{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,19]],"date-time":"2026-10-19T17:53:22Z","timestamp":1792432402389,"version":"4.5.0"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2008,5,12]],"date-time":"2008-05-12T00:00:00Z","timestamp":1210550400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["BMC Neurol"],"published-print":{"date-parts":[[2008,12]]},"DOI":"10.1186\/1471-2377-8-14","type":"journal-article","created":{"date-parts":[[2008,5,13]],"date-time":"2008-05-13T06:14:30Z","timestamp":1210659270000},"source":"Crossref","is-referenced-by-count":50,"title":["Cooling via one hand improves physical performance in heat-sensitive individuals with Multiple Sclerosis: A preliminary study"],"prefix":"10.1186","volume":"8","author":[{"given":"Dennis A","family":"Grahn","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Julie vLS","family":"Murray","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"H Craig","family":"Heller","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2008,5,12]]},"reference":[{"issue":"2","key":"176_CR1","doi-asserted-by":"publisher","first-page":"513","DOI":"10.1016\/j.pmr.2005.01.005","volume":"16","author":"TR Brown","year":"2005","unstructured":"Brown TR, Kraft GH: Exercise and rehabilitation for individuals with multiple sclerosis. Phys Med Rehabil Clin N Am. 2005, 16 (2): 513-555.","journal-title":"Phys Med Rehabil Clin N Am"},{"issue":"7","key":"176_CR2","doi-asserted-by":"publisher","first-page":"839","DOI":"10.1007\/s00415-005-0759-2","volume":"252","author":"A Romberg","year":"2005","unstructured":"Romberg A, Virtanen A, Ruutiainen J: Long-term exercise improves functional impairment but not quality of life in multiple sclerosis. J Neurol. 2005, 252 (7): 839-845. 10.1007\/s00415-005-0759-2.","journal-title":"J Neurol"},{"issue":"11","key":"176_CR3","doi-asserted-by":"publisher","first-page":"2034","DOI":"10.1212\/01.WNL.0000145761.38400.65","volume":"63","author":"A Romberg","year":"2004","unstructured":"Romberg A, Virtanen A, Ruutiainen J, Aunola S, Karppi SL, Vaara M, Surakka J, Pohjolainen T, Seppanen A: Effects of a 6-month exercise program on patients with multiple sclerosis: a randomized study. Neurology. 2004, 63 (11): 2034-2038.","journal-title":"Neurology"},{"key":"176_CR4","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1177\/154596839601000104","volume":"10","author":"KJM Syndulko","year":"1996","unstructured":"Syndulko KJM, Woldanski A, Baumhefner RW, Tourtellotte WW: Effects of temperature in multiple sclerosis: A review of the literature. Neurorehabil Neural Repair. 1996, 10: 23-34. 10.1177\/154596839601000104.","journal-title":"Neurorehabil Neural Repair"},{"issue":"15","key":"176_CR5","doi-asserted-by":"publisher","first-page":"1077","DOI":"10.2165\/00007256-200434150-00005","volume":"34","author":"LJ White","year":"2004","unstructured":"White LJ, Dressendorfer RH: Exercise and multiple sclerosis. Sports Med. 2004, 34 (15): 1077-1100. 10.2165\/00007256-200434150-00005.","journal-title":"Sports Med"},{"issue":"2","key":"176_CR6","doi-asserted-by":"publisher","first-page":"483","DOI":"10.1016\/j.pmr.2005.01.014","volume":"16","author":"WS MacAllister","year":"2005","unstructured":"MacAllister WS, Krupp LB: Multiple sclerosis-related fatigue. Phys Med Rehabil Clin N Am. 2005, 16 (2): 483-502.","journal-title":"Phys Med Rehabil Clin N Am"},{"issue":"4","key":"176_CR7","doi-asserted-by":"publisher","first-page":"531","DOI":"10.1136\/jnnp.2005.064410","volume":"77","author":"M van der Berg","year":"2006","unstructured":"van der Berg M, Dawes H, Wade DT, Newman M, Burridge J, Izadi H, Sackley CM: Treadmill training for individuals with multiple sclerosis: a pilot randomised trial. J Neurol Neurosurg Psychiatry. 2006, 77 (4): 531-533. 10.1136\/jnnp.2005.064410.","journal-title":"J Neurol Neurosurg Psychiatry"},{"issue":"3","key":"176_CR8","doi-asserted-by":"publisher","first-page":"176","DOI":"10.1177\/135245850000600307","volume":"6","author":"AT White","year":"2000","unstructured":"White AT, Wilson TE, Davis SL, Petajan JH: Effect of precooling on physical performance in multiple sclerosis. Mult Scler. 2000, 6 (3): 176-180.","journal-title":"Mult Scler"},{"issue":"2","key":"176_CR9","doi-asserted-by":"publisher","first-page":"195","DOI":"10.1111\/j.1748-1716.1993.tb09489.x","volume":"147","author":"TK Bergersen","year":"1993","unstructured":"Bergersen TK: A search for arteriovenous anastomoses in human skin using ultrasound Doppler. Acta Physiol Scand. 1993, 147 (2): 195-201.","journal-title":"Acta Physiol Scand"},{"issue":"1","key":"176_CR10","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1152\/physrev.1974.54.1.75","volume":"54","author":"LB Rowell","year":"1974","unstructured":"Rowell LB: Human cardiovascular adjustments to exercise and thermal stress. Physiol Rev. 1974, 54 (1): 75-159.","journal-title":"Physiol Rev"},{"key":"176_CR11","first-page":"1325","volume-title":"Handbook of physiology Section 2: Circulation","author":"A Greenfield","year":"1963","unstructured":"Greenfield A: The circulation through the skin. Handbook of physiology Section 2: Circulation. Edited by: Hamilton W, Dow P. 1963, Washington, DC: American Physiological Society, 2: 1325-1351."},{"issue":"1","key":"176_CR12","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1136\/jrnms-77-41","volume":"77","author":"AJ Allsopp","year":"1991","unstructured":"Allsopp AJ, Poole KA: The effect of hand immersion on body temperature when wearing impermeable clothing. J R Nav Med Serv. 1991, 77 (1): 41-47.","journal-title":"J R Nav Med Serv"},{"issue":"1","key":"176_CR13","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1136\/jrnms-83-26","volume":"83","author":"JR House","year":"1997","unstructured":"House JR, Holmes C, Allsopp AJ: Prevention of heat strain by immersing the hands and forearms in water. J R Nav Med Serv. 1997, 83 (1): 26-30.","journal-title":"J R Nav Med Serv"},{"issue":"12","key":"176_CR14","first-page":"1166","volume":"60","author":"SD Livingstone","year":"1989","unstructured":"Livingstone SD, Nolan RW, Cattroll SW: Heat loss caused by immersing the hands in water. Aviat Space Environ Med. 1989, 60 (12): 1166-1171.","journal-title":"Aviat Space Environ Med"},{"issue":"3","key":"176_CR15","first-page":"232","volume":"66","author":"SD Livingstone","year":"1995","unstructured":"Livingstone SD, Nolan RW, Keefe AA: Heat loss caused by cooling the feet. Aviat Space Environ Med. 1995, 66 (3): 232-237.","journal-title":"Aviat Space Environ Med"},{"issue":"8","key":"176_CR16","doi-asserted-by":"publisher","first-page":"521","DOI":"10.1080\/15459620490475216","volume":"1","author":"GA Selkirk","year":"2004","unstructured":"Selkirk GA, McLellan TM, Wong J: Active versus passive cooling during work in warm environments while wearing firefighting protective clothing. J Occup Environ Hyg. 2004, 1 (8): 521-531. 10.1080\/15459620490475216.","journal-title":"J Occup Environ Hyg"},{"issue":"3","key":"176_CR17","first-page":"125","volume":"79","author":"MJ Tipton","year":"1993","unstructured":"Tipton MJ, Allsopp A, Balmi PJ, House JR: Hand immersion as a method of cooling and rewarming: a short review. J R Nav Med Serv. 1993, 79 (3): 125-131.","journal-title":"J R Nav Med Serv"},{"issue":"11","key":"176_CR18","first-page":"1081","volume":"70","author":"L Vanggaard","year":"1999","unstructured":"Vanggaard L, Eyolfson D, Xu X, Weseen G, Giesbrecht GG: Immersion of distal arms and legs in warm water (AVA rewarming) effectively rewarms mildly hypothermic humans. Aviat Space Environ Med. 1999, 70 (11): 1081-1088.","journal-title":"Aviat Space Environ Med"},{"issue":"5","key":"176_CR19","doi-asserted-by":"crossref","first-page":"1643","DOI":"10.1152\/jappl.1998.85.5.1643","volume":"85","author":"D Grahn","year":"1998","unstructured":"Grahn D, Brock-Utne JG, Watenpaugh DE, Heller HC: Recovery from mild hypothermia can be accelerated by mechanically distending blood vessels in the hand. J Appl Physiol. 1998, 85 (5): 1643-1648.","journal-title":"J Appl Physiol"},{"issue":"3","key":"176_CR20","doi-asserted-by":"publisher","first-page":"972","DOI":"10.1152\/japplphysiol.00093.2005","volume":"99","author":"DA Grahn","year":"2005","unstructured":"Grahn DA, Cao VH, Heller HC: Heat extraction through the palm of one hand improves aerobic exercise endurance in a hot environment. J Appl Physiol. 2005, 99 (3): 972-978. 10.1152\/japplphysiol.00093.2005.","journal-title":"J Appl Physiol"},{"issue":"3","key":"176_CR21","doi-asserted-by":"publisher","first-page":"411","DOI":"10.1249\/01.MSS.0000117133.75146.66","volume":"36","author":"TA Hagobian","year":"2004","unstructured":"Hagobian TA, Jacobs KA, Kiratli BJ, Friedlander AL: Foot cooling reduces exercise-induced hyperthermia in men with spinal cord injury. Med Sci Sports Exerc. 2004, 36 (3): 411-417. 10.1249\/01.MSS.0000117133.75146.66.","journal-title":"Med Sci Sports Exerc"},{"issue":"1","key":"176_CR22","doi-asserted-by":"publisher","first-page":"87","DOI":"10.1139\/h05-107","volume":"30","author":"AR Hsu","year":"2005","unstructured":"Hsu AR, Hagobian TA, Jacobs KA, Attallah H, Friedlander AL: Effects of heat removal through the hand on metabolism and performance during cycling exercise in the heat. Can J Appl Physiol. 2005, 30 (1): 87-104.","journal-title":"Can J Appl Physiol"},{"issue":"5169","key":"176_CR23","doi-asserted-by":"publisher","first-page":"252","DOI":"10.1126\/science.8023144","volume":"265","author":"AD Craig","year":"1994","unstructured":"Craig AD, Bushnell MC: The thermal grill illusion: unmasking the burn of cold pain. Science. 1994, 265 (5169): 252-255. 10.1126\/science.8023144.","journal-title":"Science"},{"key":"176_CR24","first-page":"189","volume":"51","author":"TC Guthrie","year":"1950","unstructured":"Guthrie TC: Visual and motor changes in multiple sclerosis as a result of induced temperature changes. Trans Am Neurol Assoc. 1950, 51: 189-194.","journal-title":"Trans Am Neurol Assoc"},{"issue":"4","key":"176_CR25","doi-asserted-by":"publisher","first-page":"437","DOI":"10.1001\/archneurpsyc.1951.02320040027002","volume":"65","author":"TC Guthrie","year":"1951","unstructured":"Guthrie TC: Visual and motor changes in patients with multiple sclerosis; a result of induced changes in environmental temperature. AMA Arch Neurol Psychiatry. 1951, 65 (4): 437-451.","journal-title":"AMA Arch Neurol Psychiatry"},{"issue":"1","key":"176_CR26","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/0022-510X(94)00248-M","volume":"129","author":"TC Guthrie","year":"1995","unstructured":"Guthrie TC, Nelson DA: Influence of temperature changes on multiple sclerosis: critical review of mechanisms and research potential. J Neurol Sci. 1995, 129 (1): 1-8. 10.1016\/0022-510X(94)00248-M.","journal-title":"J Neurol Sci"},{"issue":"5","key":"176_CR27","doi-asserted-by":"publisher","first-page":"1779","DOI":"10.1152\/japplphysiol.01251.2001","volume":"92","author":"DG Baker","year":"2002","unstructured":"Baker DG: Multiple sclerosis and thermoregulatory dysfunction. J Appl Physiol. 2002, 92 (5): 1779-1780.","journal-title":"J Appl Physiol"},{"issue":"5","key":"176_CR28","doi-asserted-by":"publisher","first-page":"892","DOI":"10.1212\/WNL.57.5.892","volume":"57","author":"EA Beenakker","year":"2001","unstructured":"Beenakker EA, Oparina TI, Hartgring A, Teelken A, Arutjunyan AV, De Keyser J: Cooling garment treatment in MS: clinical improvement and decrease in leukocyte NO production. Neurology. 2001, 57 (5): 892-894.","journal-title":"Neurology"},{"issue":"12","key":"176_CR29","doi-asserted-by":"publisher","first-page":"1955","DOI":"10.1212\/01.WNL.0000070183.30517.2F","volume":"60","author":"SR Schwid","year":"2003","unstructured":"Schwid SR, Petrie MD, Murray R, Leitch J, Bowen J, Alquist A, Pelligrino R, Roberts A, Harper-Bennie J, Milan MD, et al: A randomized controlled study of the acute and chronic effects of cooling therapy for MS. Neurology. 2003, 60 (12): 1955-1960.","journal-title":"Neurology"},{"issue":"5","key":"176_CR30","doi-asserted-by":"publisher","first-page":"1481","DOI":"10.1152\/japplphysiol.00319.2006","volume":"101","author":"M Zhu","year":"2006","unstructured":"Zhu M, Ackerman JJ, Sukstanskii AL, Yablonskiy DA: How the body controls brain temperature: the temperature shielding effect of cerebral blood flow. J Appl Physiol. 2006, 101 (5): 1481-1488. 10.1152\/japplphysiol.00319.2006.","journal-title":"J Appl Physiol"},{"issue":"2","key":"176_CR31","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1152\/ajplegacy.1968.215.2.389","volume":"215","author":"JN Hayward","year":"1968","unstructured":"Hayward JN, Baker MA: Role of cerebral arterial blood in the regulation of brain temperature in the monkey. Am J Physiol. 1968, 215 (2): 389-403.","journal-title":"Am J Physiol"},{"issue":"12","key":"176_CR32","first-page":"1065","volume":"63","author":"MH Ereth","year":"1992","unstructured":"Ereth MH, Lennon RL, Sessler DI: Limited heat transfer between thermal compartments during rewarming in vasoconstricted patients. Aviat Space Environ Med. 1992, 63 (12): 1065-1069.","journal-title":"Aviat Space Environ Med"},{"issue":"4","key":"176_CR33","doi-asserted-by":"publisher","first-page":"870","DOI":"10.1097\/00000542-199504000-00008","volume":"82","author":"A Kurz","year":"1995","unstructured":"Kurz A, Sessler DI, Birnbauer F, Illievich UM, Spiss CK: Thermoregulatory vasoconstriction impairs active core cooling. Anesthesiology. 1995, 82 (4): 870-876. 10.1097\/00000542-199504000-00008.","journal-title":"Anesthesiology"},{"issue":"5","key":"176_CR34","doi-asserted-by":"publisher","first-page":"427","DOI":"10.1097\/00002060-200009000-00004","volume":"79","author":"YT Ku","year":"2000","unstructured":"Ku YT, Montgomery LD, Lee HC, Luna B, Webbon BW: Physiologic and functional responses of MS patients to body cooling. Am J Phys Med Rehabil. 2000, 79 (5): 427-434. 10.1097\/00002060-200009000-00004.","journal-title":"Am J Phys Med Rehabil"},{"issue":"1","key":"176_CR35","doi-asserted-by":"publisher","first-page":"14","DOI":"10.3357\/ASEM.2147.2008","volume":"79","author":"L Mourot","year":"2008","unstructured":"Mourot L, Bouhaddi M, Gandelin E, Cappelle S, Dumoulin G, Wolf JP, Rouillon JD, Regnard J: Cardiovascular autonomic control during short-term thermoneutral and cool head-out immersion. Aviat Space Environ Med. 2008, 79 (1): 14-20. 10.3357\/ASEM.2147.2008.","journal-title":"Aviat Space Environ Med"}],"container-title":["BMC Neurology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/1471-2377-8-14.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/1471-2377-8-14\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/1471-2377-8-14","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,18]],"date-time":"2023-05-18T08:35:59Z","timestamp":1684398959000},"score":1,"resource":{"primary":{"URL":"http:\/\/bmcneurol.biomedcentral.com\/articles\/10.1186\/1471-2377-8-14"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,5,12]]},"references-count":35,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2008,12]]}},"alternative-id":["176"],"URL":"https:\/\/doi.org\/10.1186\/1471-2377-8-14","relation":{},"ISSN":["1471-2377"],"issn-type":[{"value":"1471-2377","type":"electronic"}],"subject":[],"published":{"date-parts":[[2008,5,12]]},"article-number":"14"}}