{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T13:09:47Z","timestamp":1791896987996,"version":"4.3.4"},"reference-count":34,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2010,1,4]],"date-time":"2010-01-04T00:00:00Z","timestamp":1262563200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/2.0"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"published-print":{"date-parts":[[2010,12]]},"DOI":"10.1186\/1471-2474-11-3","type":"journal-article","created":{"date-parts":[[2010,1,5]],"date-time":"2010-01-05T07:15:13Z","timestamp":1262675713000},"source":"Crossref","is-referenced-by-count":199,"title":["Modular titanium alloy neck adapter failures in hip replacement - failure mode analysis and influence of implant material"],"prefix":"10.1186","volume":"11","author":[{"given":"Thomas M","family":"Grupp","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas","family":"Weik","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wilhelm","family":"Bloemer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hanns-Peter","family":"Knaebel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2010,1,4]]},"reference":[{"issue":"1","key":"749_CR1","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1177\/112070000101100101","volume":"11","author":"A Toni","year":"2001","unstructured":"Toni A, Paderni S, Sudanese A, Guerra E, Traina F, Antonietti B, Giunti A: Anatomic cementless total hip arthroplasty with ceramic bearings and modular necks: 3 to 5 years follow-up. Hip International. 2001, 11 (1): 1-17.","journal-title":"Hip International"},{"key":"749_CR2","volume-title":"Scientific Exhibit at the 71st AAOS Annual Meeting, San Francisco","author":"F Traina","year":"2004","unstructured":"Traina F, Baleani M, Viceconti M, Toni A: Modular Neck Primary Prosthesis: Experimental and Clinical Outcomes. Scientific Exhibit at the 71st AAOS Annual Meeting, San Francisco. 2004"},{"key":"749_CR3","first-page":"73","volume":"LXXXVI","author":"A Toni","year":"2001","unstructured":"Toni A, Sudanese A, Paderni S, Guerra E, Bianchi G, Antonietti B, Giunti A: Artroprotesi d'anca non cementata con collo modulare - Cementless hip arthroplasty with a modular neck. Chir Organi Mov. 2001, LXXXVI: 73-85.","journal-title":"Chir Organi Mov"},{"issue":"Suppl 10","key":"749_CR4","first-page":"144","volume":"30","author":"A Braun","year":"2007","unstructured":"Braun A, Lazovic D, Zigan R: Modular short stem prosthesis- Implant positioning and the impact of navigation. Orthopedics Suppl. 2007, 30 (Suppl 10): 144-147.","journal-title":"Orthopedics Suppl"},{"key":"749_CR5","first-page":"16","volume-title":"Symposium \"Cutting-edge developments on proximal modularity in THA\" Annual AAHKS Meeting","author":"KJ Keggi","year":"2008","unstructured":"Keggi KJ: My experience with proximal modular stems. Symposium \"Cutting-edge developments on proximal modularity in THA\" Annual AAHKS Meeting. 2008, 16-22."},{"issue":"2","key":"749_CR6","doi-asserted-by":"publisher","first-page":"124","DOI":"10.1097\/BCO.0b013e3282f53eca","volume":"19","author":"KJ Keggi","year":"2008","unstructured":"Keggi KJ, Kennon RE, Keggi JM: Hip reconstruction - primary total hip arthroplasty with modular stems. Current Orthopaedic Practice. 2008, 19 (2): 124-126. 10.1097\/BCO.0b013e3282f53eca.","journal-title":"Current Orthopaedic Practice"},{"key":"749_CR7","volume-title":"Abstract, Australian Orthopaedic Association 67th Annual Scientific Meeting","author":"HU Cameron","year":"2007","unstructured":"Cameron HU, Leslie CJ, McTighe T: Design considerations and results for a modular neck in cemented THA. Abstract, Australian Orthopaedic Association 67th Annual Scientific Meeting. 2007"},{"key":"749_CR8","first-page":"12","volume-title":"Metha short stem hip prosthesis - Examination of the modular cone connection","author":"T Hermle","year":"2007","unstructured":"Hermle T, Zeller R, Grupp TM, Bl\u00f6mer W: Metha short stem hip prosthesis - Examination of the modular cone connection. 2007, Springer Medizin Verlag, Heidelberg, implant, 12-17. 1\/07"},{"key":"749_CR9","doi-asserted-by":"crossref","unstructured":"Bobyn JD, Tanzer M, Krygier JJ, Dujovne AR, Brooks CE: Concerns with modularity in total hip arthroplasty. Clin Orth Rel Res. 1994, 27-38. 298","DOI":"10.1097\/00003086-199401000-00006"},{"issue":"1","key":"749_CR10","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1002\/jab.770060104","volume":"6","author":"SA Brown","year":"1995","unstructured":"Brown SA, Flemming CA, Kawalec JS, Placko HE, Vassaux C, Merritt K, Payer JH, Kraay MJ: Fretting corrosion accelerates crevice corrosion of modular hip tapers. J Appl Biomater. 1995, 6 (1): 19-26. 10.1002\/jab.770060104.","journal-title":"J Appl Biomater"},{"key":"749_CR11","doi-asserted-by":"crossref","unstructured":"Lieberman JR, Rimnac CM, Garvin KL, Klein RW, Salvati EA: An analysis of the head-neck taper interface in retrieved hip prostheses. Clin Orth Rel Res. 1994, 162-167. 300","DOI":"10.1097\/00003086-199403000-00021"},{"key":"749_CR12","first-page":"1533","volume":"27","author":"JL Gilbert","year":"1993","unstructured":"Gilbert JL, Buckley CA, Jacobs JJ: In vivo corrosion of modular hip prosthesis components in mixed and similar metal combinations. The effect of crevice, stress, motion, and alloy coupling. Journal of Biomedical Materials Research. 1993, 27: 1533-1544.","journal-title":"The effect of crevice, stress, motion, and alloy coupling. Journal of Biomedical Materials Research"},{"key":"749_CR13","doi-asserted-by":"crossref","unstructured":"Goldberg JR, Gilbert JL, Jacobs JJ, Bauer TW, Paprosky W, Leurgans S: A multicenter retrieval study of the taper interfaces of modular hip prostheses. Clin Orth Rel Res. 2002, 149-161. 10.1097\/00003086-200208000-00018. 401","DOI":"10.1097\/00003086-200208000-00018"},{"key":"749_CR14","volume-title":"Dissertation Eidgen\u00f6ssisch TechnischeHochschule Z\u00fcrich No. 15284","author":"M Windler","year":"2003","unstructured":"Windler M: Korrosionsverhalten von modularen Verbindungen bei H\u00fcftprothesen. Dissertation Eidgen\u00f6ssisch TechnischeHochschule Z\u00fcrich No. 15284. 2003"},{"key":"749_CR15","doi-asserted-by":"crossref","unstructured":"Collier JP, Surprenant VA, Jensen RE, Mayor MB: Corrosion at the interface of cobalt-alloy heads on titanium-alloy stems. Clin Orth Rel Res. 1991, 305-312. 271","DOI":"10.1097\/00003086-199110000-00042"},{"issue":"3","key":"749_CR16","doi-asserted-by":"publisher","first-page":"291","DOI":"10.1016\/0883-5403(92)90051-Q","volume":"7","author":"H McKellop","year":"1992","unstructured":"McKellop H, Sarmiento A, Brien W, Park SH: Interface corrosion of a modular head total hip prosthesis. J Arthroplasty. 1992, 7 (3): 291-294. 10.1016\/0883-5403(92)90051-Q.","journal-title":"J Arthroplasty"},{"key":"749_CR17","doi-asserted-by":"crossref","first-page":"268","DOI":"10.2106\/00004623-199802000-00015","volume":"80-A","author":"JJ Jacobs","year":"1998","unstructured":"Jacobs JJ, Gilbert JL, Urban RM: Current concepts review - Corrosion of metal orthopaedic implants. J Bone Joint Surg [Am]. 1998, 80-A: 268-282.","journal-title":"J Bone Joint Surg [Am]"},{"key":"749_CR18","volume-title":"Study to determine the relative motion between the neck adapter and the stem Biomechanics Section - Hamburg University of Technology, Aesculap test report No. V1039","author":"E Hoenig","year":"2008","unstructured":"Hoenig E, Morlock MM: \"Bestimmung der Relativbewegung an der Konusverbindung der modularen Metha-Kurzschaftprothese\". Study to determine the relative motion between the neck adapter and the stem Biomechanics Section - Hamburg University of Technology, Aesculap test report No. V1039. 2008"},{"key":"749_CR19","volume-title":"Abstract Orthopedic Research Society, Las Vegas, Nevada","author":"E Hoenig","year":"2009","unstructured":"Hoenig E, Morlock MM: Estimation of the relative motion in the taper lock interface of a modular hip prosthesis. Abstract Orthopedic Research Society, Las Vegas, Nevada. 2009"},{"key":"749_CR20","doi-asserted-by":"publisher","first-page":"274","DOI":"10.1007\/978-3-662-11502-2","volume-title":"Die Korrosion der Metalle - Physikalisch-chemische Prinzipien und aktuelle Probleme","author":"H Kaesche","year":"1979","unstructured":"Kaesche H: Die Korrosion der Metalle - Physikalisch-chemische Prinzipien und aktuelle Probleme. 1979, Springer-Verlag Berlin Heidelberg New York, 274-276."},{"key":"749_CR21","first-page":"45","volume-title":"Modularity of orthopedic implants, ASTM STP 1301","author":"JL Gilbert","year":"1997","unstructured":"Gilbert JL, Jacobs JJ: The mechanical and electrochemical processes associated with taper fretting crevice corrosion - a review. Modularity of orthopedic implants, ASTM STP 1301. Edited by: Parr JE, Mayor MB. 1997, J ASTM International, 45-59. full_text."},{"key":"749_CR22","first-page":"1","volume-title":"Corrosion of modular titanium alloy stems in cementless hip replacement","author":"RM Urban","year":"2005","unstructured":"Urban RM, Gilbert JL, Jacobs JJ: Corrosion of modular titanium alloy stems in cementless hip replacement. 2005, J ASTM International, 2 (10): 1-10."},{"issue":"1","key":"749_CR23","doi-asserted-by":"publisher","first-page":"206","DOI":"10.1002\/jbm.b.31171","volume":"88B","author":"DC Rodrigues","year":"2009","unstructured":"Rodrigues DC, Urban RM, Jacobs JJ, Gilbert JL: In vivo severe corrosion and hydrogen embrittlement of retrieved modular body titanium alloy hip-implants. J Biomed Mater Res Part B Appl Biomater. 2009, 88B (1): 206-219. 10.1002\/jbm.b.31171.","journal-title":"J Biomed Mater Res Part B Appl Biomater"},{"key":"749_CR24","doi-asserted-by":"crossref","first-page":"511","DOI":"10.1302\/0301-620X.74B4.1624507","volume":"74-B","author":"JP Collier","year":"1992","unstructured":"Collier JP, Surprenant VA, Jensen RE, Mayor MB, Surprenant HP: Corrosion between the components of modular femoral hip prostheses. J Bone Joint Surg [Br]. 1992, 74-B: 511-517.","journal-title":"J Bone Joint Surg [Br]"},{"key":"749_CR25","doi-asserted-by":"crossref","unstructured":"Cook SD, Barrack RL, Baffes GC, Clemow AJT, Serekian P, Dong N, Kester MA: Wear and corrosion of modular interfaces in total hip replacements. Clin Orth Rel Res. 1994, 80-88. 298","DOI":"10.1097\/00003086-199401000-00013"},{"key":"749_CR26","first-page":"157","volume-title":"Modularity of orthopedic implants, ASTM STP 1301","author":"JR Goldberg","year":"1997","unstructured":"Goldberg JR, Buckley CA, Jacobs JJ, Gilbert JL: Corrosion testing of modular hip implants. Modularity of orthopedic implants, ASTM STP 1301. Edited by: Parr JE, Mayor MB. 1997, J ASTM International, 157-176. full_text."},{"key":"749_CR27","doi-asserted-by":"publisher","first-page":"78","DOI":"10.1002\/jbm.b.10526","volume":"64B","author":"JR Goldberg","year":"2003","unstructured":"Goldberg JR, Gilbert JL: In vitro corrosion testing of modular hip tapers. J Biomed Mater Res Part B: Appl Biomater. 2003, 64B: 78-93. 10.1002\/jbm.b.10526.","journal-title":"J Biomed Mater Res Part B: Appl Biomater"},{"key":"749_CR28","doi-asserted-by":"publisher","first-page":"805","DOI":"10.1016\/S0043-1648(03)00522-2","volume":"256","author":"L Duisabeau","year":"2004","unstructured":"Duisabeau L, Combrade P, Forest B: Environmental effect on fretting of metallic materials for orthopaedic implants. Wear. 2004, 256: 805-816. 10.1016\/S0043-1648(03)00522-2.","journal-title":"Wear"},{"key":"749_CR29","first-page":"155","volume-title":"Fretting Fatigue Consideration in Engineering Design, Wear","author":"DW Hoeppner","year":"1981","unstructured":"Hoeppner DW, Gates FL: Fretting Fatigue Consideration in Engineering Design, Wear. 1981, 70: 155-164."},{"key":"749_CR30","doi-asserted-by":"publisher","first-page":"207","DOI":"10.1002\/(SICI)1097-4636(199705)35:2<207::AID-JBM9>3.0.CO;2-R","volume":"35","author":"M Viceconti","year":"1997","unstructured":"Viceconti M, Baleani M, Squarzoni S, Toni A: Fretting wear in modular neck hip prosthesis. Journal of Biomedical Materials Research. 1997, 35: 207-216. 10.1002\/(SICI)1097-4636(199705)35:2<207::AID-JBM9>3.0.CO;2-R.","journal-title":"Journal of Biomedical Materials Research"},{"key":"749_CR31","doi-asserted-by":"publisher","first-page":"181","DOI":"10.1002\/(SICI)1097-4636(199602)30:2<181::AID-JBM7>3.0.CO;2-N","volume":"30","author":"M Viceconti","year":"1996","unstructured":"Viceconti M, Ruggeri O, Toni A, Giunti A: Design-related fretting wear in modular neck hip prosthesis. Journal of Biomedical Materials Research. 1996, 30: 181-186. 10.1002\/(SICI)1097-4636(199602)30:2<181::AID-JBM7>3.0.CO;2-N.","journal-title":"Journal of Biomedical Materials Research"},{"key":"749_CR32","first-page":"189","volume-title":"Fretting in orthopaedic implants: a review, Wear","author":"DW Hoeppner","year":"1994","unstructured":"Hoeppner DW, Chandrasekaran V: Fretting in orthopaedic implants: a review, Wear. 1994, 173: 189-197."},{"key":"749_CR33","doi-asserted-by":"publisher","first-page":"3385","DOI":"10.1007\/s11661-005-0012-8","volume":"36A","author":"SA Martinez","year":"2005","unstructured":"Martinez SA, Sathish S, Mall S, Blodgett MP: Evolution of fretting fatigue damage and relaxation of residual stress in shot-peened Ti6Al4V. Metallurgical and Materials Trans A. 2005, 36A: 3385-3396. 10.1007\/s11661-005-0012-8.","journal-title":"Metallurgical and Materials Trans A"},{"key":"749_CR34","unstructured":"Forschungskuratorium Maschinenbau EV: Reibkorrosion - Vorhaben Nr. 6. Maschinenbau-Verlag GmbH, 6000 Frankfurt\/M, Forschungsheft. 1976, 110-113. 56"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1186\/1471-2474-11-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/1471-2474-11-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/1471-2474-11-3","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/1471-2474-11-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,24]],"date-time":"2019-05-24T22:33:17Z","timestamp":1558737197000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/1471-2474-11-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,1,4]]},"references-count":34,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2010,12]]}},"alternative-id":["749"],"URL":"https:\/\/doi.org\/10.1186\/1471-2474-11-3","relation":{},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,1,4]]},"article-number":"3"}}