{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,26]],"date-time":"2026-02-26T19:16:04Z","timestamp":1772133364162,"version":"3.50.1"},"reference-count":19,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2010,9,6]],"date-time":"2010-09-06T00:00:00Z","timestamp":1283731200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/2.0"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"published-print":{"date-parts":[[2010,12]]},"DOI":"10.1186\/1471-2474-11-199","type":"journal-article","created":{"date-parts":[[2010,9,21]],"date-time":"2010-09-21T18:15:02Z","timestamp":1285092902000},"source":"Crossref","is-referenced-by-count":14,"title":["The European multicenter trial on the safety and efficacy of guided oblique lumbar interbody fusion (GO-LIF)"],"prefix":"10.1186","volume":"11","author":[{"given":"Christof","family":"Birkenmaier","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Olaf","family":"Suess","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael","family":"Pfeiffer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ralf","family":"Burger","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kirsten","family":"Schmieder","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bernd","family":"Wegener","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2010,9,6]]},"reference":[{"issue":"2","key":"945_CR1","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1007\/s00586-002-0493-8","volume":"12","author":"P Fritzell","year":"2003","unstructured":"Fritzell P, Hagg O, Nordwall A: Complications in lumbar fusion surgery for chronic low back pain: comparison of three surgical techniques used in a prospective randomized study. A report from the Swedish Lumbar Spine Study Group. Eur Spine J. 2003, 12 (2): 178-189.","journal-title":"Eur Spine J"},{"issue":"6","key":"945_CR2","doi-asserted-by":"publisher","first-page":"594","DOI":"10.1007\/s00586-002-0469-8","volume":"11","author":"PC Jutte","year":"2002","unstructured":"Jutte PC, Castelein RM: Complications of pedicle screws in lumbar and lumbosacral fusions in 105 consecutive primary operations. Eur Spine J. 2002, 11 (6): 594-598. 10.1007\/s00586-002-0469-8.","journal-title":"Eur Spine J"},{"issue":"2","key":"945_CR3","doi-asserted-by":"publisher","first-page":"144","DOI":"10.1097\/00024720-200304000-00005","volume":"16","author":"A Minamide","year":"2003","unstructured":"Minamide A, Akamaru T, Yoon ST, Tamaki T, Rhee JM, Hutton WC: Transdiscal L5-S1 screws for the fixation of isthmic spondylolisthesis: a biomechanical evaluation. J Spinal Disord Tech. 2003, 16 (2): 144-149.","journal-title":"J Spinal Disord Tech"},{"issue":"6","key":"945_CR4","doi-asserted-by":"publisher","first-page":"710","DOI":"10.1097\/00007632-199403001-00011","volume":"19","author":"WA Abdu","year":"1994","unstructured":"Abdu WA, Wilber RG, Emery SE: Pedicular transvertebral screw fixation of the lumbosacral spine in spondylolisthesis. A new technique for stabilization. Spine. 1994, 19 (6): 710-715. 10.1097\/00007632-199403001-00011.","journal-title":"Spine"},{"issue":"1 Suppl","key":"945_CR5","first-page":"105","volume":"95","author":"J Chell","year":"2001","unstructured":"Chell J, Quinnell RC: Transvertebral pedicle fixation in severe grade spondylolisthesis. Report of three cases. J Neurosurg. 2001, 95 (1 Suppl): 105-107.","journal-title":"J Neurosurg"},{"issue":"20","key":"945_CR6","doi-asserted-by":"publisher","first-page":"2227","DOI":"10.1097\/00007632-200110150-00014","volume":"26","author":"JA Smith","year":"2001","unstructured":"Smith JA, Deviren V, Berven S, Kleinstueck F, Bradford DS: Clinical outcome of trans-sacral interbody fusion after partial reduction for high-grade L5-S1 spondylolisthesis. Spine. 2001, 26 (20): 2227-2234. 10.1097\/00007632-200110150-00014.","journal-title":"Spine"},{"issue":"6","key":"945_CR7","doi-asserted-by":"publisher","first-page":"E161","DOI":"10.1097\/00007632-200203150-00019","volume":"27","author":"O Boachie-Adjei","year":"2002","unstructured":"Boachie-Adjei O, Do T, Rawlins BA: Partial lumbosacral kyphosis reduction, decompression, and posterior lumbosacral transfixation in high-grade isthmic spondylolisthesis: clinical and radiographic results in six patients. Spine. 2002, 27 (6): E161-168. 10.1097\/00007632-200203150-00019.","journal-title":"Spine"},{"issue":"11","key":"945_CR8","doi-asserted-by":"publisher","first-page":"1135","DOI":"10.1097\/00007632-200306010-00010","volume":"28","author":"P Bartolozzi","year":"2003","unstructured":"Bartolozzi P, Sandri A, Cassini M, Ricci M: One-stage posterior decompression-stabilization and trans-sacral interbody fusion after partial reduction for severe L5-S1 spondylolisthesis. Spine. 2003, 28 (11): 1135-1141. 10.1097\/00007632-200306010-00010.","journal-title":"Spine"},{"issue":"1 Suppl Spine","key":"945_CR9","first-page":"62","volume":"100","author":"H Bozkus","year":"2004","unstructured":"Bozkus H, Dickman CA: Transvertebral interbody cage and pedicle screw fixation for high-grade spondylolisthesis. Case report. J Neurosurg. 2004, 100 (1 Suppl Spine): 62-65.","journal-title":"J Neurosurg"},{"issue":"3","key":"945_CR10","first-page":"E7","volume":"20","author":"WF Beringer","year":"2006","unstructured":"Beringer WF, Mobasser JP, Karahalios D, Potts EA: Anterior transvertebral interbody cage with posterior transdiscal pedicle screw instrumentation for high-grade spondylolisthesis. Technical note. Neurosurg Focus. 2006, 20 (3): E7-","journal-title":"Neurosurg Focus"},{"issue":"4","key":"945_CR11","doi-asserted-by":"publisher","first-page":"281","DOI":"10.1007\/BF00301335","volume":"5","author":"D Grob","year":"1996","unstructured":"Grob D, Humke T, Dvorak J: Direct pediculo-body fixation in cases of spondylolisthesis with advanced intervertebral disc degeneration. Eur Spine J. 1996, 5 (4): 281-285. 10.1007\/BF00301335.","journal-title":"Eur Spine J"},{"issue":"Suppl 1","key":"945_CR12","doi-asserted-by":"publisher","first-page":"151","DOI":"10.1007\/s00586-009-0997-6","volume":"18","author":"A Zagra","year":"2009","unstructured":"Zagra A, Giudici F, Minoia L, Corriero AS, Zagra L: Long-term results of pediculo-body fixation and posterolateral fusion for lumbar spondylolisthesis. Eur Spine J. 2009, 18 (Suppl 1): 151-155. 10.1007\/s00586-009-0997-6.","journal-title":"Eur Spine J"},{"issue":"3","key":"945_CR13","doi-asserted-by":"publisher","first-page":"641","DOI":"10.1227\/01.NEU.0000229055.00829.5B","volume":"59","author":"IH Lieberman","year":"2006","unstructured":"Lieberman IH, Togawa D, Kayanja MM, Reinhardt MK, Friedlander A, Knoller N, Benzel EC: Bone-mounted miniature robotic guidance for pedicle screw and translaminar facet screw placement: Part I--Technical development and a test case result. Neurosurgery. 2006, 59 (3): 641-650. 10.1227\/01.NEU.0000229055.00829.5B. discussion 641-650","journal-title":"Neurosurgery"},{"issue":"2","key":"945_CR14","doi-asserted-by":"publisher","first-page":"114","DOI":"10.1002\/rcs.86","volume":"2","author":"W Sukovich","year":"2006","unstructured":"Sukovich W, Brink-Danan S, Hardenbrook M: Miniature robotic guidance for pedicle screw placement in posterior spinal fusion: early clinical experience with the SpineAssist. Int J Med Robot. 2006, 2 (2): 114-122.","journal-title":"Int J Med Robot"},{"issue":"4","key":"945_CR15","doi-asserted-by":"publisher","first-page":"392","DOI":"10.1097\/BRS.0b013e318191ed32","volume":"34","author":"I Pechlivanis","year":"2009","unstructured":"Pechlivanis I, Kiriyanthan G, Engelhardt M, Scholz M, Lucke S, Harders A, Schmieder K: Percutaneous placement of pedicle screws in the lumbar spine using a bone mounted miniature robotic system: first experiences and accuracy of screw placement. Spine (Phila Pa 1976). 2009, 34 (4): 392-398.","journal-title":"Spine (Phila Pa 1976)"},{"key":"945_CR16","unstructured":"A Clinical Safety and Feasibility Study of the GO-LIF\u2122 Approach. [ http:\/\/www.clinicaltrials.gov\/ct2\/show\/NCT00810433 ]"},{"issue":"1","key":"945_CR17","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1097\/00007632-199001000-00004","volume":"15","author":"SD Gertzbein","year":"1990","unstructured":"Gertzbein SD, Robbins SE: Accuracy of pedicular screw placement in vivo. Spine (Phila Pa 1976). 1990, 15 (1): 11-14.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"3","key":"945_CR18","doi-asserted-by":"publisher","first-page":"E111","DOI":"10.1097\/01.brs.0000254048.79024.8b","volume":"32","author":"V Kosmopoulos","year":"2007","unstructured":"Kosmopoulos V, Schizas C: Pedicle screw placement accuracy: a meta-analysis. Spine (Phila Pa 1976). 2007, 32 (3): E111-120.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"13","key":"945_CR19","doi-asserted-by":"publisher","first-page":"1743","DOI":"10.1001\/jama.1983.03330370053031","volume":"249","author":"JA Hanley","year":"1983","unstructured":"Hanley JA, Lippman-Hand A: If nothing goes wrong, is everything all right? Interpreting zero numerators. JAMA. 1983, 249 (13): 1743-1745. 10.1001\/jama.249.13.1743.","journal-title":"JAMA"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1186\/1471-2474-11-199\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/1471-2474-11-199.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/1471-2474-11-199","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/1471-2474-11-199.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,6,12]],"date-time":"2020-06-12T00:51:51Z","timestamp":1591923111000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/1471-2474-11-199"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,9,6]]},"references-count":19,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2010,12]]}},"alternative-id":["945"],"URL":"https:\/\/doi.org\/10.1186\/1471-2474-11-199","relation":{},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,9,6]]},"article-number":"199"}}