{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,4]],"date-time":"2025-10-04T12:26:42Z","timestamp":1759580802379},"reference-count":29,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2012,9,27]],"date-time":"2012-09-27T00:00:00Z","timestamp":1348704000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Med Imaging"],"published-print":{"date-parts":[[2012,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Background<\/jats:title><jats:p>Muscle functions are generally assumed to affect a wide variety of conditions and activities, including pain, ischemic and neurological disorders, exercise and injury. It is therefore very desirable to obtain more information on musculoskeletal contributions to and activity during clinical processes such as the treatment of muscle injuries, post-surgery evaluations, and the monitoring of progressive degeneration in neuromuscular disorders.<\/jats:p><jats:p>The spatial image resolution achievable with ultrasound systems has improved tremendously in the last few years and it is nowadays possible to study skeletal muscles in real-time during activity. However, ultrasound imaging has an inherent problem that makes it difficult to compare different measurement series or image sequences from two or more subjects. Due to physiological differences between different subjects, the ultrasound sequences will be visually different \u2013 partly because of variation in probe placement and partly because of the difficulty of perfectly reproducing any given movement.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>Ultrasound images of the biceps and calf of a single subject were transformed to achieve congruence and then efficiently compressed and stacked to facilitate analysis using a multivariate method known as O2PLS. O2PLS identifies related and unrelated variation in and between two sets of data such that different phases of the studied movements can be analysed. The methodology was used to study the dynamics of the Achilles tendon and the calf and also the Biceps brachii and upper arm. The movements of these parts of the body are both of interest in clinical orthopaedic research.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>This study extends the novel method of multivariate analysis of congruent images (MACI) to facilitate comparisons between two series of ultrasound images. This increases its potential range of medical applications and its utility for detecting, visualising and quantifying the dynamics and functions of skeletal muscle.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>The most important results of this study are that MACI with O2PLS is able to consistently extract meaningful variability from pairs of ultrasound sequences. The MACI method with O2PLS is a powerful tool with great potential for visualising and comparing dynamics between movements. It has many potential clinical applications in the study of muscle injuries, post-surgery evaluations and evaluations of rehabilitation, and the assessment of athletic training interventions.<\/jats:p><\/jats:sec>","DOI":"10.1186\/1471-2342-12-29","type":"journal-article","created":{"date-parts":[[2012,9,29]],"date-time":"2012-09-29T04:35:08Z","timestamp":1348893308000},"update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Dynamic ultrasound imaging\u2014A multivariate approach for the analysis and comparison of time-dependent musculoskeletal movements"],"prefix":"10.1186","volume":"12","author":[{"given":"Tommy","family":"L\u00f6fstedt","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Olof","family":"Ahnlund","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael","family":"Peolsson","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Johan","family":"Trygg","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2012,9,27]]},"reference":[{"key":"162_CR1","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1111\/j.1600-0838.2006.00545.x","volume":"17","author":"J N\u00f8rregaard","year":"2007","unstructured":"N\u00f8rregaard J, Larsen CC, Bieler T, Langberg H: Eccentric exercise in treatment of Achilles tendinopathy. Scand J Med Sci Sports. 2007, 17: 133-138.","journal-title":"Scand J Med Sci Sports"},{"key":"162_CR2","doi-asserted-by":"publisher","first-page":"813","DOI":"10.1016\/j.berh.2004.05.001","volume":"18","author":"W Grassi","year":"2004","unstructured":"Grassi W, Filippucci E, Busilacchi P: Musculoskeletal ultrasound. Best Practice & Research Clinical Rheumatology. 2004, 18: 813-826. 10.1016\/j.berh.2004.05.001.","journal-title":"Best Practice & Research Clinical Rheumatology"},{"key":"162_CR3","doi-asserted-by":"publisher","first-page":"823","DOI":"10.1093\/rheumatology\/keh214","volume":"43","author":"D Kane","year":"2004","unstructured":"Kane D, Balint PV, Sturrock R, Grassi W: Musculoskeletal ultrasound - a state of the art review in rheumatology. Part 1: Current controversies and issues in the development of musculoskeletal ultrasound in rheumatology. Rheumatology. 2004, 43: 823-828. 10.1093\/rheumatology\/keh214.","journal-title":"Rheumatology"},{"key":"162_CR4","doi-asserted-by":"publisher","first-page":"1373","DOI":"10.1016\/j.jbiomech.2010.01.001","volume":"43","author":"JW Korstanje","year":"2010","unstructured":"Korstanje JW, Selles R, Stam H, Hovius S, Bosch J: Development and validation of ultrasound speckle tracking to quantify tendon displacement. J Biomech. 2010, 43: 1373-1379. 10.1016\/j.jbiomech.2010.01.001.","journal-title":"J Biomech"},{"key":"162_CR5","volume-title":"Knee Surgery Sports Traumatology, Arthroscopy","author":"A Arndt","year":"2011","unstructured":"Arndt A, Bengtsson A-S, Peolsson M, Thorstensson A, Movin T: Non-uniform displacement within the Achilles tendon during passive ankle joint motion. Knee Surgery Sports Traumatology, Arthroscopy. 2011"},{"key":"162_CR6","doi-asserted-by":"publisher","first-page":"793","DOI":"10.1111\/j.1540-8175.2012.01698.x","volume":"29","author":"D Oxborough","year":"2012","unstructured":"Oxborough D, George K, Birch KM: Intraobserver Reliability of Two-Dimensional Ultrasound Derived Strain Imaging in the Assessment of the Left Ventricle, Right Ventricle, and Left Atrium of Healthy Human Hearts. Echocardiography. 2012, 29: 793-802. 10.1111\/j.1540-8175.2012.01698.x.","journal-title":"Echocardiography"},{"key":"162_CR7","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1186\/1757-1146-1-12","volume":"1","author":"A Cameron","year":"2008","unstructured":"Cameron A, Rome K, Hing W: Ultrasound evaluation of the abductor hallucis muscle: Reliability study. Journal of Foot and Ankle Research. 2008, 1: 12-10.1186\/1757-1146-1-12.","journal-title":"Journal of Foot and Ankle Research"},{"key":"162_CR8","doi-asserted-by":"publisher","first-page":"87","DOI":"10.1016\/j.apmr.2008.06.022","volume":"90","author":"SL Koppenhaver","year":"2009","unstructured":"Koppenhaver SL, Hebert JJ, Fritz JM, Parent EC, Teyhen DS, Magel JS: Reliability of Rehabilitative Ultrasound Imaging of the Transversus Abdominis and Lumbar Multifidus Muscles. Archives of Physical Medicine and Rehabilitation. 2009, 90: 87-94. 10.1016\/j.apmr.2008.06.022.","journal-title":"Archives of Physical Medicine and Rehabilitation"},{"key":"162_CR9","doi-asserted-by":"publisher","first-page":"393","DOI":"10.1002\/cem.944","volume":"19","author":"L Eriksson","year":"2005","unstructured":"Eriksson L, Wold S, Trygg J: Multivariate analysis of congruent images (MACI). J Chemometr. 2005, 19: 393-403. 10.1002\/cem.944.","journal-title":"J Chemometr"},{"key":"162_CR10","volume-title":"BMC Medical Imaging","author":"M Peolsson","year":"2010","unstructured":"Peolsson M, L\u00f6fstedt T, Vogt S, Stenlund H, Arndt A, Trygg J: Modelling human musculoskeletal functional movements using ultrasound imaging. BMC Medical Imaging. 2010, 10:"},{"key":"162_CR11","volume-title":"Digital Image Processing","author":"RC Gonzalez","year":"2002","unstructured":"Gonzalez RC, Woods RE: Digital Image Processing. 2002, New Jersey: Prentice Hall, 2","edition":"2"},{"key":"162_CR12","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1016\/0169-7439(89)80112-1","volume":"7","author":"K Esbensen","year":"1989","unstructured":"Esbensen K, Geladi P: Strategy of multivariate image analysis (MIA). Chemometrics Intell Lab Syst. 1989, 7: 67-86. 10.1016\/0169-7439(89)80112-1.","journal-title":"Chemometrics Intell Lab Syst"},{"key":"162_CR13","doi-asserted-by":"publisher","first-page":"375","DOI":"10.1016\/0169-7439(92)80119-O","volume":"14","author":"P Geladi","year":"1992","unstructured":"Geladi P: Some special topics in multivariate image analysis. Chemometrics Intell Lab Syst. 1992, 14: 375-390. 10.1016\/0169-7439(92)80119-O.","journal-title":"Chemometrics Intell Lab Syst"},{"key":"162_CR14","doi-asserted-by":"publisher","first-page":"209","DOI":"10.1016\/0169-7439(89)80049-8","volume":"5","author":"P Geladi","year":"1989","unstructured":"Geladi P, Isaksson H, Lindqvist L, Wold S, Esbensen K: Principal component analysis of multivariate images. Chemometrics Intell Lab Syst. 1989, 5: 209-220. 10.1016\/0169-7439(89)80049-8.","journal-title":"Chemometrics Intell Lab Syst"},{"key":"162_CR15","doi-asserted-by":"publisher","first-page":"119","DOI":"10.1002\/cem.695","volume":"16","author":"J Trygg","year":"2002","unstructured":"Trygg J, Wold S: Orthogonal projections to latent structures (O-PLS). J Chemometr. 2002, 16: 119-128. 10.1002\/cem.695.","journal-title":"J Chemometr"},{"key":"162_CR16","doi-asserted-by":"publisher","first-page":"283","DOI":"10.1002\/cem.724","volume":"16","author":"J Trygg","year":"2002","unstructured":"Trygg J: O2-PLS for quantitative and qualitative analysis in multivariate calibration. J Chemometr. 2002, 16: 283-293. 10.1002\/cem.724.","journal-title":"J Chemometr"},{"key":"162_CR17","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1002\/cem.775","volume":"17","author":"J Trygg","year":"2003","unstructured":"Trygg J, Wold S: O2-PLS a two-block (X-Y) latent variable regression (LVR) method with an integral OSC filter. J Chemometr. 2003, 17: 53-64. 10.1002\/cem.775.","journal-title":"J Chemometr"},{"key":"162_CR18","doi-asserted-by":"publisher","first-page":"211","DOI":"10.1002\/cem.1180020306","volume":"2","author":"A H\u00f6skuldsson","year":"1988","unstructured":"H\u00f6skuldsson A: PLS Regression Methods. J Chemometr. 1988, 2: 211-228. 10.1002\/cem.1180020306.","journal-title":"J Chemometr"},{"key":"162_CR19","first-page":"411","volume-title":"Research Papers in Statistics: Festschrift for J Neyman","author":"H Wold","year":"1966","unstructured":"Wold H: Nonlinear Estimation by Iterative Least Square Procedures. Research Papers in Statistics: Festschrift for J Neyman. Edited by: David FN. 1966, London: Volume Wiley, 411-444."},{"key":"162_CR20","doi-asserted-by":"crossref","first-page":"286","DOI":"10.1007\/BFb0062108","volume-title":"Matrix Pencils","author":"S Wold","year":"1983","unstructured":"Wold S, Martens H, Wold H: The multivariate calibration problem in chemistry solved by the PLS method. Matrix Pencils. Edited by: K\u00e5gstr\u00f6m B, Ruhe A. 1983, Heidelberg: Springer Berlin, 286-293. Lecture Notes in Mathematics, 973","edition":"973"},{"key":"162_CR21","doi-asserted-by":"publisher","first-page":"6898","DOI":"10.1021\/ac8005318","volume":"80","author":"H Stenlund","year":"2008","unstructured":"Stenlund H, Gorzs\u00e1s A, Persson P, Sundberg B, Trygg J: Orthogonal Projections to Latent Structures Discriminant Analysis Modeling on in Situ FT-IR Spectral Imaging of Liver Tissue for Identifying Sources of Variability. Anal Chem. 2008, 80: 6898-6906. 10.1021\/ac8005318.","journal-title":"Anal Chem"},{"key":"162_CR22","doi-asserted-by":"publisher","first-page":"57","DOI":"10.1016\/j.chemolab.2004.02.005","volume":"72","author":"MH Bharati","year":"2004","unstructured":"Bharati MH, Liu JJ, MacGregor JF: Image texture analysis: methods and comparisons. Chemometrics Intell Lab Syst. 2004, 72: 57-71. 10.1016\/j.chemolab.2004.02.005.","journal-title":"Chemometrics Intell Lab Syst"},{"key":"162_CR23","doi-asserted-by":"publisher","first-page":"1247","DOI":"10.1016\/j.echo.2005.03.024","volume":"18","author":"J Korinek","year":"2005","unstructured":"Korinek J, Wang JW, Sengupta PP, Miyazaki C, Kjaergaard J, McMahon E, Abraham TP, Belohlavek M: Two-dimensional strain - a Doppler-independent ultrasound method for quantitation of regional deformation: Validation in vitro and in vivo. J Am Soc Echocardiogr. 2005, 18: 1247-1253. 10.1016\/j.echo.2005.03.024.","journal-title":"J Am Soc Echocardiogr"},{"key":"162_CR24","volume-title":"Euroecho 8. European Association of Echocardiography","author":"BH Amundsen","year":"2004","unstructured":"Amundsen BH, Helle-Valle T, Torp H, Crosby J, St\u00f8ylen A, Ihlen H, Smiseth O, Sl\u00f8rdahl SA: Ultrasound speckle tracking reduces angle dependency of myocardial strain estimates - Validation by sonomicrometry. Euroecho 8. European Association of Echocardiography. 2004"},{"key":"162_CR25","doi-asserted-by":"publisher","first-page":"3149","DOI":"10.1161\/CIRCULATIONAHA.104.531558","volume":"112","author":"T Helle-Valle","year":"2005","unstructured":"Helle-Valle T, Crosby J, Edvardsen T, Lyseggen E, Amundsen BH, Smith HJ, Rosen BD, Lima JAC, Torp H, Ihlen H, Smiseth OA: New noninvasive method for assessment of left ventricular rotation - Speckle tracking echocardiography. Circulation. 2005, 112: 3149-3156. 10.1161\/CIRCULATIONAHA.104.531558.","journal-title":"Circulation"},{"key":"162_CR26","first-page":"363","volume-title":"Proceedings of the 13th Scandinavian Conference on Image Analysis","author":"G Farneb\u00e4ck","year":"2003","unstructured":"Farneb\u00e4ck G: Two-Frame Motion Estimation Based on Polynomial Expansion. Proceedings of the 13th Scandinavian Conference on Image Analysis. 2003, Sweden: June-July; Gothenburg, 363-370."},{"key":"162_CR27","doi-asserted-by":"publisher","first-page":"511","DOI":"10.1016\/j.jbiomech.2003.09.012","volume":"37","author":"JD Revell","year":"2004","unstructured":"Revell JD, Mirmehdi M, McNally DS: Musculoskeletal motion flow fields using hierarchical variable-sized block matching in ultrasonographic video sequences. J Biomech. 2004, 37: 511-522. 10.1016\/j.jbiomech.2003.09.012.","journal-title":"J Biomech"},{"key":"162_CR28","doi-asserted-by":"publisher","first-page":"178","DOI":"10.1016\/j.compmedimag.2007.01.002","volume":"31","author":"C-H Lin","year":"2007","unstructured":"Lin C-H, Lin MC-J, Sun Y-N: Ultrasound motion estimation using a hierarchical feature weighting algorithm. Computerized Medical Imaging and Graphics. 2007, 31: 178-190. 10.1016\/j.compmedimag.2007.01.002.","journal-title":"Computerized Medical Imaging and Graphics"},{"key":"162_CR29","doi-asserted-by":"crossref","first-page":"1230","DOI":"10.1152\/jappl.1998.85.4.1230","volume":"85","author":"L Ito","year":"1998","unstructured":"Ito L, Kawakami Y, Ichinose Y, Fukashiro S, Fukunaga T: Nonisometric behavior of fascicles during isometric contractions of a human muscle. J Appl Physiol. 1998, 85: 1230-1235.","journal-title":"J Appl Physiol"}],"container-title":["BMC Medical Imaging"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/1471-2342-12-29.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/1471-2342-12-29\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/1471-2342-12-29","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/1471-2342-12-29.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,4,29]],"date-time":"2024-04-29T21:51:20Z","timestamp":1714427480000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmedimaging.biomedcentral.com\/articles\/10.1186\/1471-2342-12-29"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,9,27]]},"references-count":29,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2012,12]]}},"alternative-id":["162"],"URL":"https:\/\/doi.org\/10.1186\/1471-2342-12-29","relation":{},"ISSN":["1471-2342"],"issn-type":[{"value":"1471-2342","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,9,27]]},"assertion":[{"value":"29 April 2012","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 September 2012","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 September 2012","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}],"article-number":"29"}}