{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T22:19:39Z","timestamp":1761862779188},"reference-count":48,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2008,7,31]],"date-time":"2008-07-31T00:00:00Z","timestamp":1217462400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/2.0"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["BMC Med Imaging"],"published-print":{"date-parts":[[2008,12]]},"DOI":"10.1186\/1471-2342-8-14","type":"journal-article","created":{"date-parts":[[2008,9,10]],"date-time":"2008-09-10T18:13:34Z","timestamp":1221070414000},"source":"Crossref","is-referenced-by-count":23,"title":["Multidetector computed tomography angiography for assessment of in-stent restenosis: meta-analysis of diagnostic performance"],"prefix":"10.1186","volume":"8","author":[{"given":"Piet K","family":"Vanhoenacker","sequence":"first","affiliation":[]},{"given":"Isabel","family":"Decramer","sequence":"additional","affiliation":[]},{"given":"Olivier","family":"Bladt","sequence":"additional","affiliation":[]},{"given":"Giovanna","family":"Sarno","sequence":"additional","affiliation":[]},{"given":"Erik","family":"Van Hul","sequence":"additional","affiliation":[]},{"given":"William","family":"Wijns","sequence":"additional","affiliation":[]},{"given":"Ben A","family":"Dwamena","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2008,7,31]]},"reference":[{"key":"54_CR1","doi-asserted-by":"publisher","first-page":"1598","DOI":"10.1016\/S0735-1097(01)01207-4","volume":"37","author":"F Kiemeneij","year":"2001","unstructured":"Kiemeneij F, Serruys PW, Macaya C, Rutsch W, Heyndrickx G, Albertsson P, Fajadet J, Legrand V, Materne P, Belardi J, Sigwart U, Colombo A, Goy JJ, Disco CM, Morel MA: Continued benefit of coronary stenting versus balloon angioplasty: five-year clinical follow-up of Benestent-I trial. J Am Coll Cardiol. 2001, 37: 1598-1603. 10.1016\/S0735-1097(01)01207-4.","journal-title":"J Am Coll Cardiol"},{"key":"54_CR2","doi-asserted-by":"publisher","first-page":"1773","DOI":"10.1056\/NEJMoa012843","volume":"346","author":"MC Morice","year":"2002","unstructured":"Morice MC, Serruys PW, Sousa JE, Fajadet J, Ban HE, Perin M, Colombo A, Schuler G, Barragan P, Guagliumi G, Molnar F, Falotico R: A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization. N Engl J Med. 2002, 346: 1773-1780. 10.1056\/NEJMoa012843.","journal-title":"N Engl J Med"},{"key":"54_CR3","doi-asserted-by":"publisher","first-page":"641","DOI":"10.1136\/hrt.2005.061622","volume":"92","author":"C Roiron","year":"2006","unstructured":"Roiron C, Sanchez P, Bouzamondo A, Lechat P, Montalescot G: Drug eluting stents: an updated meta-analysis of randomised controlled trials. Heart. 2006, 92: 641-649. 10.1136\/hrt.2005.061622.","journal-title":"Heart"},{"key":"54_CR4","doi-asserted-by":"publisher","first-page":"219","DOI":"10.1002\/ccd.1810280305","volume":"28","author":"LW Johnson","year":"1993","unstructured":"Johnson LW, Krone R: Cardiac catheterization 1991: a report of the Registry of the Society for Cardiac Angiography and Interventions (SCA&I). Cathet Cardiovasc Diagn. 1993, 28: 219-220.","journal-title":"Cathet Cardiovasc Diagn"},{"key":"54_CR5","doi-asserted-by":"publisher","first-page":"2345","DOI":"10.1161\/01.CIR.99.17.2345","volume":"99","author":"PJ Scanlon","year":"1999","unstructured":"Scanlon PJ, Faxon DP, Audet AM, Carabello B, Dehmer GJ, Eagle KA, Legako RD, Leon DF, Murray JA, Nissen SE, Pepine CJ, Watson RM, Ritchie JL, Gibbons RJ, Cheitlin MD, Gardner TJ, Garson A, Russell RO, Ryan TJ, Smith SC: ACC\/AHA guidelines for coronary angiography: executive summary and recommendations. A report of the American College of Cardiology\/American Heart Association Task Force on Practice Guidelines (Committee on Coronary Angiography) developed in collaboration with the Society for Cardiac Angiography and Interventions. Circulation. 1999, 99: 2345-2357.","journal-title":"Circulation"},{"key":"54_CR6","doi-asserted-by":"publisher","first-page":"1400","DOI":"10.1016\/S0735-1097(88)80002-0","volume":"12","author":"RM Wyman","year":"1988","unstructured":"Wyman RM, Safian RD, Portway V, Skillman JJ, McKay RG, Baim DS: Current complications of diagnostic and therapeutic cardiac catheterization. J Am Coll Cardiol. 1988, 12: 1400-1406.","journal-title":"J Am Coll Cardiol"},{"key":"54_CR7","doi-asserted-by":"publisher","first-page":"427","DOI":"10.1016\/j.amjcard.2004.04.057","volume":"94","author":"JD Schuijf","year":"2004","unstructured":"Schuijf JD, Bax JJ, Jukema JW, Lamb HJ, Warda HM, Vliegen HW, de RA, Wall van der EE: Feasibility of assessment of coronary stent patency using 16-slice computed tomography. Am J Cardiol. 2004, 94: 427-430. 10.1016\/j.amjcard.2004.04.057.","journal-title":"Am J Cardiol"},{"key":"54_CR8","doi-asserted-by":"publisher","first-page":"799","DOI":"10.1016\/j.amjcard.2005.05.023","volume":"96","author":"F Cademartiri","year":"2005","unstructured":"Cademartiri F, Mollet N, Lemos PA, Pugliese F, Baks T, McFadden EP, Krestin GP, de Feyter PJ: Usefulness of multislice computed tomographic coronary angiography to assess in-stent restenosis. Am J Cardiol. 2005, 96: 799-802. 10.1016\/j.amjcard.2005.05.023.","journal-title":"Am J Cardiol"},{"key":"54_CR9","doi-asserted-by":"publisher","first-page":"110","DOI":"10.1016\/j.amjcard.2004.08.073","volume":"95","author":"M Gilard","year":"2005","unstructured":"Gilard M, Cornily JC, Rioufol G, Finet G, Pennec PY, Mansourati J, Blanc JJ, Boschat J: Noninvasive assessment of left main coronary stent patency with 16-slice computed tomography. Am J Cardiol. 2005, 95: 110-112. 10.1016\/j.amjcard.2004.08.073.","journal-title":"Am J Cardiol"},{"key":"54_CR10","doi-asserted-by":"publisher","first-page":"1573","DOI":"10.1016\/j.jacc.2005.07.049","volume":"46","author":"T Gaspar","year":"2005","unstructured":"Gaspar T, Halon DA, Lewis BS, Adawi S, Schliamser JE, Rubinshtein R, Flugelman MY, Peled N: Diagnosis of coronary in-stent restenosis with multidetector row spiral computed tomography. J Am Coll Cardiol. 2005, 46: 1573-1579. 10.1016\/j.jacc.2005.07.049.","journal-title":"J Am Coll Cardiol"},{"key":"54_CR11","volume-title":"Eur Radiol","author":"V Chabbert","year":"2006","unstructured":"Chabbert V, Carrie D, Bennaceur M, Maupas E, Lauwers V, Mhem M, Lhermusier T, Elbaz M, Joffre F, Rousseau H, Puel J: Evaluation of in-stent restenosis in proximal coronary arteries with multidetector computed tomography (MDCT). Eur Radiol. 2006"},{"key":"54_CR12","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1136\/hrt.2004.056010","volume":"92","author":"M Gilard","year":"2006","unstructured":"Gilard M, Cornily JC, Pennec PY, Le GG, Nonent M, Mansourati J, Blanc JJ, Boschat J: Assessment of coronary artery stents by 16 slice computed tomography. Heart. 2006, 92: 58-61. 10.1136\/hrt.2004.056010.","journal-title":"Heart"},{"key":"54_CR13","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1016\/j.ijcard.2005.05.013","volume":"108","author":"K Ohnuki","year":"2006","unstructured":"Ohnuki K, Yoshida S, Ohta M, Shimizu M, Mochizuki S, Nishioka M, Sakuma T, Fukuda K, Ishizaki M, Hirakawa E, Andou T: New diagnostic technique in multi-slice computed tomography for in-stent restenosis: pixel count method. Int J Cardiol. 2006, 108: 251-258. 10.1016\/j.ijcard.2005.05.013.","journal-title":"Int J Cardiol"},{"key":"54_CR14","doi-asserted-by":"publisher","first-page":"691","DOI":"10.1253\/circj.70.691","volume":"70","author":"M Watanabe","year":"2006","unstructured":"Watanabe M, Uemura S, Iwama H, Okayama S, Takeda Y, Kawata H, Horii M, Nakajima T, Hirohashi S, Kichikawa K, Ookura A, Saito Y: Usefulness of 16-slice multislice spiral computed tomography for follow-up study of coronary stent implantation. Circ J. 2006, 70: 691-697. 10.1253\/circj.70.691.","journal-title":"Circ J"},{"key":"54_CR15","doi-asserted-by":"publisher","first-page":"645","DOI":"10.1161\/CIRCULATIONAHA.105.608950","volume":"114","author":"CA Van Mieghem","year":"2006","unstructured":"Van Mieghem CA, Cademartiri F, Mollet NR, Malagutti P, Valgimigli M, Meijboom WB, Pugliese F, McFadden EP, Ligthart J, Runza G, Bruining N, Smits PC, Regar E, Giessen van der WJ, Sianos G, van DR, de JP, Krestin GP, Serruys PW, de Feyter PJ: Multislice spiral computed tomography for the evaluation of stent patency after left main coronary artery stenting: a comparison with conventional coronary angiography and intravascular ultrasound. Circulation. 2006, 114: 645-653. 10.1161\/CIRCULATIONAHA.105.608950.","journal-title":"Circulation"},{"key":"54_CR16","doi-asserted-by":"publisher","first-page":"1465","DOI":"10.1016\/j.acra.2006.09.044","volume":"13","author":"C Rist","year":"2006","unstructured":"Rist C, von ZF, Nikolaou K, Kirchin MA, Wintersperger BJ, Johnson TR, Knez A, Leber AW, Reiser MF, Becker CR: Assessment of coronary artery stent patency and restenosis using 64-slice computed tomography. Acad Radiol. 2006, 13: 1465-1473. 10.1016\/j.acra.2006.09.044.","journal-title":"Acad Radiol"},{"key":"54_CR17","doi-asserted-by":"publisher","first-page":"2567","DOI":"10.1093\/eurheartj\/ehl303","volume":"27","author":"J Rixe","year":"2006","unstructured":"Rixe J, Achenbach S, Ropers D, Baum U, Kuettner A, Ropers U, Bautz W, Daniel WG, Anders K: Assessment of coronary artery stent restenosis by 64-slice multi-detector computed tomography. Eur Heart J. 2006, 27: 2567-2572. 10.1093\/eurheartj\/ehl303.","journal-title":"Eur Heart J"},{"key":"54_CR18","doi-asserted-by":"publisher","first-page":"87","DOI":"10.1007\/s00330-006-0291-5","volume":"17","author":"JM Kefer","year":"2007","unstructured":"Kefer JM, Coche E, Vanoverschelde JL, Gerber BL: Diagnostic accuracy of 16-slice multidetector-row CT for detection of in-stent restenosis vs detection of stenosis in nonstented coronary arteries. Eur Radiol. 2007, 17: 87-96. 10.1007\/s00330-006-0291-5.","journal-title":"Eur Radiol"},{"key":"54_CR19","doi-asserted-by":"publisher","first-page":"951","DOI":"10.1016\/j.jacc.2006.10.065","volume":"49","author":"M Ehara","year":"2007","unstructured":"Ehara M, Kawai M, Surmely JF, Matsubara T, Terashima M, Tsuchikane E, Kinoshita Y, Ito T, Takeda Y, Nasu K, Tanaka N, Murata A, Fujita H, Sato K, Kodama A, Katoh O, Suzuki T: Diagnostic accuracy of coronary in-stent restenosis using 64-slice computed tomography comparison with invasive coronary angiography. J Am Coll Cardiol. 2007, 49: 951-959. 10.1016\/j.jacc.2006.10.065.","journal-title":"J Am Coll Cardiol"},{"key":"54_CR20","doi-asserted-by":"publisher","first-page":"403","DOI":"10.1148\/radiol.2422060065","volume":"242","author":"D Oncel","year":"2007","unstructured":"Oncel D, Oncel G, Karaca M: Coronary stent patency and in-stent restenosis: determination with 64-section multidetector CT coronary angiography\u2013initial experience. Radiology. 2007, 242: 403-409. 10.1148\/radiol.2422060065.","journal-title":"Radiology"},{"key":"54_CR21","doi-asserted-by":"crossref","first-page":"830","DOI":"10.1007\/s00330-002-1651-4","volume":"13","author":"D Maintz","year":"2003","unstructured":"Maintz D, Juergens KU, Wichter T, Grude M, Heindel W, Fischbach R: Imaging of coronary artery stents using multislice computed tomography: in vitro evaluation. Eur Radiol. 2003, 13: 830-835.","journal-title":"Eur Radiol"},{"key":"54_CR22","doi-asserted-by":"publisher","first-page":"597","DOI":"10.1046\/j.1600-0455.2003.00130.x","volume":"44","author":"D Maintz","year":"2003","unstructured":"Maintz D, Grude M, Fallenberg EM, Heindel W, Fischbach R: Assessment of coronary arterial stents by multislice-CT angiography. Acta Radiol. 2003, 44: 597-603. 10.1046\/j.1600-0455.2003.00130.x.","journal-title":"Acta Radiol"},{"key":"54_CR23","doi-asserted-by":"publisher","first-page":"1089","DOI":"10.1136\/bmj.332.7549.1089","volume":"332","author":"PM Bossuyt","year":"2006","unstructured":"Bossuyt PM, Irwig L, Craig J, Glasziou P: Comparative accuracy: assessing new tests against existing diagnostic pathways. BMJ. 2006, 332: 1089-1092. 10.1136\/bmj.332.7549.1089.","journal-title":"BMJ"},{"key":"54_CR24","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1148\/radiol.2421052135","volume":"242","author":"M Staunton","year":"2007","unstructured":"Staunton M: Evidence-based radiology: steps 1 and 2\u2013asking answerable questions and searching for evidence. Radiology. 2007, 242: 23-31. 10.1148\/radiol.2421052135.","journal-title":"Radiology"},{"key":"54_CR25","doi-asserted-by":"publisher","first-page":"1040","DOI":"10.1136\/bmj.38068.557998.EE","volume":"328","author":"RB Haynes","year":"2004","unstructured":"Haynes RB, Wilczynski NL: Optimal search strategies for retrieving scientifically strong studies of diagnosis from Medline: analytical survey. BMJ. 2004, 328: 1040-10.1136\/bmj.38068.557998.EE.","journal-title":"BMJ"},{"key":"54_CR26","doi-asserted-by":"publisher","first-page":"1054","DOI":"10.1001\/jama.282.11.1054","volume":"282","author":"P Juni","year":"1999","unstructured":"Juni P, Witschi A, Bloch R, Egger M: The hazards of scoring the quality of clinical trials for meta-analysis. JAMA. 1999, 282: 1054-1060. 10.1001\/jama.282.11.1054.","journal-title":"JAMA"},{"key":"54_CR27","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1186\/1471-2288-3-25","volume":"3","author":"P Whiting","year":"2003","unstructured":"Whiting P, Rutjes AW, Reitsma JB, Bossuyt PM, Kleijnen J: The development of QUADAS: a tool for the quality assessment of studies of diagnostic accuracy included in systematic reviews. BMC Med Res Methodol. 2003, 3: 25-10.1186\/1471-2288-3-25.","journal-title":"BMC Med Res Methodol"},{"key":"54_CR28","doi-asserted-by":"publisher","first-page":"415","DOI":"10.1016\/S0304-3959(99)00302-4","volume":"85","author":"DJ Gavaghan","year":"2000","unstructured":"Gavaghan DJ, Moore RA, McQuay HJ: An evaluation of homogeneity tests in meta-analyses in pain using simulations of individual patient data. Pain. 2000, 85: 415-424. 10.1016\/S0304-3959(99)00302-4.","journal-title":"Pain"},{"key":"54_CR29","doi-asserted-by":"publisher","first-page":"1539","DOI":"10.1002\/sim.1186","volume":"21","author":"JP Higgins","year":"2002","unstructured":"Higgins JP, Thompson SG: Quantifying heterogeneity in a meta-analysis. Stat Med. 2002, 21: 1539-1558. 10.1002\/sim.1186.","journal-title":"Stat Med"},{"key":"54_CR30","doi-asserted-by":"publisher","first-page":"557","DOI":"10.1136\/bmj.327.7414.557","volume":"327","author":"JP Higgins","year":"2003","unstructured":"Higgins JP, Thompson SG, Deeks JJ, Altman DG: Measuring inconsistency in meta-analyses. BMJ. 2003, 327: 557-560. 10.1136\/bmj.327.7414.557.","journal-title":"BMJ"},{"key":"54_CR31","doi-asserted-by":"publisher","first-page":"882","DOI":"10.1016\/j.jclinepi.2005.01.016","volume":"58","author":"JJ Deeks","year":"2005","unstructured":"Deeks JJ, Macaskill P, Irwig L: The performance of tests of publication bias and other sample size effects in systematic reviews of diagnostic test accuracy was assessed. J Clin Epidemiol. 2005, 58: 882-893. 10.1016\/j.jclinepi.2005.01.016.","journal-title":"J Clin Epidemiol"},{"key":"54_CR32","doi-asserted-by":"publisher","first-page":"629","DOI":"10.1136\/bmj.315.7109.629","volume":"315","author":"M Egger","year":"1997","unstructured":"Egger M, Davey SG, Schneider M, Minder C: Bias in meta-analysis detected by a simple, graphical test. BMJ. 1997, 315: 629-634.","journal-title":"BMJ"},{"key":"54_CR33","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1136\/bmj.323.7304.101","volume":"323","author":"JA Sterne","year":"2001","unstructured":"Sterne JA, Egger M, Smith GD: Systematic reviews in health care: Investigating and dealing with publication and other biases in meta-analysis. BMJ. 2001, 323: 101-105. 10.1136\/bmj.323.7304.101.","journal-title":"BMJ"},{"key":"54_CR34","doi-asserted-by":"publisher","first-page":"313","DOI":"10.1177\/0272989X9301300408","volume":"13","author":"B Littenberg","year":"1993","unstructured":"Littenberg B, Moses LE: Estimating diagnostic accuracy from multiple conflicting reports: a new meta-analytic method. Med Decis Making. 1993, 13: 313-321. 10.1177\/0272989X9301300408.","journal-title":"Med Decis Making"},{"key":"54_CR35","doi-asserted-by":"publisher","first-page":"1293","DOI":"10.1002\/sim.4780121403","volume":"12","author":"LE Moses","year":"1993","unstructured":"Moses LE, Shapiro D, Littenberg B: Combining independent studies of a diagnostic test into a summary ROC curve: data-analytic approaches and some additional considerations. Stat Med. 1993, 12: 1293-1316.","journal-title":"Stat Med"},{"key":"54_CR36","doi-asserted-by":"publisher","first-page":"982","DOI":"10.1016\/j.jclinepi.2005.02.022","volume":"58","author":"JB Reitsma","year":"2005","unstructured":"Reitsma JB, Glas AS, Rutjes AW, Scholten RJ, Bossuyt PM, Zwinderman AH: Bivariate analysis of sensitivity and specificity produces informative summary measures in diagnostic reviews. J Clin Epidemiol. 2005, 58: 982-990. 10.1016\/j.jclinepi.2005.02.022.","journal-title":"J Clin Epidemiol"},{"key":"54_CR37","doi-asserted-by":"publisher","first-page":"419","DOI":"10.1148\/radiol.2442061218","volume":"244","author":"PK Vanhoenacker","year":"2007","unstructured":"Vanhoenacker PK, Heijenbrok-Kal MH, Van Heste R, Decramer I, Van Hoe LR, Wijns W, Hunink MG: Diagnostic performance of multidetector CT angiography for assessment of coronary artery disease: meta-analysis. Radiology. 2007, 244: 419-428. 10.1148\/radiol.2442061218.","journal-title":"Radiology"},{"key":"54_CR38","doi-asserted-by":"publisher","first-page":"687","DOI":"10.1002\/sim.2992","volume":"27","author":"AH Zwinderman","year":"2008","unstructured":"Zwinderman AH, Bossuyt PM: We should not pool diagnostic likelihood ratios in systematic reviews. Stat Med. 2008, 27: 687-697. 10.1002\/sim.2992.","journal-title":"Stat Med"},{"key":"54_CR39","doi-asserted-by":"publisher","first-page":"703","DOI":"10.1001\/jama.1994.03510330081039","volume":"271","author":"R Jaeschke","year":"1994","unstructured":"Jaeschke R, Guyatt GH, Sackett DL: Users' guides to the medical literature. III. How to use an article about a diagnostic test. B. What are the results and will they help me in caring for my patients? The Evidence-Based Medicine Working Group. JAMA. 1994, 271: 703-707. 10.1001\/jama.271.9.703.","journal-title":"JAMA"},{"key":"54_CR40","doi-asserted-by":"publisher","first-page":"253","DOI":"10.1046\/j.1365-2796.2003.01101.x","volume":"253","author":"G Dori","year":"2003","unstructured":"Dori G, Denekamp Y, Fishman S, Bitterman H: Exercise stress testing, myocardial perfusion imaging and stress echocardiography for detecting restenosis after successful percutaneous transluminal coronary angioplasty: a review of performance. J Intern Med. 2003, 253: 253-262. 10.1046\/j.1365-2796.2003.01101.x.","journal-title":"J Intern Med"},{"key":"54_CR41","doi-asserted-by":"publisher","first-page":"1480","DOI":"10.1136\/hrt.2005.086140","volume":"92","author":"A Elhendy","year":"2006","unstructured":"Elhendy A, Tsutsui JM, O'Leary EL, Xie F, Majeed F, Porter TR: Evaluation of restenosis and extent of coronary artery disease in patients with previous percutaneous coronary interventions by dobutamine stress real-time myocardial contrast perfusion imaging. Heart. 2006, 92: 1480-1483. 10.1136\/hrt.2005.086140.","journal-title":"Heart"},{"key":"54_CR42","doi-asserted-by":"publisher","first-page":"657","DOI":"10.1007\/s10554-006-9087-6","volume":"22","author":"A Elhendy","year":"2006","unstructured":"Elhendy A, Schinkel AF, van Domberg RT, Bax JJ, Valkema R, Poldermans D: Non-invasive diagnosis of in stent stenosis by stress 99 m technetium tetrofosmin myocardial perfusion imaging. Int J Cardiovasc Imaging. 2006, 22: 657-662. 10.1007\/s10554-006-9087-6.","journal-title":"Int J Cardiovasc Imaging"},{"key":"54_CR43","doi-asserted-by":"publisher","first-page":"359","DOI":"10.1081\/JCMR-120013303","volume":"4","author":"D Maintz","year":"2002","unstructured":"Maintz D, Botnar RM, Fischbach R, Heindel W, Manning WJ, Stuber M: Coronary magnetic resonance angiography for assessment of the stent lumen: a phantom study. J Cardiovasc Magn Reson. 2002, 4: 359-367. 10.1081\/JCMR-120013303.","journal-title":"J Cardiovasc Magn Reson"},{"key":"54_CR44","doi-asserted-by":"publisher","first-page":"193","DOI":"10.1007\/s003300101017","volume":"12","author":"F Sardanelli","year":"2002","unstructured":"Sardanelli F, Zandrino F, Molinari G, Iozzelli A, Balbi M, Barsotti A: MR evaluation of coronary stents with navigator echo and breath-hold cine gradient-echo techniques. Eur Radiol. 2002, 12: 193-200. 10.1007\/s003300101017.","journal-title":"Eur Radiol"},{"key":"54_CR45","doi-asserted-by":"publisher","first-page":"1019","DOI":"10.1161\/01.CIR.0000156462.97532.8F","volume":"111","author":"E Spuentrup","year":"2005","unstructured":"Spuentrup E, Ruebben A, Mahnken A, Stuber M, Kolker C, Nguyen TH, Gunther RW, Buecker A: Artifact-free coronary magnetic resonance angiography and coronary vessel wall imaging in the presence of a new, metallic, coronary magnetic resonance imaging stent. Circulation. 2005, 111: 1019-1026. 10.1161\/01.CIR.0000156462.97532.8F.","journal-title":"Circulation"},{"key":"54_CR46","doi-asserted-by":"publisher","first-page":"1305","DOI":"10.1161\/CIRCULATIONAHA.105.602490","volume":"113","author":"J Hausleiter","year":"2006","unstructured":"Hausleiter J, Meyer T, Hadamitzky M, Huber E, Zankl M, Martinoff S, Kastrati A, Schomig A: Radiation dose estimates from cardiac multislice computed tomography in daily practice: impact of different scanning protocols on effective dose estimates. Circulation. 2006, 113: 1305-1310. 10.1161\/CIRCULATIONAHA.105.602490.","journal-title":"Circulation"},{"key":"54_CR47","first-page":"42","volume":"110","author":"F Cademartiri","year":"2005","unstructured":"Cademartiri F, Runza G, Mollet NR, Luccichenti G, Belgrano M, Bartolotta TV, Galia M, Midiri M, Pozzi MR, Krestin GP: Impact of intravascular enhancement, heart rate, and calcium score on diagnostic accuracy in multislice computed tomography coronary angiography. Radiol Med (Torino). 2005, 110: 42-51.","journal-title":"Radiol Med (Torino)"},{"key":"54_CR48","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1007\/s10554-005-9010-6","volume":"22","author":"F Cademartiri","year":"2006","unstructured":"Cademartiri F, Mollet NR, Runza G, Belgrano M, Malagutti P, Meijboom BW, Midiri M, Feyter PJ, Krestin GP: Diagnostic accuracy of multislice computed tomography coronary angiography is improved at low heart rates. Int J Cardiovasc Imaging. 2006, 22: 101-105. 10.1007\/s10554-005-9010-6.","journal-title":"Int J Cardiovasc Imaging"}],"container-title":["BMC Medical Imaging"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1186\/1471-2342-8-14\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/1471-2342-8-14.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/1471-2342-8-14","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/1471-2342-8-14.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,5,8]],"date-time":"2020-05-08T05:52:16Z","timestamp":1588917136000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmedimaging.biomedcentral.com\/articles\/10.1186\/1471-2342-8-14"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,7,31]]},"references-count":48,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2008,12]]}},"alternative-id":["54"],"URL":"https:\/\/doi.org\/10.1186\/1471-2342-8-14","relation":{},"ISSN":["1471-2342"],"issn-type":[{"value":"1471-2342","type":"electronic"}],"subject":[],"published":{"date-parts":[[2008,7,31]]},"article-number":"14"}}