{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,10]],"date-time":"2026-07-10T18:21:10Z","timestamp":1783707670607,"version":"3.55.0"},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2007,3,10]],"date-time":"2007-03-10T00:00:00Z","timestamp":1173484800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"published-print":{"date-parts":[[2007,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>Lumbosacral fusion is a relatively common procedure that is used in the management of an unstable spine. The anterior interbody cage has been involved to enhance the stability of a pedicle screw construct used at the lumbosacral junction. Biomechanical differences between polyaxial and monoaxial pedicle screws linked with various rod contours were investigated to analyze the respective effects on overall construct stiffness, cage strain, rod strain, and contact ratios at the vertebra-cage junction.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>A synthetic model composed of two ultrahigh molecular weight polyethylene blocks was used with four titanium pedicle screws (two in each block) and two rods fixation to build the spinal construct along with an anterior interbody cage support. For each pair of the construct fixed with polyaxial or monoaxial screws, the linked rods were set at four configurations to simulate 0\u00b0, 7\u00b0, 14\u00b0, and 21\u00b0 lordosis on the sagittal plane, and a compressive load of 300 N was applied. Strain gauges were attached to the posterior surface of the cage and to the central area of the left connecting rod. Also, the contact area between the block and the cage was measured using prescale Fuji super low pressure film for compression, flexion, lateral bending and torsion tests.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>Our main findings in the experiments with an anterior interbody cage support are as follows: 1) large segmental lordosis can decrease the stiffness of monoaxial pedicle screws constructs; 2) polyaxial screws rather than monoaxial screws combined with the cage fixation provide higher compression and flexion stiffness in 21\u00b0 segmental lordosis; 3) polyaxial screws enhance the contact surface of the cage in 21\u00b0 segmental lordosis.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion<\/jats:title>\n            <jats:p>Polyaxial screws system used in conjunction with anterior cage support yields higher contact ratio, compression and flexion stiffness of spinal constructs than monoaxial screws system does in the same model when the spinal segment is set at large lordotic angles. Polyaxial pedicle screw fixation performs nearly equal percentages of vertebra-cage contact among all constructs with different sagittal alignments, therefore enhances the stabilization effect of interbody cages in the lumbosacral area.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1186\/1471-2474-8-28","type":"journal-article","created":{"date-parts":[[2007,3,10]],"date-time":"2007-03-10T19:01:37Z","timestamp":1173553297000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":17,"title":["Biomechanical effects of polyaxial pedicle screw fixation on the lumbosacral segments with an anterior interbody cage support"],"prefix":"10.1186","volume":"8","author":[{"given":"Shih-Hao","family":"Chen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ruey","family":"Mo Lin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hsiang-Ho","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kai-Jow","family":"Tsai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2007,3,10]]},"reference":[{"key":"305_CR1","first-page":"120","volume-title":"Clin Orthop Relat Res","author":"JW Ogilvie","year":"1986","unstructured":"Ogilvie JW, Schendel M: Comparison of lumbosacral fixation devices. Clin Orthop Relat Res. 1986, 120-125."},{"issue":"16","key":"305_CR2","doi-asserted-by":"publisher","first-page":"1721","DOI":"10.1097\/00007632-199808150-00002","volume":"23","author":"JP Kostuik","year":"1998","unstructured":"Kostuik JP, Valdevit A, Chang HG, Kanzaki K: Biomechanical testing of the lumbosacral spine. Spine. 1998, 23 (16): 1721-1728. 10.1097\/00007632-199808150-00002.","journal-title":"Spine"},{"issue":"2","key":"305_CR3","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1097\/00002517-199106000-00002","volume":"4","author":"O Boachie-Adjei","year":"1991","unstructured":"Boachie-Adjei O, Dendrinos GK, Ogilvie JW, Bradford DS: Management of adult spinal deformity with combined anterior-posterior arthrodesis and Luque-Galveston instrumentation. J Spinal Disord. 1991, 4 (2): 131-141.","journal-title":"J Spinal Disord"},{"issue":"1","key":"305_CR4","first-page":"1","volume":"4","author":"VJ Devlin","year":"1991","unstructured":"Devlin VJ, Boachie-Adjei O, Bradford DS, Ogilvie JW, Transfeldt EE: Treatment of adult spinal deformity with fusion to the sacrum using CD instrumentation. J Spinal Disord. 1991, 4 (1): 1-14.","journal-title":"J Spinal Disord"},{"issue":"6","key":"305_CR5","doi-asserted-by":"publisher","first-page":"594","DOI":"10.1007\/s00586-002-0469-8","volume":"11","author":"PC Jutte","year":"2002","unstructured":"Jutte PC, Castelein RM: Complications of pedicle screws in lumbar and lumbosacral fusions in 105 consecutive primary operations. Eur Spine J. 2002, 11 (6): 594-598. 10.1007\/s00586-002-0469-8.","journal-title":"Eur Spine J"},{"issue":"10","key":"305_CR6","doi-asserted-by":"publisher","first-page":"1211","DOI":"10.1097\/00007632-199605150-00015","volume":"21","author":"PA Glazer","year":"1996","unstructured":"Glazer PA, Colliou O, Lotz JC, Bradford DS: Biomechanical analysis of lumbosacral fixation. Spine. 1996, 21 (10): 1211-1222. 10.1097\/00007632-199605150-00015.","journal-title":"Spine"},{"issue":"9","key":"305_CR7","doi-asserted-by":"publisher","first-page":"1213","DOI":"10.1097\/00007632-199307000-00015","volume":"18","author":"JW Brantigan","year":"1993","unstructured":"Brantigan JW, Cunningham BW, Warden K, McAfee PC, Steffee AD: Compression strength of donor bone for posterior lumbar interbody fusion. Spine. 1993, 18 (9): 1213-1221. 10.1097\/00007632-199307000-00015.","journal-title":"Spine"},{"issue":"11","key":"305_CR8","doi-asserted-by":"publisher","first-page":"1267","DOI":"10.1097\/00007632-199806010-00019","volume":"23","author":"SD Kuslich","year":"1998","unstructured":"Kuslich SD, Ulstrom CL, Griffith SL, Ahern JW, Dowdle JD: The Bagby and Kuslich method of lumbar interbody fusion. History, techniques, and 2-year follow-up results of a United States prospective, multicenter trial. Spine. 1998, 23 (11): 1267-78; discussion 1279. 10.1097\/00007632-199806010-00019.","journal-title":"Spine"},{"issue":"6","key":"305_CR9","doi-asserted-by":"crossref","first-page":"859","DOI":"10.2106\/00004623-199906000-00014","volume":"81","author":"PC McAfee","year":"1999","unstructured":"McAfee PC: Interbody fusion cages in reconstructive operations on the spine. J Bone Joint Surg Am. 1999, 81 (6): 859-880.","journal-title":"J Bone Joint Surg Am"},{"issue":"8","key":"305_CR10","doi-asserted-by":"publisher","first-page":"876","DOI":"10.1097\/00007632-198908000-00019","volume":"14","author":"S Dennis","year":"1989","unstructured":"Dennis S, Watkins R, Landaker S, Dillin W, Springer D: Comparison of disc space heights after anterior lumbar interbody fusion. Spine. 1989, 14 (8): 876-878. 10.1097\/00007632-198908000-00019.","journal-title":"Spine"},{"issue":"5","key":"305_CR11","doi-asserted-by":"publisher","first-page":"634","DOI":"10.1097\/00007632-199803010-00020","volume":"23","author":"BK Weiner","year":"1998","unstructured":"Weiner BK, Fraser RD: Spine update lumbar interbody cages. Spine. 1998, 23 (5): 634-640. 10.1097\/00007632-199803010-00020.","journal-title":"Spine"},{"issue":"4","key":"305_CR12","doi-asserted-by":"publisher","first-page":"328","DOI":"10.1097\/00002517-199808000-00011","volume":"11","author":"MJ Voor","year":"1998","unstructured":"Voor MJ, Mehta S, Wang M, Zhang YM, Mahan J, Johnson JR: Biomechanical evaluation of posterior and anterior lumbar interbody fusion techniques. J Spinal Disord. 1998, 11 (4): 328-334. 10.1097\/00002517-199808000-00011.","journal-title":"J Spinal Disord"},{"issue":"4","key":"305_CR13","doi-asserted-by":"publisher","first-page":"357","DOI":"10.1097\/00002517-199708000-00012","volume":"10","author":"K Nibu","year":"1997","unstructured":"Nibu K, Panjabi MM, Oxland T, Cholewicki J: Multidirectional stabilizing potential of BAK interbody spinal fusion system for anterior surgery. J Spinal Disord. 1997, 10 (4): 357-362. 10.1097\/00002517-199708000-00012.","journal-title":"J Spinal Disord"},{"issue":"2","key":"305_CR14","doi-asserted-by":"publisher","first-page":"351","DOI":"10.1302\/0301-620X.80B2.7693","volume":"80","author":"T Lund","year":"1998","unstructured":"Lund T, Oxland TR, Jost B, Cripton P, Grassmann S, Etter C, Nolte LP: Interbody cage stabilisation in the lumbar spine: biomechanical evaluation of cage design, posterior instrumentation and bone density. J Bone Joint Surg Br. 1998, 80 (2): 351-359. 10.1302\/0301-620X.80B2.7693.","journal-title":"J Bone Joint Surg Br"},{"issue":"22","key":"305_CR15","doi-asserted-by":"publisher","first-page":"2558","DOI":"10.1097\/00007632-199611150-00005","volume":"21","author":"TR Oxland","year":"1996","unstructured":"Oxland TR, Lund T, Jost B, Cripton P, Lippuner K, Jaeger P, Nolte LP: The relative importance of vertebral bone density and disc degeneration in spinal flexibility and interbody implant performance. An in vitro study. Spine. 1996, 21 (22): 2558-2569. 10.1097\/00007632-199611150-00005.","journal-title":"Spine"},{"issue":"23","key":"305_CR16","doi-asserted-by":"publisher","first-page":"2674","DOI":"10.1097\/00007632-200212010-00006","volume":"27","author":"FB Christensen","year":"2002","unstructured":"Christensen FB, Hansen ES, Eiskjaer SP, Hoy K, Helmig P, Neumann P, Niedermann B, Bunger CE: Circumferential lumbar spinal fusion with Brantigan cage versus posterolateral fusion with titanium Cotrel-Dubousset instrumentation: a prospective, randomized clinical study of 146 patients. Spine. 2002, 27 (23): 2674-2683. 10.1097\/00007632-200212010-00006.","journal-title":"Spine"},{"issue":"1","key":"305_CR17","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1097\/00007632-199901010-00005","volume":"24","author":"TO McKinley","year":"1999","unstructured":"McKinley TO, McLain RF, Yerby SA, Sharkey NA, Sarigul-Klijn N, Smith TS: Characteristics of pedicle screw loading. Effect of surgical technique on intravertebral and intrapedicular bending moments. Spine. 1999, 24 (1): 18-24, discussion 25. 10.1097\/00007632-199901010-00005.","journal-title":"Spine"},{"issue":"5","key":"305_CR18","doi-asserted-by":"publisher","first-page":"470","DOI":"10.1097\/00007632-200303010-00011","volume":"28","author":"GR Fogel","year":"2003","unstructured":"Fogel GR, Reitman CA, Liu W, Esses SI: Physical characteristics of polyaxial-headed pedicle screws and biomechanical comparison of load with their failure. Spine. 2003, 28 (5): 470-473. 10.1097\/00007632-200303010-00011.","journal-title":"Spine"},{"issue":"3","key":"305_CR19","doi-asserted-by":"publisher","first-page":"233","DOI":"10.1097\/00024720-200206000-00012","volume":"15","author":"MF Shepard","year":"2002","unstructured":"Shepard MF, Davies MR, Abayan A, Kabo JM, Wang JC: Effects of polyaxial pedicle screws on lumbar construct rigidity. J Spinal Disord Tech. 2002, 15 (3): 233-236.","journal-title":"J Spinal Disord Tech"},{"issue":"4","key":"305_CR20","doi-asserted-by":"publisher","first-page":"367","DOI":"10.1097\/01.BRS.0000092369.50397.85","volume":"29","author":"RE Stanford","year":"2004","unstructured":"Stanford RE, Loefler AH, Stanford PM, Walsh WR: Multiaxial pedicle screw designs: static and dynamic mechanical testing. Spine. 2004, 29 (4): 367-375. 10.1097\/01.BRS.0000092369.50397.85.","journal-title":"Spine"},{"issue":"17","key":"305_CR21","doi-asserted-by":"publisher","first-page":"1893","DOI":"10.1097\/01.brs.0000137067.68630.70","volume":"29","author":"PW Pavlov","year":"2004","unstructured":"Pavlov PW, Meijers H, van Limbeek J, Jacobs WC, Lemmens JA, Obradov-Rajic M, de Kleuver M: Good outcome and restoration of lordosis after anterior lumbar interbody fusion with additional posterior fixation. Spine. 2004, 29 (17): 1893-9; discussion 1900. 10.1097\/01.brs.0000137067.68630.70.","journal-title":"Spine"},{"issue":"12","key":"305_CR22","doi-asserted-by":"publisher","first-page":"1677","DOI":"10.1097\/00007632-199309000-00017","volume":"18","author":"BW Cunningham","year":"1993","unstructured":"Cunningham BW, Sefter JC, Shono Y, McAfee PC: Static and cyclical biomechanical analysis of pedicle screw spinal constructs. Spine. 1993, 18 (12): 1677-1688. 10.1097\/00007632-199309000-00017.","journal-title":"Spine"},{"issue":"11","key":"305_CR23","doi-asserted-by":"crossref","first-page":"1710","DOI":"10.2106\/00004623-199711000-00013","volume":"79","author":"M Kanayama","year":"1997","unstructured":"Kanayama M, Cunningham BW, Weis JC, Parker LM, Kaneda K, McAfee PC: Maturation of the posterolateral spinal fusion and its effect on load-sharing of spinal instrumentation. An in vivo sheep model. J Bone Joint Surg Am. 1997, 79 (11): 1710-1720.","journal-title":"J Bone Joint Surg Am"},{"issue":"1","key":"305_CR24","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1097\/00002517-200002000-00012","volume":"13","author":"DW Polly Jr.","year":"2000","unstructured":"Polly DW, Klemme WR, Cunningham BW, Burnette JB, Haggerty CJ, Oda I: The biomechanical significance of anterior column support in a simulated single-level spinal fusion. J Spinal Disord. 2000, 13 (1): 58-62. 10.1097\/00002517-200002000-00012.","journal-title":"J Spinal Disord"},{"issue":"15","key":"305_CR25","doi-asserted-by":"publisher","first-page":"1899","DOI":"10.1097\/00007632-200008010-00007","volume":"25","author":"A Tsantrizos","year":"2000","unstructured":"Tsantrizos A, Baramki HG, Zeidman S, Steffen T: Segmental stability and compressive strength of posterior lumbar interbody fusion implants. Spine. 2000, 25 (15): 1899-1907. 10.1097\/00007632-200008010-00007.","journal-title":"Spine"},{"issue":"8","key":"305_CR26","doi-asserted-by":"publisher","first-page":"E195","DOI":"10.1097\/01.brs.0000158958.54575.0c","volume":"30","author":"M Takahata","year":"2005","unstructured":"Takahata M, Kotani Y, Abumi K, Ito M, Takada T, Minami A, Kaneda K: An investigational study on the healing process of anterior spinal arthrodesis using a bioactive ceramic spacer and the change in load-sharing of spinal instrumentation. Spine. 2005, 30 (8): E195-203. 10.1097\/01.brs.0000158958.54575.0c.","journal-title":"Spine"},{"issue":"21","key":"305_CR27","doi-asserted-by":"publisher","first-page":"2321","DOI":"10.1097\/00007632-200211010-00004","volume":"27","author":"BW Cunningham","year":"2002","unstructured":"Cunningham BW, Lewis SJ, Long J, Dmitriev AE, Linville DA, Bridwell KH: Biomechanical evaluation of lumbosacral reconstruction techniques for spondylolisthesis: an in vitro porcine model. Spine. 2002, 27 (21): 2321-2327. 10.1097\/00007632-200211010-00004.","journal-title":"Spine"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/1471-2474-8-28.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/1471-2474-8-28\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/1471-2474-8-28","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/1471-2474-8-28.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,8,31]],"date-time":"2021-08-31T22:24:07Z","timestamp":1630448647000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/1471-2474-8-28"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2007,3,10]]},"references-count":27,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2007,12]]}},"alternative-id":["305"],"URL":"https:\/\/doi.org\/10.1186\/1471-2474-8-28","relation":{},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2007,3,10]]},"assertion":[{"value":"24 October 2006","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 March 2007","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 March 2007","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}],"article-number":"28"}}