{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,3]],"date-time":"2026-06-03T10:52:49Z","timestamp":1780483969831,"version":"3.54.1"},"reference-count":16,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2011,2,21]],"date-time":"2011-02-21T00:00:00Z","timestamp":1298246400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/2.0"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["BMC Med Imaging"],"published-print":{"date-parts":[[2011,12]]},"DOI":"10.1186\/1471-2342-11-5","type":"journal-article","created":{"date-parts":[[2011,2,22]],"date-time":"2011-02-22T07:20:02Z","timestamp":1298359202000},"source":"Crossref","is-referenced-by-count":36,"title":["Integration of 3D anatomical data obtained by CT imaging and 3D optical scanning for computer aided implant surgery"],"prefix":"10.1186","volume":"11","author":[{"given":"Gianni","family":"Frisardi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giacomo","family":"Chessa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sandro","family":"Barone","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alessandro","family":"Paoli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Armando","family":"Razionale","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Flavio","family":"Frisardi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2011,2,21]]},"reference":[{"key":"109_CR1","doi-asserted-by":"publisher","first-page":"454","DOI":"10.1111\/j.1365-2842.2007.01816.x","volume":"35","author":"M Vercruyssen","year":"2008","unstructured":"Vercruyssen M, Jacobs R, Van Assche N, van Steenberghe D: The use of CT scan based planning for oral rehabilitation by means of implants and its transfer to the surgical field: a critical review on accuracy. J Oral Rehabil. 2008, 35: 454-474. 10.1111\/j.1365-2842.2007.01816.x.","journal-title":"J Oral Rehabil"},{"key":"109_CR2","first-page":"75","volume":"72","author":"WC Scarfe","year":"2006","unstructured":"Scarfe WC, Farman AG, Sukovic P: Clinical applications of cone-beam computed tomography in dental practice. J Can Dent Assoc. 2006, 72: 75-80.","journal-title":"J Can Dent Assoc"},{"key":"109_CR3","first-page":"599","volume":"18","author":"PB Tardieu","year":"2003","unstructured":"Tardieu PB, Vrielinck L, Escolano E: Computer-assisted implant placement. A case report: treatment of the mandible. Int J Oral Maxillofac Implants. 2003, 18: 599-604.","journal-title":"Int J Oral Maxillofac Implants"},{"key":"109_CR4","doi-asserted-by":"publisher","first-page":"842","DOI":"10.1109\/42.736056","volume":"17","author":"K Verstreken","year":"1998","unstructured":"Verstreken K, Van Cleynenbreugel J, Martens K, Marchal G, van Steenberghe D, Suetens P: An image-guided planning system for endosseous oral implants. IEEE Trans Med Imaging. 1998, 17: 842-852. 10.1109\/42.736056.","journal-title":"IEEE Trans Med Imaging"},{"key":"109_CR5","doi-asserted-by":"publisher","first-page":"272","DOI":"10.1007\/s001380050048","volume":"9","author":"DW Eggert","year":"1997","unstructured":"Eggert DW, Lorusso A, Fischer RB: Estimating 3-D rigid body transformations: a comparison of four major algorithms. Mach Vis Appl. 1997, 9: 272-290. 10.1007\/s001380050048.","journal-title":"Mach Vis Appl"},{"key":"109_CR6","doi-asserted-by":"publisher","first-page":"95","DOI":"10.1002\/rcs.188","volume":"4","author":"A Azari","year":"2008","unstructured":"Azari A, Nikzad S: Computer-assisted implantology: historical background and potential outcomes - a review. Int J Med Robotics Comput Assist Surg. 2008, 4: 95-104. 10.1002\/rcs.188.","journal-title":"Int J Med Robotics Comput Assist Surg"},{"key":"109_CR7","doi-asserted-by":"publisher","first-page":"816","DOI":"10.1111\/j.1600-051X.2007.01110.x","volume":"34","author":"N Van Assche","year":"2007","unstructured":"Van Assche N, van Steenberghe D, Guerrero ME, Hirsch E, Schutyser F, Quirynen M, Jacobs R: Accuracy of implant placement based on pre-surgical planning of three-dimensional cone-beam images: a pilot study. J Clin Periodontol. 2007, 34: 816-821. 10.1111\/j.1600-051X.2007.01110.x.","journal-title":"J Clin Periodontol"},{"key":"109_CR8","first-page":"571","volume":"18","author":"DP Sarment","year":"2003","unstructured":"Sarment DP, Sukovic P, Clinthorne N: Accuracy of implant placement with a stereolithographic surgical guide. Int J Oral Maxillofac Implants. 2003, 18: 571-577.","journal-title":"Int J Oral Maxillofac Implants"},{"key":"109_CR9","doi-asserted-by":"publisher","first-page":"503","DOI":"10.1902\/jop.2005.76.4.503","volume":"76","author":"GA Di Giacomo","year":"2005","unstructured":"Di Giacomo GA, Cury PR, de Araujo NS, Sendyk WR, Sendyk CL: Clinical application of stereolithographic surgical guides for implant placement: preliminary results. J Periodontol. 2005, 76: 503-507. 10.1902\/jop.2005.76.4.503.","journal-title":"J Periodontol"},{"key":"109_CR10","doi-asserted-by":"publisher","first-page":"46","DOI":"10.1097\/ID.0b013e31818c6a50","volume":"18","author":"SA Al-Harbi","year":"2009","unstructured":"Al-Harbi SA, Sun AY: Implant placement accuracy when using stereolithographic template as a surgical guide: preliminary results. Implant Dent. 2009, 18: 46-56. 10.1097\/ID.0b013e31818c6a50.","journal-title":"Implant Dent"},{"key":"109_CR11","doi-asserted-by":"publisher","first-page":"405","DOI":"10.1093\/brain\/awh368","volume":"128","author":"W Mi","year":"2005","unstructured":"Mi W, Beirowski B, Gillingwater TH, Adalbert R, Wagner D, Grumme D, Osaka H, Conforti L, Arnhold S, Addicks K, et al: The slow Wallerian degeneration gene, WldS, inhibits axonal spheroid pathology in gracile axonal dystrophy mice. Brain. 2005, 128: 405-416. 10.1093\/brain\/awh368.","journal-title":"Brain"},{"key":"109_CR12","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1016\/S0304-3959(02)00347-0","volume":"103","author":"A Romaniello","year":"2003","unstructured":"Romaniello A, Cruccu G, Frisardi G, Arendt-Nielsen L, Svensson P: Assessment of nociceptive trigeminal pathways by laser-evoked potentials and laser silent periods in patients with painful temporomandibular disorders. Pain. 2003, 103: 31-39. 10.1016\/S0304-3959(02)00347-0.","journal-title":"Pain"},{"key":"109_CR13","first-page":"264","volume-title":"Proceedings of XXI INGEGRAF: 10-12 June 2009; Lugo","author":"S Barone","year":"2009","unstructured":"Barone S, Paoli A, Razionale AV: An Innovative Methodology for the Design of Custom Dental Prostheses by Optical Scanning. Proceedings of XXI INGEGRAF: 10-12 June 2009; Lugo. Edited by: INGEGRAF. 2009, Lugo, 264-272."},{"key":"109_CR14","unstructured":"3D Slicer (version 3.2). [\n                    http:\/\/www.slicer.org\n                    \n                  ]"},{"key":"109_CR15","doi-asserted-by":"publisher","first-page":"150","DOI":"10.2319\/122407-599.1","volume":"79","author":"AA Brown","year":"2009","unstructured":"Brown AA, Scarfe WC, Scheetz JP, Silveira AM, Farman AG: Linear accuracy of cone beam CT derived 3D images. Angle Orthod. 2009, 79: 150-157. 10.2319\/122407-599.1.","journal-title":"Angle Orthod"},{"key":"109_CR16","doi-asserted-by":"publisher","first-page":"239","DOI":"10.1109\/34.121791","volume":"14","author":"PJ Besl","year":"1992","unstructured":"Besl PJ, McKay ND: A Method for Registration of 3D Shapes. IEEE Trans Pattern Anal Mach Intell. 1992, 14: 239-256. 10.1109\/34.121791.","journal-title":"IEEE Trans Pattern Anal Mach Intell"}],"container-title":["BMC Medical Imaging"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1186\/1471-2342-11-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/1471-2342-11-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/1471-2342-11-5","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/1471-2342-11-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,1,21]],"date-time":"2019-01-21T20:31:46Z","timestamp":1548102706000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmedimaging.biomedcentral.com\/articles\/10.1186\/1471-2342-11-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,2,21]]},"references-count":16,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2011,12]]}},"alternative-id":["109"],"URL":"https:\/\/doi.org\/10.1186\/1471-2342-11-5","relation":{},"ISSN":["1471-2342"],"issn-type":[{"value":"1471-2342","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,2,21]]},"article-number":"5"}}