{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,15]],"date-time":"2026-11-15T10:45:31Z","timestamp":1794739531153,"version":"4.9.1"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2014,2,10]],"date-time":"2014-02-10T00:00:00Z","timestamp":1391990400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Pulm Med"],"published-print":{"date-parts":[[2014,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>Nasal nitric oxide (nNO) levels are very low in primary ciliary dyskinesia (PCD) and it is used as a screening test.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>We assessed the reliability and usability of a hand-held analyser in comparison to a stationary nitric oxide (NO) analyser in 50 participants (15 healthy, 13 PCD, 22 other respiratory diseases; age 6\u201379\u00a0years). Nasal NO was measured using a stationary NO analyser during a breath-holding maneuver, and using a hand-held analyser during tidal breathing, sampling at 2\u00a0ml\/sec or 5\u00a0ml\/sec. The three methods were compared for their specificity and sensitivity as a screen for PCD, their success rate in different age groups, within subject repeatability and acceptability. Correlation between methods was assessed.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>Valid nNO measurements were obtained in 94% of participants using the stationary analyser, 96% using the hand-held analyser at 5\u00a0ml\/sec and 76% at 2\u00a0ml\/sec. The hand-held device at 5\u00a0ml\/sec had excellent sensitivity and specificity as a screening test for PCD during tidal breathing (cut-off of 30\u00a0nL\/min,100% sensitivity, &gt;95% specificity). The cut-off using the stationary analyser during breath-hold was 38\u00a0nL\/min (100% sensitivity, 95% specificity). The stationary and hand-held analyser (5\u00a0ml\/sec) showed reasonable within-subject repeatability(% coefficient of variation\u2009=\u200915).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion<\/jats:title>\n            <jats:p>The hand-held NO analyser provides a promising screening tool for PCD.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1186\/1471-2466-14-18","type":"journal-article","created":{"date-parts":[[2014,2,10]],"date-time":"2014-02-10T06:01:21Z","timestamp":1392012081000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":37,"title":["Validation of a portable nitric oxide analyzer for screening in primary ciliary dyskinesias"],"prefix":"10.1186","volume":"14","author":[{"given":"Amanda","family":"Harris","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Esther","family":"Bhullar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kerry","family":"Gove","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rhiannon","family":"Joslin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jennifer","family":"Pelling","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hazel J","family":"Evans","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Woolf T","family":"Walker","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jane S","family":"Lucas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2014,2,10]]},"reference":[{"key":"470_CR1","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1183\/1025448x.10008310","volume-title":"Orphan Lung Diseases","author":"JS Lucas","year":"2011","unstructured":"Lucas JS, Walker WT, Kuehni CE, Lazor R: Primary ciliary dyskinesia. Orphan Lung Diseases. Edited by: Courdier J-F. 2011, UK: European Respiratory Monograph; European Respiratory Society Publications, 201-217."},{"key":"470_CR2","doi-asserted-by":"publisher","first-page":"1264","DOI":"10.1183\/09031936.00176608","volume":"34","author":"A Barbato","year":"2009","unstructured":"Barbato A, Frischer T, Kuehni CE, Snijders D, Azevedo I, Baktai G, Bartoloni L, Eber E, Escribano A, Haarman E, Hesselmar B, Hogg C, Jorissen M, Lucas J, Nielsen KG, O'Callaghan C, Omran H, Pohunek P, Strippoli MP, Bush A: Primary ciliary dyskinesia: a consensus statement on diagnostic and treatment approaches in children. Eur Respir J. 2009, 34: 1264-1276. 10.1183\/09031936.00176608.","journal-title":"Eur Respir J"},{"key":"470_CR3","doi-asserted-by":"publisher","first-page":"1136","DOI":"10.1136\/adc.2006.096958","volume":"92","author":"A Bush","year":"2007","unstructured":"Bush A, Chodhari R, Collins N, Copeland F, Hall P, Harcourt J, Hariri M, Hogg C, Lucas J, Mitchison HM, O'Callaghan C, Phillips G: Primary ciliary dyskinesia: current state of the art. Arch Dis Child. 2007, 92: 1136-1140. 10.1136\/adc.2006.096958.","journal-title":"Arch Dis Child"},{"key":"470_CR4","doi-asserted-by":"publisher","first-page":"656","DOI":"10.1136\/thx.2007.083147","volume":"62","author":"C O'Callaghan","year":"2007","unstructured":"O'Callaghan C, Chilvers M, Hogg C, Bush A, Lucas J: Diagnosing primary ciliary dyskinesia. Thorax. 2007, 62: 656-657. 10.1136\/thx.2007.083147.","journal-title":"Thorax"},{"key":"470_CR5","doi-asserted-by":"publisher","first-page":"1248","DOI":"10.1183\/09031936.00001010","volume":"36","author":"CE Kuehni","year":"2010","unstructured":"Kuehni CE, Frischer T, Strippoli MP, Maurer E, Bush A, Nielsen KG, Escribano A, Lucas JS, Yiallouros P, Omran H, Eber E, O'Callaghan C, Snijders D, Barbato A: Factors influencing age at diagnosis of primary ciliary dyskinesia in European children. Eur Respir J. 2010, 36: 1248-1258. 10.1183\/09031936.00001010.","journal-title":"Eur Respir J"},{"key":"470_CR6","doi-asserted-by":"publisher","first-page":"1402","DOI":"10.1183\/09031936.99.13614069","volume":"13","author":"B Karadag","year":"1999","unstructured":"Karadag B, James AJ, Gultekin E, Wilson NM, Bush A: Nasal and lower airway level of nitric oxide in children with primary ciliary dyskinesia. Eur Respir J. 1999, 13: 1402-1405. 10.1183\/09031936.99.13614069.","journal-title":"Eur Respir J"},{"key":"470_CR7","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1183\/09031936.03.00305503","volume":"21","author":"T Wodehouse","year":"2003","unstructured":"Wodehouse T, Kharitonov SA, Mackay IS, Barnes PJ, Wilson R, Cole PJ: Nasal nitric oxide measurements for the screening of primary ciliary dyskinesia. Eur Respir J. 2003, 21: 43-47. 10.1183\/09031936.03.00305503.","journal-title":"Eur Respir J"},{"key":"470_CR8","doi-asserted-by":"publisher","first-page":"1024","DOI":"10.1183\/09031936.00176111","volume":"40","author":"WT Walker","year":"2012","unstructured":"Walker WT, Jackson CL, Lackie PM, Hogg C, Lucas JS: Nitric oxide in primary ciliary dyskinesia. Eur Respir J. 2012, 40: 1024-1032. 10.1183\/09031936.00176111.","journal-title":"Eur Respir J"},{"issue":"6","key":"470_CR9","doi-asserted-by":"publisher","first-page":"574","DOI":"10.1513\/AnnalsATS.201305-110OC","volume":"10","author":"MW Leigh","year":"2013","unstructured":"Leigh MW, Hazucha MJ, Chawla KK, Baker BR, Shapiro AJ, Brown DE, Lavange LM, Horton BJ, Qaqish B, Carson JL, Davis SD, Dell SD, Ferkol TW, Atkinson JJ, Olivier KN, Sagel SD, Rosenfeld M, Milla C, Lee HS, Krischer J, Zariwala MA, Knowles MR: Standardizing nasal nitric oxide measurement as a test for primary ciliary dyskinesia. Ann Am Thorac Soc. 2013, 10 (6): 574-581.","journal-title":"Ann Am Thorac Soc"},{"key":"470_CR10","volume-title":"Ann Am Thorac Soc","author":"JS Lucas","year":"2013","unstructured":"Lucas JS, Walker WT: Nitric oxide is an important test in the diagnostic pathway for primary ciliary. Ann Am Thorac Soc. 2013, in press"},{"key":"470_CR11","doi-asserted-by":"publisher","first-page":"1667","DOI":"10.1016\/j.rmed.2008.06.021","volume":"102","author":"JD Boot","year":"2008","unstructured":"Boot JD, de Ridder L, de Kam ML, Calderon C, Mascelli MA, Diamant Z: Comparison of exhaled nitric oxide measurements between NIOX MINO electrochemical and Ecomedics chemiluminescence analyzer. Respir Med. 2008, 102: 1667-1667. 10.1016\/j.rmed.2008.06.021.","journal-title":"Respir Med"},{"key":"470_CR12","doi-asserted-by":"publisher","first-page":"830","DOI":"10.1111\/j.1440-1843.2012.02163.x","volume":"17","author":"SH Kim","year":"2012","unstructured":"Kim SH, Moon JY, Kwak HJ, Kim SI, Park DW, Kim JW, Kim TH, Sohn JW, Shin DH, Park SS, Yoon HJ: Comparison of two exhaled nitric oxide analyzers: the NIOX MINO hand-held electrochemical analyzer and the NOA280i stationary chemiluminescence analyzer. Respirology. 2012, 17: 830-834. 10.1111\/j.1440-1843.2012.02163.x.","journal-title":"Respirology"},{"key":"470_CR13","doi-asserted-by":"publisher","first-page":"679","DOI":"10.1111\/j.1399-3038.2009.00853.x","volume":"20","author":"B Schiller","year":"2009","unstructured":"Schiller B, Hammer J, Barben J, Trachsel D: Comparability of a hand-held nitric oxide analyser with online and offline chemiluminescence-based nitric oxide measurement. Pediatr Allergy Immunol. 2009, 20: 679-685. 10.1111\/j.1399-3038.2009.00853.x.","journal-title":"Pediatr Allergy Immunol"},{"key":"470_CR14","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1186\/1465-9921-11-43","volume":"11","author":"A Selby","year":"2010","unstructured":"Selby A, Clayton B, Grundy J, Pike K, Drew K, Raza A, Kurukulaaratchy R, Arshad SH, Roberts G: Are exhaled nitric oxide measurements using the portable NIOX MINO repeatable?. Respir Res. 2010, 11: 43-10.1186\/1465-9921-11-43.","journal-title":"Respir Res"},{"key":"470_CR15","doi-asserted-by":"publisher","first-page":"197","DOI":"10.1111\/j.1365-2362.2008.01907.x","volume":"38","author":"M Maniscalco","year":"2008","unstructured":"Maniscalco M, de Laurentiis G, Weitzberg E, Lundberg JO, Sofia M: Validation study of nasal nitric oxide measurements using a hand-held electrochemical analyser. Eur J Clin Invest. 2008, 38: 197-200. 10.1111\/j.1365-2362.2008.01907.x.","journal-title":"Eur J Clin Invest"},{"key":"470_CR16","first-page":"23","volume":"46","author":"M Weschta","year":"2008","unstructured":"Weschta M, Deutschle T, Riechelmann H: Nasal fractional exhaled nitric oxide analysis with a novel hand-held device. Rhinology. 2008, 46: 23-27.","journal-title":"Rhinology"},{"key":"470_CR17","doi-asserted-by":"publisher","first-page":"1063","DOI":"10.1111\/j.1365-2362.2011.02501.x","volume":"41","author":"S Montella","year":"2011","unstructured":"Montella S, Alving K, Maniscalco M, Sofia M, De SS, Raia V, Santamaria F: Measurement of nasal nitric oxide by hand-held and stationary devices. Eur J Clin Invest. 2011, 41: 1063-1070. 10.1111\/j.1365-2362.2011.02501.x.","journal-title":"Eur J Clin Invest"},{"key":"470_CR18","doi-asserted-by":"publisher","first-page":"e57262","DOI":"10.1371\/journal.pone.0057262","volume":"8","author":"JK Marthin","year":"2013","unstructured":"Marthin JK, Nielsen KG: Hand-held tidal breathing nasal nitric oxide measurement\u2013a promising targeted case-finding tool for the diagnosis of primary ciliary dyskinesia. PLoS One. 2013, 8: e57262-10.1371\/journal.pone.0057262.","journal-title":"PLoS One"},{"key":"470_CR19","doi-asserted-by":"publisher","first-page":"982","DOI":"10.1183\/09031936.98.12040982","volume":"12","author":"A Bush","year":"1998","unstructured":"Bush A, Cole P, Hariri M, Mackay I, Phillips G, O'Callaghan C, Wilson R, Warner JO: Primary ciliary dyskinesia: diagnosis and standards of care. Eur Respir J. 1998, 12: 982-988. 10.1183\/09031936.98.12040982.","journal-title":"Eur Respir J"},{"issue":"8","key":"470_CR20","doi-asserted-by":"publisher","first-page":"912","DOI":"10.1164\/rccm.200406-710ST","volume":"171","author":"American Thoracic Society; European Respiratory Society","year":"2005","unstructured":"American Thoracic Society; European Respiratory Society: ATS\/ERS recommendations for standardized procedures for the online and offline measurement of exhaled lower respiratory nitric oxide and nasal nitric oxide,2005. Am J Respir Crit Care Med. 2005, 171 (8): 912-30.","journal-title":"Am J Respir Crit Care Med"},{"key":"470_CR21","doi-asserted-by":"publisher","first-page":"420","DOI":"10.1016\/j.jpeds.2011.03.007","volume":"159","author":"D Mateos-Corral","year":"2011","unstructured":"Mateos-Corral D, Coombs R, Grasemann H, Ratjen F, Dell SD: Diagnostic value of nasal nitric oxide measured with non-velum closure techniques for children with primary ciliary dyskinesia. J Pediatr. 2011, 159: 420-424. 10.1016\/j.jpeds.2011.03.007.","journal-title":"J Pediatr"},{"key":"470_CR22","doi-asserted-by":"publisher","first-page":"559","DOI":"10.1183\/09031936.00032610","volume":"37","author":"JK Marthin","year":"2011","unstructured":"Marthin JK, Nielsen KG: Choice of nasal nitric oxide technique as first-line test for primary ciliary dyskinesia. Eur Respir J. 2011, 37: 559-565. 10.1183\/09031936.00032610.","journal-title":"Eur Respir J"},{"key":"470_CR23","doi-asserted-by":"publisher","first-page":"566","DOI":"10.1183\/09031936.00068810","volume":"37","author":"M Pifferi","year":"2011","unstructured":"Pifferi M, Bush A, Caramella D, Di CM, Zangani M, Chinellato I, Macchia P, Boner AL: Agenesis of paranasal sinuses and nasal nitric oxide in primary ciliary dyskinesia. Eur Respir J. 2011, 37: 566-571. 10.1183\/09031936.00068810.","journal-title":"Eur Respir J"}],"container-title":["BMC Pulmonary Medicine"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/1471-2466-14-18.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/1471-2466-14-18\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/1471-2466-14-18","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/1471-2466-14-18.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,9,2]],"date-time":"2021-09-02T02:57:45Z","timestamp":1630551465000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcpulmmed.biomedcentral.com\/articles\/10.1186\/1471-2466-14-18"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,2,10]]},"references-count":23,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2014,12]]}},"alternative-id":["470"],"URL":"https:\/\/doi.org\/10.1186\/1471-2466-14-18","relation":{},"ISSN":["1471-2466"],"issn-type":[{"value":"1471-2466","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,2,10]]},"assertion":[{"value":"9 January 2013","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 February 2014","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 February 2014","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}],"article-number":"18"}}