{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,23]],"date-time":"2026-01-23T12:10:28Z","timestamp":1769170228543,"version":"3.49.0"},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2013,9,18]],"date-time":"2013-09-18T00:00:00Z","timestamp":1379462400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"published-print":{"date-parts":[[2013,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Background<\/jats:title><jats:p>Spinal systems that are currently available for correction of spinal deformities or degeneration such as lumbar spondylolisthesis or degenerative disc disease use components manufactured from stainless steel or titanium and typically comprise two spinal rods with associated connection devices (for example: DePuy Spines Titanium Moss Miami Spinal System). The Memory Metal Spinal System of this study consists of a single square spinal rod made of a nickel titanium alloy (Nitinol) used in conjunction with connecting transverse bridges and pedicle screws made of Ti-alloy. Nitinol is best known for its shape memory effect, but is also characterized by its higher flexibility when compared to either stainless steel or titanium. A higher fusion rate with less degeneration of adjacent segments may result because of the elastic properties of the memory metal. In addition, the use of a single, unilateral rod may be of great value for a TLIF procedure. Our objective is to evaluate the mechanical properties of the new Memory Metal Spinal System compared to the Titanium Moss Miami Spinal System.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>An in-vitro mechanical evaluation of the lumbar Memory Metal Spinal System was conducted. The test protocol followed ASTM Standard F1717-96, \u201cStandard Test Methods for Static and Fatigue for Spinal Implant Constructs in a Corpectomy Model.\u201d<\/jats:p><jats:p><jats:list list-type=\"order\"><jats:list-item><jats:p>Static axial testing in a load to failure mode in compression bending,<\/jats:p><\/jats:list-item><jats:list-item><jats:p>Static testing in a load to failure mode in torsion,<\/jats:p><\/jats:list-item><jats:list-item><jats:p>Cyclical testing to estimate the maximum run out load value at 5.0 x 10^6\u00a0cycles.<\/jats:p><\/jats:list-item><\/jats:list><\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>In the biomechanical testing for static axial compression bending there was no statistical difference between the 2% yield strength and the stiffness of the two types of spinal constructs.<\/jats:p><jats:p>In axial compression bending fatigue testing, the Memory Metal Spinal System construct showed a 50% increase in fatigue life compared to the Titanium Moss Miami Spinal System.<\/jats:p><jats:p>In static torsional testing the Memory Metal Spinal System constructs showed an average 220% increase in torsional yield strength, and an average 30% increase in torsional stiffness.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>The in-vitro mechanical evaluation of the lumbar Memory Metal Spinal System showed good results when compared to a currently available spinal implant system. Throughout testing, the Memory Metal Spinal System showed no failures in static and dynamic fatigue.<\/jats:p><\/jats:sec>","DOI":"10.1186\/1471-2474-14-269","type":"journal-article","created":{"date-parts":[[2013,9,18]],"date-time":"2013-09-18T18:14:01Z","timestamp":1379528041000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":19,"title":["A new lumbar posterior fixation system, the memory metal spinal system: an in-vitro mechanical evaluation"],"prefix":"10.1186","volume":"14","author":[{"given":"Dennis","family":"Kok","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paul John","family":"Firkins","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Frits H","family":"Wapstra","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Albert G","family":"Veldhuizen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2013,9,18]]},"reference":[{"key":"1931_CR1","first-page":"604","volume":"48","author":"RA Hibbs","year":"1929","unstructured":"Hibbs RA, Swift W: Developmental abnormalities at the lumbosacral juncture causing pain and disability. Surg Gynecol Obstet. 1929, 48: 604-612.","journal-title":"Surg Gynecol Obstet"},{"key":"1931_CR2","volume-title":"Clinical biomechanics of the spine","author":"AA White","year":"1978","unstructured":"White AA, Panjabi M: Clinical biomechanics of the spine. 1978, Philadelphia: JB Lippincott"},{"key":"1931_CR3","first-page":"86","volume-title":"Instumented spinal fusion","author":"KP Schulitz","year":"1994","unstructured":"Schulitz KP: Lumbar spine fusion-indication under special consideration of spinal instrumentation. Instumented spinal fusion. Edited by: Wittenberg RH, Steffen R. 1994, Stuttgart, New York: Georg Thieme Verlag, 86-106."},{"key":"1931_CR4","first-page":"51","volume":"27","author":"RB Cloward","year":"1963","unstructured":"Cloward RB: Lesions of the intervertebral disks and their treatment by interbody fusion methods. Clin Orthop. 1963, 27: 51-77.","journal-title":"Clin Orthop"},{"key":"1931_CR5","doi-asserted-by":"publisher","first-page":"154","DOI":"10.3171\/jns.1953.10.2.0154","volume":"10","author":"RB Cloward","year":"1953","unstructured":"Cloward RB: Rationing the treatment of ruptured lumbar intervertebral discs by vertebral body fusion. J Neurosurg. 1953, 10: 154-168.","journal-title":"J Neurosurg"},{"key":"1931_CR6","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1097\/00003086-198101000-00013","volume":"154","author":"RB Cloward","year":"1981","unstructured":"Cloward RB: Spondylolisthesis: treatment by laminectomy and posterior lumbar interbody fusion. Clin Orthop. 1981, 154: 74-82.","journal-title":"Clin Orthop"},{"key":"1931_CR7","volume-title":"Posterior lumbar interbody fusion (P.L.I.F.) surgical techniques","author":"RB Cloward","year":"1990","unstructured":"Cloward RB: Posterior lumbar interbody fusion (P.L.I.F.) surgical techniques. 1990, Randolph, MA, USA: Codman"},{"key":"1931_CR8","doi-asserted-by":"publisher","first-page":"1129","DOI":"10.1097\/00007632-198810000-00013","volume":"13","author":"MM Panjabi","year":"1988","unstructured":"Panjabi MM: Biomechanical evaluation of spinal fixation devices: I a conceptual framework. Spine. 1988, 13: 1129-1134.","journal-title":"Spine"},{"key":"1931_CR9","doi-asserted-by":"publisher","first-page":"99","DOI":"10.1097\/00002517-199304000-00002","volume":"6","author":"K-Y Ha","year":"1993","unstructured":"Ha K-Y, Schendel MJ, Lewis JL, et al.: Effects of immobilization and configuration on lumbar adjacent-segment biomechanics. J Spinal Disord. 1993, 6: 99-105.","journal-title":"J Spinal Disord"},{"key":"1931_CR10","doi-asserted-by":"publisher","first-page":"574","DOI":"10.1097\/00007632-198409000-00007","volume":"9","author":"CK Lee","year":"1984","unstructured":"Lee CK, Langrana NA: Lumbosacral spinal fusion: a biomechanical study. Spine. 1984, 9: 574-581.","journal-title":"Spine"},{"key":"1931_CR11","doi-asserted-by":"publisher","first-page":"2471","DOI":"10.1097\/00007632-199312000-00017","volume":"18","author":"H Nagata","year":"1993","unstructured":"Nagata H, Schendel MJ, Transfeldt EE, et al.: The effects of immobilization of long segments of the spine on the adjacent and distal facet force and lumbosacral motion. Spine. 1993, 18: 2471-2479.","journal-title":"Spine"},{"key":"1931_CR12","doi-asserted-by":"publisher","first-page":"1550","DOI":"10.1097\/00007632-199807150-00009","volume":"23","author":"Y Shono","year":"1998","unstructured":"Shono Y, Kaneda K, Abumi K, et al.: Stability of posterior spinal instrumentation and its effects on adjacent motion segments in the lumbosacral spine. Spine. 1998, 23: 1550-1558.","journal-title":"Spine"},{"issue":"2","key":"1931_CR13","doi-asserted-by":"publisher","first-page":"171","DOI":"10.1016\/S1350-4533(96)00049-5","volume":"19","author":"AG Veldhuizen","year":"1997","unstructured":"Veldhuizen AG, Sanders MM, Cool JC: A scoliosis correction device based on memory metal. Medical Engineering Physics. 1997, 19 (2): 171-179.","journal-title":"Medical Engineering Physics"},{"key":"1931_CR14","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1097\/00002517-199203000-00006","volume":"5","author":"MB Kabins","year":"1992","unstructured":"Kabins MB, Weinstein JN, Spratt KF, et al.: Isolated L4-L5 fusions using the variable screw placement system: unilateral versus bilateral. J Spinal Disord. 1992, 5: 39-49.","journal-title":"J Spinal Disord"},{"key":"1931_CR15","doi-asserted-by":"publisher","first-page":"1843","DOI":"10.1097\/00007632-200007150-00017","volume":"25","author":"KS Suk","year":"2000","unstructured":"Suk KS, Lee HM, Kim NH, et al.: Unilateral versus bilateral pedicle screw fixation in lumbar spinal fusion. Spine. 2000, 25: 1843-1847.","journal-title":"Spine"},{"key":"1931_CR16","first-page":"105","volume":"1","author":"WJ Buehler","year":"1968","unstructured":"Buehler WJ, Wang FE: A summary of recent research on nitinol alloys and their potential application. Ocean. 1968, 1: 105-120.","journal-title":"Ocean"},{"key":"1931_CR17","doi-asserted-by":"publisher","first-page":"528","DOI":"10.1016\/0002-9416(80)90303-6","volume":"78","author":"G Andreasen","year":"1980","unstructured":"Andreasen G: A clinical trial of alignment of teeth using 0.019 inch thermal Nitinol wire with transitional temperature range between 31 degrees C. and 45 degrees C. Am J Orthop. 1980, 78: 528-537.","journal-title":"Am J Orthop"},{"key":"1931_CR18","first-page":"123","volume":"40","author":"G Bensman","year":"1982","unstructured":"Bensman G, Baumgart F, Haaster J: Osteosyntheseklammern aus nickel titan: herstelung, versuche und klinischer einsatz. Tech Mitt Forsch Ber. 1982, 40: 123-134.","journal-title":"Tech Mitt Forsch Ber"},{"key":"1931_CR19","doi-asserted-by":"publisher","first-page":"775","DOI":"10.1148\/radiology.189.3.8234703","volume":"189","author":"AH Cragg","year":"1993","unstructured":"Cragg AH, De Jong SC, Barnhart WH, Landas SK, Smith TP: Nitinol intra-vascular stent: results of preclinical evaluation. Radiology. 1993, 189: 775-778.","journal-title":"Radiology"},{"key":"1931_CR20","first-page":"487","volume":"11","author":"H Kambic","year":"1988","unstructured":"Kambic H, Sutton C, Oku T, Sugita Y, Murabayashi S, Harasaki H, Kasick J, Shirey E, Nose Y: Biological performance of TiNi shape memory alloy vascular ring protheses: a two year study. Int J Artif Organs. 1988, 11: 487-492.","journal-title":"Int J Artif Organs"},{"key":"1931_CR21","doi-asserted-by":"publisher","first-page":"249","DOI":"10.1097\/00004424-198804000-00009","volume":"23","author":"MR Prince","year":"1988","unstructured":"Prince MR, Salzman EW, Schoen FJ, Palestrant AM, Simon M: Local intravascular effect of the nitinol blood clot filter. Invest Radiol. 1988, 23: 249-300.","journal-title":"Invest Radiol"},{"key":"1931_CR22","doi-asserted-by":"publisher","first-page":"99","DOI":"10.1148\/radiology.172.1.2662259","volume":"172","author":"M Simon","year":"1989","unstructured":"Simon M, Athanasoulis CA, Kim D, Steinberg FL, Porter DH, Byse BH, Kleshinsky S, Geller S, Orron DE, Waltman AC: Simon nitinol inferior vena cava filter: initial clinical experience: work in progress. Radiology. 1989, 172: 99-103.","journal-title":"Radiology"},{"key":"1931_CR23","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/S0142-9612(97)00041-0","volume":"18","author":"DJ Wever","year":"1997","unstructured":"Wever DJ, Veldhuizen AG, Sanders MM, et al.: Cytotoxic, allergic and genotoxic activity of a nickel-titanium alloy. Biomaterials. 1997, 18: 1-6.","journal-title":"Biomaterials"},{"key":"1931_CR24","volume-title":"Standard test methods for spinal implant constructs in a corpectomy model","author":"ASTM International","year":"1996","unstructured":"ASTM International: Standard test methods for spinal implant constructs in a corpectomy model. 1996, West Conshohocken, PA: ASTM Standard F1717, 10.1520\/F1717-96, http:\/\/www.astm.org"},{"key":"1931_CR25","doi-asserted-by":"publisher","first-page":"904","DOI":"10.1097\/BRS.0b013e3181f2d10e","volume":"14","author":"PO Newton","year":"2011","unstructured":"Newton PO, Farnsworth CL, Upasani VV, et al.: Dual and single memory rod construct comparison in an animal study. Spine. 2011, 14: 904-913.","journal-title":"Spine"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/1471-2474-14-269.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/1471-2474-14-269\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/1471-2474-14-269","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/1471-2474-14-269.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,3,6]],"date-time":"2022-03-06T10:46:48Z","timestamp":1646563608000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/1471-2474-14-269"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,9,18]]},"references-count":25,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2013,12]]}},"alternative-id":["1931"],"URL":"https:\/\/doi.org\/10.1186\/1471-2474-14-269","relation":{},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,9,18]]},"assertion":[{"value":"17 January 2013","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 September 2013","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 September 2013","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}],"article-number":"269"}}