, Chang WH, Kim KJ, Lee SC: Median nerve conduction study through the carpal tunnel using segmental nerve length measured by ultrasonographic and conventional tape method. Arch Phys Med Rehabil. 2011, 92: 1-6. 10.1016\/j.apmr.2010.09.012.","journal-title":"Arch Phys Med Rehabil"}],"container-title":["BMC Medical Imaging"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/1471-2342-11-22.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/1471-2342-11-22\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/1471-2342-11-22","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/1471-2342-11-22.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,6,12]],"date-time":"2023-06-12T01:38:49Z","timestamp":1686533929000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmedimaging.biomedcentral.com\/articles\/10.1186\/1471-2342-11-22"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,12]]},"references-count":31,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2011,12]]}},"alternative-id":["127"],"URL":"https:\/\/doi.org\/10.1186\/1471-2342-11-22","relation":{},"ISSN":["1471-2342"],"issn-type":[{"value":"1471-2342","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,12]]},"assertion":[{"value":"30 June 2011","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 December 2011","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 December 2011","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}],"article-number":"22"}}